Cargando…
A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis
BACKGROUND: Pre-produced bicarbonate concentrates (PPC) are still widely used in developing countries despite its cost and risk but Central Concentrate System (CCS) is lacking in data to support its wider adoption. METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machine...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5379768/ https://www.ncbi.nlm.nih.gov/pubmed/28372556 http://dx.doi.org/10.1186/s12882-017-0537-2 |
_version_ | 1782519674391494656 |
---|---|
author | Fauziah, K. Go, K. W. Ghazali, A. Zaki, M. Lim, T. O. |
author_facet | Fauziah, K. Go, K. W. Ghazali, A. Zaki, M. Lim, T. O. |
author_sort | Fauziah, K. |
collection | PubMed |
description | BACKGROUND: Pre-produced bicarbonate concentrates (PPC) are still widely used in developing countries despite its cost and risk but Central Concentrate System (CCS) is lacking in data to support its wider adoption. METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machines to compare CCS versus PPC. Performance is assessed by solute concentrations while safety is assessed by microbial count, endotoxin level and adverse event reporting. RESULTS: Microbial counts and endotoxin levels were monitored on 48 occasions during the 8-week study for the CCS arm of the study. The levels were all below the action limit during the study. No patient reported any adverse events. Dialysate Sodium, Chloride and Bicarbonate concentrations were measured on a total of 128 occasions for each arm of the study. The relative deviations of Sodium, Chloride and Bicarbonate concentration were within ±5% of their nominal values for both. The 95% Confidence Intervals for the ratio of the mean solute concentrations on the CCS to PPC lie within the tolerance limit of ±5%. CONCLUSION: Modern CCS is bacteriologically safe and its performance statistically equivalent to PPC. |
format | Online Article Text |
id | pubmed-5379768 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-53797682017-04-10 A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis Fauziah, K. Go, K. W. Ghazali, A. Zaki, M. Lim, T. O. BMC Nephrol Research Article BACKGROUND: Pre-produced bicarbonate concentrates (PPC) are still widely used in developing countries despite its cost and risk but Central Concentrate System (CCS) is lacking in data to support its wider adoption. METHODS: We conducted an 8-week randomized crossover study on 16 Hemodialysis machines to compare CCS versus PPC. Performance is assessed by solute concentrations while safety is assessed by microbial count, endotoxin level and adverse event reporting. RESULTS: Microbial counts and endotoxin levels were monitored on 48 occasions during the 8-week study for the CCS arm of the study. The levels were all below the action limit during the study. No patient reported any adverse events. Dialysate Sodium, Chloride and Bicarbonate concentrations were measured on a total of 128 occasions for each arm of the study. The relative deviations of Sodium, Chloride and Bicarbonate concentration were within ±5% of their nominal values for both. The 95% Confidence Intervals for the ratio of the mean solute concentrations on the CCS to PPC lie within the tolerance limit of ±5%. CONCLUSION: Modern CCS is bacteriologically safe and its performance statistically equivalent to PPC. BioMed Central 2017-04-03 /pmc/articles/PMC5379768/ /pubmed/28372556 http://dx.doi.org/10.1186/s12882-017-0537-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Fauziah, K. Go, K. W. Ghazali, A. Zaki, M. Lim, T. O. A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
title | A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
title_full | A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
title_fullStr | A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
title_full_unstemmed | A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
title_short | A randomized cross-over study comparing the performance of HD integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
title_sort | randomized cross-over study comparing the performance of hd integra™ central concentrate system versus pre-produced concentrate in hemodialysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5379768/ https://www.ncbi.nlm.nih.gov/pubmed/28372556 http://dx.doi.org/10.1186/s12882-017-0537-2 |
work_keys_str_mv | AT fauziahk arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT gokw arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT ghazalia arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT zakim arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT limto arandomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT fauziahk randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT gokw randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT ghazalia randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT zakim randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis AT limto randomizedcrossoverstudycomparingtheperformanceofhdintegracentralconcentratesystemversuspreproducedconcentrateinhemodialysis |