Cargando…
Corneal densitometry changes in a patient with interface fluid syndrome after small incision lenticule extraction
BACKGROUND: To report a case of interface fluid syndrome (IFS) following small incision lenticule extraction (SMILE) evaluated with corneal densitometry and optical coherence tomography (OCT). CASE PRESENTATION: An 18-year-old man reported sudden vision loss 24 days after SMILE procedure. Intraocula...
Autores principales: | Zheng, Ke, Han, Tian, Li, Meiyan, Han, Yinan, Xu, Ye, Shah, Rupal, Zhou, Xingtao |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5372330/ https://www.ncbi.nlm.nih.gov/pubmed/28356099 http://dx.doi.org/10.1186/s12886-017-0428-0 |
Ejemplares similares
-
The observation during small incision lenticule extraction for myopia with corneal opacity
por: Zhang, Shaowei, et al.
Publicado: (2017) -
Long-term changes in corneal densitometry and associated factors following small incision lenticule extraction for moderate and high myopia
por: Xu, Changqin, et al.
Publicado: (2022) -
Corneal Densitometry After Small Incision Lenticule Extraction (SMILE) and Femtosecond Laser-Assisted LASIK (FS-LASIK): 5-Year Prospective Comparative Study
por: Wei, Ruoyan, et al.
Publicado: (2020) -
Posterior Corneal Elevation after Small Incision Lenticule Extraction for Moderate and High Myopia
por: Zhao, Yu, et al.
Publicado: (2016) -
Intraocular pressure changes and corneal biomechanics after hyperopic small-incision lenticule extraction
por: Fu, Dan, et al.
Publicado: (2020)