Cargando…
A Urea Potentiometric Biosensor Based on a Thiophene Copolymer
A potentiometric enzyme biosensor is a convenient detector for quantification of urea concentrations in industrial processes, or for monitoring patients with diabetes, kidney damage or liver malfunction. In this work, poly(3-hexylthiophene-co-3-thiopheneacetic acid) (P(3HT-co-3TAA)) was chemically s...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5371786/ https://www.ncbi.nlm.nih.gov/pubmed/28273816 http://dx.doi.org/10.3390/bios7010013 |
_version_ | 1782518491576795136 |
---|---|
author | Lai, Cheng-Yuan (Kevin) Foot, Peter J. S. Brown, John W. Spearman, Peter |
author_facet | Lai, Cheng-Yuan (Kevin) Foot, Peter J. S. Brown, John W. Spearman, Peter |
author_sort | Lai, Cheng-Yuan (Kevin) |
collection | PubMed |
description | A potentiometric enzyme biosensor is a convenient detector for quantification of urea concentrations in industrial processes, or for monitoring patients with diabetes, kidney damage or liver malfunction. In this work, poly(3-hexylthiophene-co-3-thiopheneacetic acid) (P(3HT-co-3TAA)) was chemically synthesized, characterized and spin-coated onto conductive indium tin oxide (ITO) glass electrodes. Urease (Urs) was covalently attached to the smooth surface of this copolymer via carbodiimide coupling. The electrochemical behavior and stability of the modified Urs/P(3HT-co-3TAA)/ITO glass electrode were investigated by cyclic voltammetry, and the bound enzyme activity was confirmed by spectrophotometry. Potentiometric response studies indicated that this electrode could determine the concentration of urea in aqueous solutions, with a quasi-Nernstian response up to about 5 mM. No attempt was made to optimize the response speed; full equilibration occurred after 10 min, but the half-time for response was typically <1 min. |
format | Online Article Text |
id | pubmed-5371786 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-53717862017-04-10 A Urea Potentiometric Biosensor Based on a Thiophene Copolymer Lai, Cheng-Yuan (Kevin) Foot, Peter J. S. Brown, John W. Spearman, Peter Biosensors (Basel) Article A potentiometric enzyme biosensor is a convenient detector for quantification of urea concentrations in industrial processes, or for monitoring patients with diabetes, kidney damage or liver malfunction. In this work, poly(3-hexylthiophene-co-3-thiopheneacetic acid) (P(3HT-co-3TAA)) was chemically synthesized, characterized and spin-coated onto conductive indium tin oxide (ITO) glass electrodes. Urease (Urs) was covalently attached to the smooth surface of this copolymer via carbodiimide coupling. The electrochemical behavior and stability of the modified Urs/P(3HT-co-3TAA)/ITO glass electrode were investigated by cyclic voltammetry, and the bound enzyme activity was confirmed by spectrophotometry. Potentiometric response studies indicated that this electrode could determine the concentration of urea in aqueous solutions, with a quasi-Nernstian response up to about 5 mM. No attempt was made to optimize the response speed; full equilibration occurred after 10 min, but the half-time for response was typically <1 min. MDPI 2017-03-03 /pmc/articles/PMC5371786/ /pubmed/28273816 http://dx.doi.org/10.3390/bios7010013 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lai, Cheng-Yuan (Kevin) Foot, Peter J. S. Brown, John W. Spearman, Peter A Urea Potentiometric Biosensor Based on a Thiophene Copolymer |
title | A Urea Potentiometric Biosensor Based on a Thiophene Copolymer |
title_full | A Urea Potentiometric Biosensor Based on a Thiophene Copolymer |
title_fullStr | A Urea Potentiometric Biosensor Based on a Thiophene Copolymer |
title_full_unstemmed | A Urea Potentiometric Biosensor Based on a Thiophene Copolymer |
title_short | A Urea Potentiometric Biosensor Based on a Thiophene Copolymer |
title_sort | urea potentiometric biosensor based on a thiophene copolymer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5371786/ https://www.ncbi.nlm.nih.gov/pubmed/28273816 http://dx.doi.org/10.3390/bios7010013 |
work_keys_str_mv | AT laichengyuankevin aureapotentiometricbiosensorbasedonathiophenecopolymer AT footpeterjs aureapotentiometricbiosensorbasedonathiophenecopolymer AT brownjohnw aureapotentiometricbiosensorbasedonathiophenecopolymer AT spearmanpeter aureapotentiometricbiosensorbasedonathiophenecopolymer AT laichengyuankevin ureapotentiometricbiosensorbasedonathiophenecopolymer AT footpeterjs ureapotentiometricbiosensorbasedonathiophenecopolymer AT brownjohnw ureapotentiometricbiosensorbasedonathiophenecopolymer AT spearmanpeter ureapotentiometricbiosensorbasedonathiophenecopolymer |