Cargando…

A case report of distal radioulnar joint dislocation fixed by using mini-plate-button

INTRODUCTION: Pathological factors may cause significant distal radioulnar joint (DRUJ) dislocation, which is a rare clinical entity in orthopedic literature, and corresponding treatments are not uniform. PRESENTATION OF CASE: We describe the case of a DRUJ dislocation caused by giant cell tumour of...

Descripción completa

Detalles Bibliográficos
Autores principales: Sang, Lili, Liu, Hongliang, Liu, Jian, Chen, Bojian, Xu, Shuchai
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5377428/
https://www.ncbi.nlm.nih.gov/pubmed/28371634
http://dx.doi.org/10.1016/j.ijscr.2017.02.042
_version_ 1782519315703005184
author Sang, Lili
Liu, Hongliang
Liu, Jian
Chen, Bojian
Xu, Shuchai
author_facet Sang, Lili
Liu, Hongliang
Liu, Jian
Chen, Bojian
Xu, Shuchai
author_sort Sang, Lili
collection PubMed
description INTRODUCTION: Pathological factors may cause significant distal radioulnar joint (DRUJ) dislocation, which is a rare clinical entity in orthopedic literature, and corresponding treatments are not uniform. PRESENTATION OF CASE: We describe the case of a DRUJ dislocation caused by giant cell tumour of tendon sheath (GCTTS) in wrist. At surgery, the stabilization of DRUJ was constructed by using mini-plate-button after removal of intraoperative removal of the tumor. Postoperative plain films showed good position, and no obvious dislocation was found. DISCUSSION: Reduction of DRUJ dislocation was facilitated by mini-plate-button and absorbable suture. The treatment avoided intro-articular or extra-articular ligament construction and damage of adjacent tissue and bone. CONCLUSION: For DRUJ dislocation caused by GCTTS leading to severe tendon and ligament damage, the operative treatment of mini-plate-button may be effective.
format Online
Article
Text
id pubmed-5377428
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-53774282017-04-07 A case report of distal radioulnar joint dislocation fixed by using mini-plate-button Sang, Lili Liu, Hongliang Liu, Jian Chen, Bojian Xu, Shuchai Int J Surg Case Rep Case Report INTRODUCTION: Pathological factors may cause significant distal radioulnar joint (DRUJ) dislocation, which is a rare clinical entity in orthopedic literature, and corresponding treatments are not uniform. PRESENTATION OF CASE: We describe the case of a DRUJ dislocation caused by giant cell tumour of tendon sheath (GCTTS) in wrist. At surgery, the stabilization of DRUJ was constructed by using mini-plate-button after removal of intraoperative removal of the tumor. Postoperative plain films showed good position, and no obvious dislocation was found. DISCUSSION: Reduction of DRUJ dislocation was facilitated by mini-plate-button and absorbable suture. The treatment avoided intro-articular or extra-articular ligament construction and damage of adjacent tissue and bone. CONCLUSION: For DRUJ dislocation caused by GCTTS leading to severe tendon and ligament damage, the operative treatment of mini-plate-button may be effective. Elsevier 2017-02-24 /pmc/articles/PMC5377428/ /pubmed/28371634 http://dx.doi.org/10.1016/j.ijscr.2017.02.042 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Sang, Lili
Liu, Hongliang
Liu, Jian
Chen, Bojian
Xu, Shuchai
A case report of distal radioulnar joint dislocation fixed by using mini-plate-button
title A case report of distal radioulnar joint dislocation fixed by using mini-plate-button
title_full A case report of distal radioulnar joint dislocation fixed by using mini-plate-button
title_fullStr A case report of distal radioulnar joint dislocation fixed by using mini-plate-button
title_full_unstemmed A case report of distal radioulnar joint dislocation fixed by using mini-plate-button
title_short A case report of distal radioulnar joint dislocation fixed by using mini-plate-button
title_sort case report of distal radioulnar joint dislocation fixed by using mini-plate-button
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5377428/
https://www.ncbi.nlm.nih.gov/pubmed/28371634
http://dx.doi.org/10.1016/j.ijscr.2017.02.042
work_keys_str_mv AT sanglili acasereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT liuhongliang acasereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT liujian acasereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT chenbojian acasereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT xushuchai acasereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT sanglili casereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT liuhongliang casereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT liujian casereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT chenbojian casereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton
AT xushuchai casereportofdistalradioulnarjointdislocationfixedbyusingminiplatebutton