Cargando…

Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview

This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in...

Descripción completa

Detalles Bibliográficos
Autores principales: Goo, Chui Ling, Tan, Keson Beng Choon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5371219/
https://www.ncbi.nlm.nih.gov/pubmed/28396807
http://dx.doi.org/10.1155/2017/9373818
_version_ 1782518376400158720
author Goo, Chui Ling
Tan, Keson Beng Choon
author_facet Goo, Chui Ling
Tan, Keson Beng Choon
author_sort Goo, Chui Ling
collection PubMed
description This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
format Online
Article
Text
id pubmed-5371219
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-53712192017-04-10 Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview Goo, Chui Ling Tan, Keson Beng Choon Case Rep Dent Case Report This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars. Hindawi 2017 2017-03-15 /pmc/articles/PMC5371219/ /pubmed/28396807 http://dx.doi.org/10.1155/2017/9373818 Text en Copyright © 2017 Chui Ling Goo and Keson Beng Choon Tan. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Goo, Chui Ling
Tan, Keson Beng Choon
Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
title Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
title_full Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
title_fullStr Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
title_full_unstemmed Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
title_short Fabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
title_sort fabricating cad/cam implant-retained mandibular bar overdentures: a clinical and technical overview
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5371219/
https://www.ncbi.nlm.nih.gov/pubmed/28396807
http://dx.doi.org/10.1155/2017/9373818
work_keys_str_mv AT goochuiling fabricatingcadcamimplantretainedmandibularbaroverdenturesaclinicalandtechnicaloverview
AT tankesonbengchoon fabricatingcadcamimplantretainedmandibularbaroverdenturesaclinicalandtechnicaloverview