Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures

BACKGROUND: Occupational exposures to ultrafine particles in the plume generated during laser hair removal procedures, the most commonly performed light based cosmetic procedure, have not been thoroughly characterized. Acute and chronic exposures to ambient ultrafine particles have been associated w...

Descripción completa

Detalles Bibliográficos
Autores principales: Eshleman, Emily J., LeBlanc, Mallory, Rokoff, Lisa B., Xu, Yinyin, Hu, Rui, Lee, Kachiu, Chuang, Gary S., Adamkiewicz, Gary, Hart, Jaime E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5372340/
https://www.ncbi.nlm.nih.gov/pubmed/28356116
http://dx.doi.org/10.1186/s12940-017-0239-z
_version_ 1782518596813979648
author Eshleman, Emily J.
LeBlanc, Mallory
Rokoff, Lisa B.
Xu, Yinyin
Hu, Rui
Lee, Kachiu
Chuang, Gary S.
Adamkiewicz, Gary
Hart, Jaime E.
author_facet Eshleman, Emily J.
LeBlanc, Mallory
Rokoff, Lisa B.
Xu, Yinyin
Hu, Rui
Lee, Kachiu
Chuang, Gary S.
Adamkiewicz, Gary
Hart, Jaime E.
author_sort Eshleman, Emily J.
collection PubMed
description BACKGROUND: Occupational exposures to ultrafine particles in the plume generated during laser hair removal procedures, the most commonly performed light based cosmetic procedure, have not been thoroughly characterized. Acute and chronic exposures to ambient ultrafine particles have been associated with a number of negative respiratory and cardiovascular health effects. Thus, the aim of this study was to measure airborne concentrations of particles in a diameter size range of 10 nm to 1 μm in procedure rooms during laser hair removal procedures. METHODS: TSI Model 3007 Condensation Particle Counters were used to quantify the particle count concentrations in the waiting and procedure rooms of a dermatology office. Particle concentrations were sampled before, during, and after laser hair removal procedures, and characteristics of each procedure were noted by the performing dermatologist. RESULTS: Twelve procedures were sampled over 4 days. Mean ultrafine particle concentrations in the waiting and procedure rooms were 14,957.4 particles/cm(3) and 22,916.8 particles/cm(3) (p < 0.0001), respectively. Compared to background ultrafine particle concentrations before the procedure, the mean concentration in the procedure room was 2.89 times greater during the procedure (p = 0.009) and 2.09 times greater after the procedure (p = 0.007). Duration of procedure (p = 0.006), body part (p = 0.013), and the use of pre-laser lotion/type of laser (p = 0.039), were the most important predictors of ultrafine particle concentrations. Use of a smoke evacuator (a recommended form of local exhaust ventilation) positioned at 30.5 cm from the source, as opposed to the recommended 1–2 in., lowered particle concentrations, but was not a statistically significant predictor (p = 0.49). CONCLUSIONS: Laser hair removal procedures can generate high exposures to ultrafine particles for dermatologists and other individuals performing laser hair removal, with exposure varying based on multiple determinants.
format Online
Article
Text
id pubmed-5372340
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53723402017-03-31 Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures Eshleman, Emily J. LeBlanc, Mallory Rokoff, Lisa B. Xu, Yinyin Hu, Rui Lee, Kachiu Chuang, Gary S. Adamkiewicz, Gary Hart, Jaime E. Environ Health Research BACKGROUND: Occupational exposures to ultrafine particles in the plume generated during laser hair removal procedures, the most commonly performed light based cosmetic procedure, have not been thoroughly characterized. Acute and chronic exposures to ambient ultrafine particles have been associated with a number of negative respiratory and cardiovascular health effects. Thus, the aim of this study was to measure airborne concentrations of particles in a diameter size range of 10 nm to 1 μm in procedure rooms during laser hair removal procedures. METHODS: TSI Model 3007 Condensation Particle Counters were used to quantify the particle count concentrations in the waiting and procedure rooms of a dermatology office. Particle concentrations were sampled before, during, and after laser hair removal procedures, and characteristics of each procedure were noted by the performing dermatologist. RESULTS: Twelve procedures were sampled over 4 days. Mean ultrafine particle concentrations in the waiting and procedure rooms were 14,957.4 particles/cm(3) and 22,916.8 particles/cm(3) (p < 0.0001), respectively. Compared to background ultrafine particle concentrations before the procedure, the mean concentration in the procedure room was 2.89 times greater during the procedure (p = 0.009) and 2.09 times greater after the procedure (p = 0.007). Duration of procedure (p = 0.006), body part (p = 0.013), and the use of pre-laser lotion/type of laser (p = 0.039), were the most important predictors of ultrafine particle concentrations. Use of a smoke evacuator (a recommended form of local exhaust ventilation) positioned at 30.5 cm from the source, as opposed to the recommended 1–2 in., lowered particle concentrations, but was not a statistically significant predictor (p = 0.49). CONCLUSIONS: Laser hair removal procedures can generate high exposures to ultrafine particles for dermatologists and other individuals performing laser hair removal, with exposure varying based on multiple determinants. BioMed Central 2017-03-29 /pmc/articles/PMC5372340/ /pubmed/28356116 http://dx.doi.org/10.1186/s12940-017-0239-z Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Eshleman, Emily J.
LeBlanc, Mallory
Rokoff, Lisa B.
Xu, Yinyin
Hu, Rui
Lee, Kachiu
Chuang, Gary S.
Adamkiewicz, Gary
Hart, Jaime E.
Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
title Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
title_full Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
title_fullStr Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
title_full_unstemmed Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
title_short Occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
title_sort occupational exposures and determinants of ultrafine particle concentrations during laser hair removal procedures
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5372340/
https://www.ncbi.nlm.nih.gov/pubmed/28356116
http://dx.doi.org/10.1186/s12940-017-0239-z
work_keys_str_mv AT eshlemanemilyj occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT leblancmallory occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT rokofflisab occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT xuyinyin occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT hurui occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT leekachiu occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT chuanggarys occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT adamkiewiczgary occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures
AT hartjaimee occupationalexposuresanddeterminantsofultrafineparticleconcentrationsduringlaserhairremovalprocedures