Cargando…
Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors
Quantitative evaluation of motor function is of great demand for monitoring clinical outcome of applied interventions and further guiding the establishment of therapeutic protocol. This study proposes a novel framework for evaluating upper limb motor function based on data fusion from inertial measu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375868/ https://www.ncbi.nlm.nih.gov/pubmed/28335394 http://dx.doi.org/10.3390/s17030582 |
_version_ | 1782519074554642432 |
---|---|
author | Li, Yanran Zhang, Xu Gong, Yanan Cheng, Ying Gao, Xiaoping Chen, Xiang |
author_facet | Li, Yanran Zhang, Xu Gong, Yanan Cheng, Ying Gao, Xiaoping Chen, Xiang |
author_sort | Li, Yanran |
collection | PubMed |
description | Quantitative evaluation of motor function is of great demand for monitoring clinical outcome of applied interventions and further guiding the establishment of therapeutic protocol. This study proposes a novel framework for evaluating upper limb motor function based on data fusion from inertial measurement units (IMUs) and surface electromyography (EMG) sensors. With wearable sensors worn on the tested upper limbs, subjects were asked to perform eleven straightforward, specifically designed canonical upper-limb functional tasks. A series of machine learning algorithms were applied to the recorded motion data to produce evaluation indicators, which is able to reflect the level of upper-limb motor function abnormality. Sixteen healthy subjects and eighteen stroke subjects with substantial hemiparesis were recruited in the experiment. The combined IMU and EMG data yielded superior performance over the IMU data alone and the EMG data alone, in terms of decreased normal data variation rate (NDVR) and improved determination coefficient (DC) from a regression analysis between the derived indicator and routine clinical assessment score. Three common unsupervised learning algorithms achieved comparable performance with NDVR around 10% and strong DC around 0.85. By contrast, the use of a supervised algorithm was able to dramatically decrease the NDVR to 6.55%. With the proposed framework, all the produced indicators demonstrated high agreement with the routine clinical assessment scale, indicating their capability of assessing upper-limb motor functions. This study offers a feasible solution to motor function assessment in an objective and quantitative manner, especially suitable for home and community use. |
format | Online Article Text |
id | pubmed-5375868 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-53758682017-04-10 Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors Li, Yanran Zhang, Xu Gong, Yanan Cheng, Ying Gao, Xiaoping Chen, Xiang Sensors (Basel) Article Quantitative evaluation of motor function is of great demand for monitoring clinical outcome of applied interventions and further guiding the establishment of therapeutic protocol. This study proposes a novel framework for evaluating upper limb motor function based on data fusion from inertial measurement units (IMUs) and surface electromyography (EMG) sensors. With wearable sensors worn on the tested upper limbs, subjects were asked to perform eleven straightforward, specifically designed canonical upper-limb functional tasks. A series of machine learning algorithms were applied to the recorded motion data to produce evaluation indicators, which is able to reflect the level of upper-limb motor function abnormality. Sixteen healthy subjects and eighteen stroke subjects with substantial hemiparesis were recruited in the experiment. The combined IMU and EMG data yielded superior performance over the IMU data alone and the EMG data alone, in terms of decreased normal data variation rate (NDVR) and improved determination coefficient (DC) from a regression analysis between the derived indicator and routine clinical assessment score. Three common unsupervised learning algorithms achieved comparable performance with NDVR around 10% and strong DC around 0.85. By contrast, the use of a supervised algorithm was able to dramatically decrease the NDVR to 6.55%. With the proposed framework, all the produced indicators demonstrated high agreement with the routine clinical assessment scale, indicating their capability of assessing upper-limb motor functions. This study offers a feasible solution to motor function assessment in an objective and quantitative manner, especially suitable for home and community use. MDPI 2017-03-13 /pmc/articles/PMC5375868/ /pubmed/28335394 http://dx.doi.org/10.3390/s17030582 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Li, Yanran Zhang, Xu Gong, Yanan Cheng, Ying Gao, Xiaoping Chen, Xiang Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors |
title | Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors |
title_full | Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors |
title_fullStr | Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors |
title_full_unstemmed | Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors |
title_short | Motor Function Evaluation of Hemiplegic Upper-Extremities Using Data Fusion from Wearable Inertial and Surface EMG Sensors |
title_sort | motor function evaluation of hemiplegic upper-extremities using data fusion from wearable inertial and surface emg sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5375868/ https://www.ncbi.nlm.nih.gov/pubmed/28335394 http://dx.doi.org/10.3390/s17030582 |
work_keys_str_mv | AT liyanran motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors AT zhangxu motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors AT gongyanan motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors AT chengying motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors AT gaoxiaoping motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors AT chenxiang motorfunctionevaluationofhemiplegicupperextremitiesusingdatafusionfromwearableinertialandsurfaceemgsensors |