Cargando…

A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis

BACKGROUND: Pre-produced bicarbonate concentrates (PPC) are still widely used in developing countries despite its cost and risk but Central Concentrate System (CCS) is lacking in data to support its wider adoption. METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machine...

Descripción completa

Detalles Bibliográficos
Autores principales: Fauziah, K., Go, K. W., Ghazali, A., Zaki, M., Lim, T. O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5379768/
https://www.ncbi.nlm.nih.gov/pubmed/28372556
http://dx.doi.org/10.1186/s12882-017-0537-2
_version_ 1782519674391494656
author Fauziah, K.
Go, K. W.
Ghazali, A.
Zaki, M.
Lim, T. O.
author_facet Fauziah, K.
Go, K. W.
Ghazali, A.
Zaki, M.
Lim, T. O.
author_sort Fauziah, K.
collection PubMed
description BACKGROUND: Pre-produced bicarbonate concentrates (PPC) are still widely used in developing countries despite its cost and risk but Central Concentrate System (CCS) is lacking in data to support its wider adoption. METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machines to compare CCS versus PPC. Performance is assessed by solute concentrations while safety is assessed by microbial count, endotoxin level and adverse event reporting. RESULTS: Microbial counts and endotoxin levels were monitored on 48 occasions during the 8-week study for the CCS arm of the study. The levels were all below the action limit during the study. No patient reported any adverse events. Dialysate Sodium, Chloride and Bicarbonate concentrations were measured on a total of 128 occasions for each arm of the study. The relative deviations of Sodium, Chloride and Bicarbonate concentration were within ±5% of their nominal values for both. The 95% Confidence Intervals for the ratio of the mean solute concentrations on the CCS to PPC lie within the tolerance limit of ±5%. CONCLUSION: Modern CCS is bacteriologically safe and its performance statistically equivalent to PPC.
format Online
Article
Text
id pubmed-5379768
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53797682017-04-10 A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis Fauziah, K. Go, K. W. Ghazali, A. Zaki, M. Lim, T. O. BMC Nephrol Research Article BACKGROUND: Pre-produced bicarbonate concentrates (PPC) are still widely used in developing countries despite its cost and risk but Central Concentrate System (CCS) is lacking in data to support its wider adoption. METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machines to compare CCS versus PPC. Performance is assessed by solute concentrations while safety is assessed by microbial count, endotoxin level and adverse event reporting. RESULTS: Microbial counts and endotoxin levels were monitored on 48 occasions during the 8-week study for the CCS arm of the study. The levels were all below the action limit during the study. No patient reported any adverse events. Dialysate Sodium, Chloride and Bicarbonate concentrations were measured on a total of 128 occasions for each arm of the study. The relative deviations of Sodium, Chloride and Bicarbonate concentration were within ±5% of their nominal values for both. The 95% Confidence Intervals for the ratio of the mean solute concentrations on the CCS to PPC lie within the tolerance limit of ±5%. CONCLUSION: Modern CCS is bacteriologically safe and its performance statistically equivalent to PPC. BioMed Central 2017-04-03 /pmc/articles/PMC5379768/ /pubmed/28372556 http://dx.doi.org/10.1186/s12882-017-0537-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Fauziah, K.
Go, K. W.
Ghazali, A.
Zaki, M.
Lim, T. O.
A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
title A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
title_full A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
title_fullStr A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
title_full_unstemmed A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
title_short A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
title_sort randomized cross-over study comparing the performance of hd integra™ central concentrate system versus pre-produced concentrate in hemodialysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5379768/
https://www.ncbi.nlm.nih.gov/pubmed/28372556
http://dx.doi.org/10.1186/s12882-017-0537-2
work_keys_str_mv AT fauziahk arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT gokw arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT ghazalia arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT zakim arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT limto arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT fauziahk randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT gokw randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT ghazalia randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT zakim randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis
AT limto randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis