Cargando…

Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise

Accelerated data acquisition with simultaneous multi-slice (SMS) imaging for functional MRI studies leads to interacting and opposing effects that influence the sensitivity to blood oxygen level-dependent (BOLD) signal changes. Image signal to noise ratio (SNR) is decreased with higher SMS accelerat...

Descripción completa

Detalles Bibliográficos
Autores principales: Todd, Nick, Josephs, Oliver, Zeidman, Peter, Flandin, Guillaume, Moeller, Steen, Weiskopf, Nikolaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5372803/
https://www.ncbi.nlm.nih.gov/pubmed/28424572
http://dx.doi.org/10.3389/fnins.2017.00158
_version_ 1782518693355323392
author Todd, Nick
Josephs, Oliver
Zeidman, Peter
Flandin, Guillaume
Moeller, Steen
Weiskopf, Nikolaus
author_facet Todd, Nick
Josephs, Oliver
Zeidman, Peter
Flandin, Guillaume
Moeller, Steen
Weiskopf, Nikolaus
author_sort Todd, Nick
collection PubMed
description Accelerated data acquisition with simultaneous multi-slice (SMS) imaging for functional MRI studies leads to interacting and opposing effects that influence the sensitivity to blood oxygen level-dependent (BOLD) signal changes. Image signal to noise ratio (SNR) is decreased with higher SMS acceleration factors and shorter repetition times (TR) due to g-factor noise penalties and saturation of longitudinal magnetization. However, the lower image SNR is counteracted by greater statistical power from more samples per unit time and a higher temporal Nyquist frequency that allows for better removal of spurious non-BOLD high frequency signal content. This study investigated the dependence of the BOLD sensitivity on these main driving factors and their interaction, and provides a framework for evaluating optimal acceleration of SMS-EPI sequences. functional magnetic resonance imaging (fMRI) data from a scenes/objects visualization task was acquired in 10 healthy volunteers at a standard neuroscience resolution of 3 mm on a 3T MRI scanner. SMS factors 1, 2, 4, and 8 were used, spanning TRs of 2800 ms to 350 ms. Two data processing methods were used to equalize the number of samples over the SMS factors. BOLD sensitivity was assessed using g-factors maps, temporal SNR (tSNR), and t-score metrics. tSNR results show a dependence on SMS factor that is highly non-uniform over the brain, with outcomes driven by g-factor noise amplification and the presence of high frequency noise. The t-score metrics also show a high degree of spatial dependence: the lower g-factor noise area of V1 shows significant improvements at higher SMS factors; the moderate-level g-factor noise area of the parahippocampal place area shows only a trend of improvement; and the high g-factor noise area of the ventral-medial pre-frontal cortex shows a trend of declining t-scores at higher SMS factors. This spatial variability suggests that the optimal SMS factor for fMRI studies is region dependent. For task fMRI studies done with similar parameters as were used here (3T scanner, 32-channel RF head coil, whole brain coverage at 3 mm isotropic resolution), we recommend SMS accelerations of 4x (conservative) to 8x (aggressive) for most studies and a more conservative acceleration of 2x for studies interested in anterior midline regions.
format Online
Article
Text
id pubmed-5372803
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-53728032017-04-19 Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise Todd, Nick Josephs, Oliver Zeidman, Peter Flandin, Guillaume Moeller, Steen Weiskopf, Nikolaus Front Neurosci Neuroscience Accelerated data acquisition with simultaneous multi-slice (SMS) imaging for functional MRI studies leads to interacting and opposing effects that influence the sensitivity to blood oxygen level-dependent (BOLD) signal changes. Image signal to noise ratio (SNR) is decreased with higher SMS acceleration factors and shorter repetition times (TR) due to g-factor noise penalties and saturation of longitudinal magnetization. However, the lower image SNR is counteracted by greater statistical power from more samples per unit time and a higher temporal Nyquist frequency that allows for better removal of spurious non-BOLD high frequency signal content. This study investigated the dependence of the BOLD sensitivity on these main driving factors and their interaction, and provides a framework for evaluating optimal acceleration of SMS-EPI sequences. functional magnetic resonance imaging (fMRI) data from a scenes/objects visualization task was acquired in 10 healthy volunteers at a standard neuroscience resolution of 3 mm on a 3T MRI scanner. SMS factors 1, 2, 4, and 8 were used, spanning TRs of 2800 ms to 350 ms. Two data processing methods were used to equalize the number of samples over the SMS factors. BOLD sensitivity was assessed using g-factors maps, temporal SNR (tSNR), and t-score metrics. tSNR results show a dependence on SMS factor that is highly non-uniform over the brain, with outcomes driven by g-factor noise amplification and the presence of high frequency noise. The t-score metrics also show a high degree of spatial dependence: the lower g-factor noise area of V1 shows significant improvements at higher SMS factors; the moderate-level g-factor noise area of the parahippocampal place area shows only a trend of improvement; and the high g-factor noise area of the ventral-medial pre-frontal cortex shows a trend of declining t-scores at higher SMS factors. This spatial variability suggests that the optimal SMS factor for fMRI studies is region dependent. For task fMRI studies done with similar parameters as were used here (3T scanner, 32-channel RF head coil, whole brain coverage at 3 mm isotropic resolution), we recommend SMS accelerations of 4x (conservative) to 8x (aggressive) for most studies and a more conservative acceleration of 2x for studies interested in anterior midline regions. Frontiers Media S.A. 2017-03-29 /pmc/articles/PMC5372803/ /pubmed/28424572 http://dx.doi.org/10.3389/fnins.2017.00158 Text en Copyright © 2017 Todd, Josephs, Zeidman, Flandin, Moeller and Weiskopf. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Todd, Nick
Josephs, Oliver
Zeidman, Peter
Flandin, Guillaume
Moeller, Steen
Weiskopf, Nikolaus
Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
title Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
title_full Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
title_fullStr Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
title_full_unstemmed Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
title_short Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise
title_sort functional sensitivity of 2d simultaneous multi-slice echo-planar imaging: effects of acceleration on g-factor and physiological noise
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5372803/
https://www.ncbi.nlm.nih.gov/pubmed/28424572
http://dx.doi.org/10.3389/fnins.2017.00158
work_keys_str_mv AT toddnick functionalsensitivityof2dsimultaneousmultisliceechoplanarimagingeffectsofaccelerationongfactorandphysiologicalnoise
AT josephsoliver functionalsensitivityof2dsimultaneousmultisliceechoplanarimagingeffectsofaccelerationongfactorandphysiologicalnoise
AT zeidmanpeter functionalsensitivityof2dsimultaneousmultisliceechoplanarimagingeffectsofaccelerationongfactorandphysiologicalnoise
AT flandinguillaume functionalsensitivityof2dsimultaneousmultisliceechoplanarimagingeffectsofaccelerationongfactorandphysiologicalnoise
AT moellersteen functionalsensitivityof2dsimultaneousmultisliceechoplanarimagingeffectsofaccelerationongfactorandphysiologicalnoise
AT weiskopfnikolaus functionalsensitivityof2dsimultaneousmultisliceechoplanarimagingeffectsofaccelerationongfactorandphysiologicalnoise