Cargando…

Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles

A ratiometric optical sensor has been developed with electrospinning processing method for dissolved oxygen measurement. The sensing film is fabricated by using silver nano-particles (Ag NPs) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) dichloride complex (Ru(DPP)(3)Cl(2)) encapsu...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Zike, Yu, Xinsheng, Zhai, Shikui, Hao, Yingyan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375834/
https://www.ncbi.nlm.nih.gov/pubmed/28282946
http://dx.doi.org/10.3390/s17030548
_version_ 1782519067074101248
author Jiang, Zike
Yu, Xinsheng
Zhai, Shikui
Hao, Yingyan
author_facet Jiang, Zike
Yu, Xinsheng
Zhai, Shikui
Hao, Yingyan
author_sort Jiang, Zike
collection PubMed
description A ratiometric optical sensor has been developed with electrospinning processing method for dissolved oxygen measurement. The sensing film is fabricated by using silver nano-particles (Ag NPs) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) dichloride complex (Ru(DPP)(3)Cl(2)) encapsulated in plasticized polymethyl methacrylate (PMMA). An insensitive 3-(2-benzothiazolyl)-7-(diethy lamino)-(6CI,7CI) (Coumarin6) is adopted as reference. The ratio of oxygenation is calculated at each image pixel of a 3CCD camera to quantify the oxygen concentration in aqueous environment. Compared to Ag-free film, the response time of Ag-containing films were improved from 1.5 s to 1.0 s upon switching from deoxygenated to air saturation and from 65 s to 45 s from air saturation to fully deoxygenated. The response times of the Ag-free film obtained by knifing was 2.0 s upon switching from deoxygenated to air saturation and 104 s from air saturation to fully deoxygenated. Results of the evaluation of accuracy, limit of detection, stability, and photostability are presented. An experiment measuring the spatiotemporal variation of oxygen distribution within the photosynthesis and respiration of Chlorella vulgaris is demonstrated. It is shown that the nanofiber-based optical sensor film could serve as a promising method for rapid oxygen monitoring in aqueous applications.
format Online
Article
Text
id pubmed-5375834
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-53758342017-04-10 Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles Jiang, Zike Yu, Xinsheng Zhai, Shikui Hao, Yingyan Sensors (Basel) Article A ratiometric optical sensor has been developed with electrospinning processing method for dissolved oxygen measurement. The sensing film is fabricated by using silver nano-particles (Ag NPs) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) dichloride complex (Ru(DPP)(3)Cl(2)) encapsulated in plasticized polymethyl methacrylate (PMMA). An insensitive 3-(2-benzothiazolyl)-7-(diethy lamino)-(6CI,7CI) (Coumarin6) is adopted as reference. The ratio of oxygenation is calculated at each image pixel of a 3CCD camera to quantify the oxygen concentration in aqueous environment. Compared to Ag-free film, the response time of Ag-containing films were improved from 1.5 s to 1.0 s upon switching from deoxygenated to air saturation and from 65 s to 45 s from air saturation to fully deoxygenated. The response times of the Ag-free film obtained by knifing was 2.0 s upon switching from deoxygenated to air saturation and 104 s from air saturation to fully deoxygenated. Results of the evaluation of accuracy, limit of detection, stability, and photostability are presented. An experiment measuring the spatiotemporal variation of oxygen distribution within the photosynthesis and respiration of Chlorella vulgaris is demonstrated. It is shown that the nanofiber-based optical sensor film could serve as a promising method for rapid oxygen monitoring in aqueous applications. MDPI 2017-03-09 /pmc/articles/PMC5375834/ /pubmed/28282946 http://dx.doi.org/10.3390/s17030548 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jiang, Zike
Yu, Xinsheng
Zhai, Shikui
Hao, Yingyan
Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles
title Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles
title_full Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles
title_fullStr Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles
title_full_unstemmed Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles
title_short Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles
title_sort ratiometric dissolved oxygen sensors based on ruthenium complex doped with silver nanoparticles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375834/
https://www.ncbi.nlm.nih.gov/pubmed/28282946
http://dx.doi.org/10.3390/s17030548
work_keys_str_mv AT jiangzike ratiometricdissolvedoxygensensorsbasedonrutheniumcomplexdopedwithsilvernanoparticles
AT yuxinsheng ratiometricdissolvedoxygensensorsbasedonrutheniumcomplexdopedwithsilvernanoparticles
AT zhaishikui ratiometricdissolvedoxygensensorsbasedonrutheniumcomplexdopedwithsilvernanoparticles
AT haoyingyan ratiometricdissolvedoxygensensorsbasedonrutheniumcomplexdopedwithsilvernanoparticles