Cargando…

Safety and Efficacy of an Aortic Arch Stent Graft with Window-Shaped Fenestration for Supra-Aortic Arch Vessels: an Experimental Study in Swine

BACKGROUND AND OBJECTIVES: Thoracic endovascular aortic repair exhibits limitations in cases where the aortic pathology involves the aortic arch. We had already developed a fenestrated aortic stent graft (FASG) with a preloaded catheter for aortic pathology involving the aortic arch. FASG was suitab...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jong Ha, Lee, Han Cheol, Choe, Jeong Cheon, Kim, Sang-Pil, Park, Tae Sik, Ahn, Jinhee, Park, Jin Sup, Lee, Hye Won, Oh, Jun-Hyok, Choi, Jung Hyun, Cha, Kwang Soo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5378028/
https://www.ncbi.nlm.nih.gov/pubmed/28382077
http://dx.doi.org/10.4070/kcj.2016.0286
Descripción
Sumario:BACKGROUND AND OBJECTIVES: Thoracic endovascular aortic repair exhibits limitations in cases where the aortic pathology involves the aortic arch. We had already developed a fenestrated aortic stent graft (FASG) with a preloaded catheter for aortic pathology involving the aortic arch. FASG was suitable for elective cases. MATERIALS AND METHODS: An aortic arch stent graft with a window-shaped fenestration (FASG-W) for supra-aortic arch vessels is suitable for emergent cases. This study aims to test a FASG-W for supra-aortic arch vessels and to perform a preclinical study in swine to evaluate the safety and efficacy of this device. Six FASG-Ws with 1 preloaded catheter were advanced through the iliac artery in 6 swine. The presence of endoleak and the patency and deformity of the grafts were examined with computed tomography (CT) at 4 weeks postoperatively. A postmortem examination was performed at 8 weeks. The mean procedure time for FASG-W was 27.15±4.02 minutes. The mean time for the selection of the right carotid artery was 5.72±0.72 minutes. RESULTS: Major adverse events were not observed in any of the 6 pigs who survived for 8 weeks. For the FASG-W, no endoleaks, no disconnection, and no occlusion of the stent grafts were observed in the CT findings or the postmortem gross findings. CONCLUSION: The procedure with the FASG-W was able to be performed safely in a relatively short procedure time and involved an easy technique. The FASG-W was found to be safe and convenient for use in this preclinical study of swine.