Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver

AIM: To assess the insulating effect of a poloxamer 407 (P407)-based gel during microwave ablation of liver adjacent to the diaphragm. METHODS: We prepared serial dilutions of P407, and 22.5% (w/w) concentration was identified as suitable for ablation procedures. Subsequently, microwave ablations we...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Li-Li, Xia, Gui-Min, Liu, Yu-Jiang, Dou, Rui, Eisenbrey, John, Liu, Ji-Bin, Wang, Xiao-Wei, Qian, Lin-Xue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5374125/
https://www.ncbi.nlm.nih.gov/pubmed/28405141
http://dx.doi.org/10.3748/wjg.v23.i12.2141
_version_ 1782518834099388416
author Zhang, Li-Li
Xia, Gui-Min
Liu, Yu-Jiang
Dou, Rui
Eisenbrey, John
Liu, Ji-Bin
Wang, Xiao-Wei
Qian, Lin-Xue
author_facet Zhang, Li-Li
Xia, Gui-Min
Liu, Yu-Jiang
Dou, Rui
Eisenbrey, John
Liu, Ji-Bin
Wang, Xiao-Wei
Qian, Lin-Xue
author_sort Zhang, Li-Li
collection PubMed
description AIM: To assess the insulating effect of a poloxamer 407 (P407)-based gel during microwave ablation of liver adjacent to the diaphragm. METHODS: We prepared serial dilutions of P407, and 22.5% (w/w) concentration was identified as suitable for ablation procedures. Subsequently, microwave ablations were performed on the livers of 24 rabbits (gel, saline, control groups, n = 8 in each). The P407 solution and 0.9% normal saline were injected into the potential space between the diaphragm and liver in experimental groups. No barriers were applied to the controls. After microwave ablations, the frequency, size and degree of thermal injury were compared histologically among the three groups. Subsequently, another 8 rabbits were injected with the P407 solution and microwave ablation was performed. The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), blood urea nitrogen (BUN) and creatinine (Cr) in serum were tested at 1 d before microwave ablation and 3 and 7 d after operation. RESULTS: In vivo ablation thermal injury to the adjacent diaphragm was evaluated in the control, saline and 22.5% P407 gel groups (P = 0.001-0.040). However, there was no significant difference in the volume of ablation zone among the three groups (P > 0.05). Moreover, there were no statistical differences among the preoperative and postoperative gel groups according to the levels of ALT, AST, BUN and Cr in serum (all P > 0.05). CONCLUSION: Twenty-two point five percent P407 gel could be a more effective choice during microwave ablation of hepatic tumors adjacent to the diaphragm. Further studies for clinical translation are warranted.
format Online
Article
Text
id pubmed-5374125
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-53741252017-04-12 Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver Zhang, Li-Li Xia, Gui-Min Liu, Yu-Jiang Dou, Rui Eisenbrey, John Liu, Ji-Bin Wang, Xiao-Wei Qian, Lin-Xue World J Gastroenterol Basic Study AIM: To assess the insulating effect of a poloxamer 407 (P407)-based gel during microwave ablation of liver adjacent to the diaphragm. METHODS: We prepared serial dilutions of P407, and 22.5% (w/w) concentration was identified as suitable for ablation procedures. Subsequently, microwave ablations were performed on the livers of 24 rabbits (gel, saline, control groups, n = 8 in each). The P407 solution and 0.9% normal saline were injected into the potential space between the diaphragm and liver in experimental groups. No barriers were applied to the controls. After microwave ablations, the frequency, size and degree of thermal injury were compared histologically among the three groups. Subsequently, another 8 rabbits were injected with the P407 solution and microwave ablation was performed. The levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), blood urea nitrogen (BUN) and creatinine (Cr) in serum were tested at 1 d before microwave ablation and 3 and 7 d after operation. RESULTS: In vivo ablation thermal injury to the adjacent diaphragm was evaluated in the control, saline and 22.5% P407 gel groups (P = 0.001-0.040). However, there was no significant difference in the volume of ablation zone among the three groups (P > 0.05). Moreover, there were no statistical differences among the preoperative and postoperative gel groups according to the levels of ALT, AST, BUN and Cr in serum (all P > 0.05). CONCLUSION: Twenty-two point five percent P407 gel could be a more effective choice during microwave ablation of hepatic tumors adjacent to the diaphragm. Further studies for clinical translation are warranted. Baishideng Publishing Group Inc 2017-03-28 2017-03-28 /pmc/articles/PMC5374125/ /pubmed/28405141 http://dx.doi.org/10.3748/wjg.v23.i12.2141 Text en ©The Author(s) 2017. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Basic Study
Zhang, Li-Li
Xia, Gui-Min
Liu, Yu-Jiang
Dou, Rui
Eisenbrey, John
Liu, Ji-Bin
Wang, Xiao-Wei
Qian, Lin-Xue
Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
title Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
title_full Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
title_fullStr Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
title_full_unstemmed Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
title_short Effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
title_sort effect of a poloxamer 407-based thermosensitive gel on minimization of thermal injury to diaphragm during microwave ablation of the liver
topic Basic Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5374125/
https://www.ncbi.nlm.nih.gov/pubmed/28405141
http://dx.doi.org/10.3748/wjg.v23.i12.2141
work_keys_str_mv AT zhanglili effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT xiaguimin effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT liuyujiang effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT dourui effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT eisenbreyjohn effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT liujibin effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT wangxiaowei effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver
AT qianlinxue effectofapoloxamer407basedthermosensitivegelonminimizationofthermalinjurytodiaphragmduringmicrowaveablationoftheliver