Cargando…

Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)

OBJECTIVES: In the use of activated carbon beds as adsorbents for various types of organic vapor in respirator gas filters, water adsorption of the bed and test gas humidity are expected to alter the accuracy in the estimation of breakthrough data. There is increasing interest in the effects of mois...

Descripción completa

Detalles Bibliográficos
Autores principales: Abiko, Hironobu, Furuse, Mitsuya, Takano, Tsuguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japan Society for Occupational Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5373907/
https://www.ncbi.nlm.nih.gov/pubmed/27725483
_version_ 1782518819198074880
author Abiko, Hironobu
Furuse, Mitsuya
Takano, Tsuguo
author_facet Abiko, Hironobu
Furuse, Mitsuya
Takano, Tsuguo
author_sort Abiko, Hironobu
collection PubMed
description OBJECTIVES: In the use of activated carbon beds as adsorbents for various types of organic vapor in respirator gas filters, water adsorption of the bed and test gas humidity are expected to alter the accuracy in the estimation of breakthrough data. There is increasing interest in the effects of moisture on estimation methods, and this study has investigated the effects with actual breakthrough data. METHODS: We prepared several activated carbon beds preconditioned by equilibration with moisture at different relative humidities (RH=40%-70%) and a constant temperature of 20°C. Then, we measured breakthrough curves in the early region of breakthrough time for 10 types of organic vapor, and investigated the effects of moisture on estimation using the Wheeler-Jonas equation, the simulation software NIOSH MultiVapor™ 2.2.3, and RBT (Relative Breakthrough Time) proposed by Tanaka et al. RESULTS: The Wheeler-Jonas equation showed good accordance with breakthrough curves at all RH in this study. However, the correlation coefficient decreased gradually with increasing RH regardless of type of organic vapor. Estimation of breakthrough time by MultiVapor showed good accordance with experimental data at RH=50%. In contrast, it showed discordance at high RH (>50%). RBTs reported previously were consistent with experimental data at RH=50%. On the other hand, the values of RBT changed markedly with increasing RH. CONCLUSIONS: The results of each estimation method showed good accordance with experimental data under comparatively dry conditions (RH≤50%). However, there were discrepancies under high humidified conditions, and further studies are warranted.
format Online
Article
Text
id pubmed-5373907
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Japan Society for Occupational Health
record_format MEDLINE/PubMed
spelling pubmed-53739072017-04-21 Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time) Abiko, Hironobu Furuse, Mitsuya Takano, Tsuguo J Occup Health Original OBJECTIVES: In the use of activated carbon beds as adsorbents for various types of organic vapor in respirator gas filters, water adsorption of the bed and test gas humidity are expected to alter the accuracy in the estimation of breakthrough data. There is increasing interest in the effects of moisture on estimation methods, and this study has investigated the effects with actual breakthrough data. METHODS: We prepared several activated carbon beds preconditioned by equilibration with moisture at different relative humidities (RH=40%-70%) and a constant temperature of 20°C. Then, we measured breakthrough curves in the early region of breakthrough time for 10 types of organic vapor, and investigated the effects of moisture on estimation using the Wheeler-Jonas equation, the simulation software NIOSH MultiVapor™ 2.2.3, and RBT (Relative Breakthrough Time) proposed by Tanaka et al. RESULTS: The Wheeler-Jonas equation showed good accordance with breakthrough curves at all RH in this study. However, the correlation coefficient decreased gradually with increasing RH regardless of type of organic vapor. Estimation of breakthrough time by MultiVapor showed good accordance with experimental data at RH=50%. In contrast, it showed discordance at high RH (>50%). RBTs reported previously were consistent with experimental data at RH=50%. On the other hand, the values of RBT changed markedly with increasing RH. CONCLUSIONS: The results of each estimation method showed good accordance with experimental data under comparatively dry conditions (RH≤50%). However, there were discrepancies under high humidified conditions, and further studies are warranted. Japan Society for Occupational Health 2016-09-30 2016-11-20 /pmc/articles/PMC5373907/ /pubmed/27725483 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/ Journal of Occupational Health is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Original
Abiko, Hironobu
Furuse, Mitsuya
Takano, Tsuguo
Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
title Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
title_full Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
title_fullStr Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
title_full_unstemmed Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
title_short Estimation of Organic Vapor Breakthrough in Humidified Activated Carbon Beds: -Application of Wheeler-Jonas Equation, NIOSH MultiVapor™ and RBT (Relative Breakthrough Time)
title_sort estimation of organic vapor breakthrough in humidified activated carbon beds: -application of wheeler-jonas equation, niosh multivapor™ and rbt (relative breakthrough time)
topic Original
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5373907/
https://www.ncbi.nlm.nih.gov/pubmed/27725483
work_keys_str_mv AT abikohironobu estimationoforganicvaporbreakthroughinhumidifiedactivatedcarbonbedsapplicationofwheelerjonasequationnioshmultivaporandrbtrelativebreakthroughtime
AT furusemitsuya estimationoforganicvaporbreakthroughinhumidifiedactivatedcarbonbedsapplicationofwheelerjonasequationnioshmultivaporandrbtrelativebreakthroughtime
AT takanotsuguo estimationoforganicvaporbreakthroughinhumidifiedactivatedcarbonbedsapplicationofwheelerjonasequationnioshmultivaporandrbtrelativebreakthroughtime