Cargando…

Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors

Quantitative evaluation of motor function is of great demand for monitoring clinical outcome of applied interventions and further guiding the establishment of therapeutic protocol. This study proposes a novel framework for evaluating upper limb motor function based on data fusion from inertial measu...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yanran, Zhang, Xu, Gong, Yanan, Cheng, Ying, Gao, Xiaoping, Chen, Xiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375868/
https://www.ncbi.nlm.nih.gov/pubmed/28335394
http://dx.doi.org/10.3390/s17030582
_version_ 1782519074554642432
author Li, Yanran
Zhang, Xu
Gong, Yanan
Cheng, Ying
Gao, Xiaoping
Chen, Xiang
author_facet Li, Yanran
Zhang, Xu
Gong, Yanan
Cheng, Ying
Gao, Xiaoping
Chen, Xiang
author_sort Li, Yanran
collection PubMed
description Quantitative evaluation of motor function is of great demand for monitoring clinical outcome of applied interventions and further guiding the establishment of therapeutic protocol. This study proposes a novel framework for evaluating upper limb motor function based on data fusion from inertial measurement units (IMUs) and surface electromyography (EMG) sensors. With wearable sensors worn on the tested upper limbs, subjects were asked to perform eleven straightforward, specifically designed canonical upper-limb functional tasks. A series of machine learning algorithms were applied to the recorded motion data to produce evaluation indicators, which is able to reflect the level of upper-limb motor function abnormality. Sixteen healthy subjects and eighteen stroke subjects with substantial hemiparesis were recruited in the experiment. The combined IMU and EMG data yielded superior performance over the IMU data alone and the EMG data alone, in terms of decreased normal data variation rate (NDVR) and improved determination coefficient (DC) from a regression analysis between the derived indicator and routine clinical assessment score. Three common unsupervised learning algorithms achieved comparable performance with NDVR around 10% and strong DC around 0.85. By contrast, the use of a supervised algorithm was able to dramatically decrease the NDVR to 6.55%. With the proposed framework, all the produced indicators demonstrated high agreement with the routine clinical assessment scale, indicating their capability of assessing upper-limb motor functions. This study offers a feasible solution to motor function assessment in an objective and quantitative manner, especially suitable for home and community use.
format Online
Article
Text
id pubmed-5375868
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-53758682017-04-10 Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors Li, Yanran Zhang, Xu Gong, Yanan Cheng, Ying Gao, Xiaoping Chen, Xiang Sensors (Basel) Article Quantitative evaluation of motor function is of great demand for monitoring clinical outcome of applied interventions and further guiding the establishment of therapeutic protocol. This study proposes a novel framework for evaluating upper limb motor function based on data fusion from inertial measurement units (IMUs) and surface electromyography (EMG) sensors. With wearable sensors worn on the tested upper limbs, subjects were asked to perform eleven straightforward, specifically designed canonical upper-limb functional tasks. A series of machine learning algorithms were applied to the recorded motion data to produce evaluation indicators, which is able to reflect the level of upper-limb motor function abnormality. Sixteen healthy subjects and eighteen stroke subjects with substantial hemiparesis were recruited in the experiment. The combined IMU and EMG data yielded superior performance over the IMU data alone and the EMG data alone, in terms of decreased normal data variation rate (NDVR) and improved determination coefficient (DC) from a regression analysis between the derived indicator and routine clinical assessment score. Three common unsupervised learning algorithms achieved comparable performance with NDVR around 10% and strong DC around 0.85. By contrast, the use of a supervised algorithm was able to dramatically decrease the NDVR to 6.55%. With the proposed framework, all the produced indicators demonstrated high agreement with the routine clinical assessment scale, indicating their capability of assessing upper-limb motor functions. This study offers a feasible solution to motor function assessment in an objective and quantitative manner, especially suitable for home and community use. MDPI 2017-03-13 /pmc/articles/PMC5375868/ /pubmed/28335394 http://dx.doi.org/10.3390/s17030582 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Yanran
Zhang, Xu
Gong, Yanan
Cheng, Ying
Gao, Xiaoping
Chen, Xiang
Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
title Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
title_full Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
title_fullStr Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
title_full_unstemmed Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
title_short Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
title_sort motor function evaluation of hemiplegic upper-extremities using data fusion from wearable inertial and surface emg sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375868/
https://www.ncbi.nlm.nih.gov/pubmed/28335394
http://dx.doi.org/10.3390/s17030582
work_keys_str_mv AT liyanran motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors
AT zhangxu motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors
AT gongyanan motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors
AT chengying motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors
AT gaoxiaoping motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors
AT chenxiang motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors