Cargando…

Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement

BACKGROUND: Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, duri...

Descripción completa

Detalles Bibliográficos
Autores principales: Benmira, Amir M., Perez-Martin, Antonia, Coudray, Sarah, Schuster, Iris, Aichoun, Isabelle, Laurent, Jérémy, Bereski-Reguig, Fethi, Dauzat, Michel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5378056/
https://www.ncbi.nlm.nih.gov/pubmed/28099195
http://dx.doi.org/10.1097/HJH.0000000000001252
_version_ 1782519397800214528
author Benmira, Amir M.
Perez-Martin, Antonia
Coudray, Sarah
Schuster, Iris
Aichoun, Isabelle
Laurent, Jérémy
Bereski-Reguig, Fethi
Dauzat, Michel
author_facet Benmira, Amir M.
Perez-Martin, Antonia
Coudray, Sarah
Schuster, Iris
Aichoun, Isabelle
Laurent, Jérémy
Bereski-Reguig, Fethi
Dauzat, Michel
author_sort Benmira, Amir M.
collection PubMed
description BACKGROUND: Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, during pneumatic cuff deflation, the time interval from the foot to the apex of the systolic peak of the oscillometric signal, which reaches a maximum concomitant with the first Korotkoff sound. METHOD: In 145 study participants and patients (group 1), we measured the systolic brachial artery blood pressure by Korotkoff sound recording, conventional oscillometry, and our fully automated systolic peak foot-to-apex time interval (SFATI) technique. In 35 other patients (group 2), we compared SFATI with intra-arterial measurement. RESULTS: In group 1, the concordance correlation coefficient was 0.989 and 0.984 between SFATI and Korotkoff sounds, 0.884 and 0.917 between oscillometry and Korotkoff sounds, and 0.882 and 0.919 between SFATI and oscillometry, respectively, on the left and right arm. In group 2, it was 0.72 between SFATI and intra-arterial measurement, 0.67 between oscillometry and intra-arterial measurement, and 0.92 between SFATI and Korotkoff sounds. In 40 study participants, the reproducibility study yielded a concordance coefficient of 0.95 for SFATI and 0.94 for Korotkoff sounds. CONCLUSION: SFATI BP measurement shows an excellent concordance with the auscultatory technique, offering a major improvement over current oscillometric techniques and allowing standardization.
format Online
Article
Text
id pubmed-5378056
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-53780562017-04-07 Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement Benmira, Amir M. Perez-Martin, Antonia Coudray, Sarah Schuster, Iris Aichoun, Isabelle Laurent, Jérémy Bereski-Reguig, Fethi Dauzat, Michel J Hypertens ORIGINAL PAPERS: BP measurement BACKGROUND: Noninvasive blood pressure (BP) measurement is essential for the study of human physiology but automatic oscillometric devices only estimate SBP and DBP using various, undisclosed algorithms, precluding standardization and interchangeability. We propose a novel approach by tracking, during pneumatic cuff deflation, the time interval from the foot to the apex of the systolic peak of the oscillometric signal, which reaches a maximum concomitant with the first Korotkoff sound. METHOD: In 145 study participants and patients (group 1), we measured the systolic brachial artery blood pressure by Korotkoff sound recording, conventional oscillometry, and our fully automated systolic peak foot-to-apex time interval (SFATI) technique. In 35 other patients (group 2), we compared SFATI with intra-arterial measurement. RESULTS: In group 1, the concordance correlation coefficient was 0.989 and 0.984 between SFATI and Korotkoff sounds, 0.884 and 0.917 between oscillometry and Korotkoff sounds, and 0.882 and 0.919 between SFATI and oscillometry, respectively, on the left and right arm. In group 2, it was 0.72 between SFATI and intra-arterial measurement, 0.67 between oscillometry and intra-arterial measurement, and 0.92 between SFATI and Korotkoff sounds. In 40 study participants, the reproducibility study yielded a concordance coefficient of 0.95 for SFATI and 0.94 for Korotkoff sounds. CONCLUSION: SFATI BP measurement shows an excellent concordance with the auscultatory technique, offering a major improvement over current oscillometric techniques and allowing standardization. Lippincott Williams & Wilkins 2017-05 2017-01-17 /pmc/articles/PMC5378056/ /pubmed/28099195 http://dx.doi.org/10.1097/HJH.0000000000001252 Text en Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle ORIGINAL PAPERS: BP measurement
Benmira, Amir M.
Perez-Martin, Antonia
Coudray, Sarah
Schuster, Iris
Aichoun, Isabelle
Laurent, Jérémy
Bereski-Reguig, Fethi
Dauzat, Michel
Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
title Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
title_full Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
title_fullStr Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
title_full_unstemmed Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
title_short Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
title_sort systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement
topic ORIGINAL PAPERS: BP measurement
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5378056/
https://www.ncbi.nlm.nih.gov/pubmed/28099195
http://dx.doi.org/10.1097/HJH.0000000000001252
work_keys_str_mv AT benmiraamirm systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT perezmartinantonia systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT coudraysarah systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT schusteriris systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT aichounisabelle systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT laurentjeremy systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT bereskireguigfethi systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement
AT dauzatmichel systolicpeakfoottoapextimeintervalanoveloscillometrictechniqueforsystolicbloodpressuremeasurement