Cargando…

Effect of patient anxiety on image motion artefacts in CBCT

BACKGROUND: Artefacts in images related to patient movement decrease image quality, potentially necessitating re-scanning, which leads to an extra radiation dose for the patient. Thus, avoiding patient motion reduces patient exposure to radiation. The aim of this study was to analyse image motion ar...

Descripción completa

Detalles Bibliográficos
Autor principal: Yıldızer Keriş, Elif
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5381051/
https://www.ncbi.nlm.nih.gov/pubmed/28376773
http://dx.doi.org/10.1186/s12903-017-0367-4
_version_ 1782519860531560448
author Yıldızer Keriş, Elif
author_facet Yıldızer Keriş, Elif
author_sort Yıldızer Keriş, Elif
collection PubMed
description BACKGROUND: Artefacts in images related to patient movement decrease image quality, potentially necessitating re-scanning, which leads to an extra radiation dose for the patient. Thus, avoiding patient motion reduces patient exposure to radiation. The aim of this study was to analyse image motion artefacts (MAs) and how they are affected by patient anxiety during cone beam computed tomography (CBCT) examination. METHODS: A total of 100 patients undergoing CBCT examination were investigated. The State Trait Anxiety Inventory (STAI-S and STAI-T) form was used to measure patient anxiety. Patient’s age, gender, dental anxiety score, diagnostic reason for CBCT examination, field of view (FOV), acquisition time, anatomical area, and presence of motion artefacts on images were recorded. Comparisons of the parameters were evaluated using Pearson’s correlation, the chi-square test, the Mann-Whitney U test, the Kruskal-Wallis test and t-tests. The significance level was set at 0.05. RESULTS: The mean values of the scores for the total population were 37.2 for the STAI-S and 41.6 for the STAI-T. Women exhibited higher anxiety levels than men. The patients’ anxiety scores were significantly correlated with dental fear. The prevalence of patients showing motion artefacts was 6%. The mean age of patients with motion artefacts on their images (56.83) was higher than that of patients without (39.14). There was no relationship between motion artefact presence and patient gender, anxiety score, diagnostic reason for CBCT examination, FOV, acquisition time, or anatomical area. Patients showing motion artefacts on their images had higher STAI scores than those with no motion artefacts (non-significant). CONCLUSIONS: The population in this study experienced anxiety before CBCT scanning. Excessive anxiety did not clearly affect whether image motion artefacts were generated during CBCT examination, although a non-significant increase in STAI scores was noticed in patients with motion artefacts on their images.
format Online
Article
Text
id pubmed-5381051
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53810512017-04-10 Effect of patient anxiety on image motion artefacts in CBCT Yıldızer Keriş, Elif BMC Oral Health Research Article BACKGROUND: Artefacts in images related to patient movement decrease image quality, potentially necessitating re-scanning, which leads to an extra radiation dose for the patient. Thus, avoiding patient motion reduces patient exposure to radiation. The aim of this study was to analyse image motion artefacts (MAs) and how they are affected by patient anxiety during cone beam computed tomography (CBCT) examination. METHODS: A total of 100 patients undergoing CBCT examination were investigated. The State Trait Anxiety Inventory (STAI-S and STAI-T) form was used to measure patient anxiety. Patient’s age, gender, dental anxiety score, diagnostic reason for CBCT examination, field of view (FOV), acquisition time, anatomical area, and presence of motion artefacts on images were recorded. Comparisons of the parameters were evaluated using Pearson’s correlation, the chi-square test, the Mann-Whitney U test, the Kruskal-Wallis test and t-tests. The significance level was set at 0.05. RESULTS: The mean values of the scores for the total population were 37.2 for the STAI-S and 41.6 for the STAI-T. Women exhibited higher anxiety levels than men. The patients’ anxiety scores were significantly correlated with dental fear. The prevalence of patients showing motion artefacts was 6%. The mean age of patients with motion artefacts on their images (56.83) was higher than that of patients without (39.14). There was no relationship between motion artefact presence and patient gender, anxiety score, diagnostic reason for CBCT examination, FOV, acquisition time, or anatomical area. Patients showing motion artefacts on their images had higher STAI scores than those with no motion artefacts (non-significant). CONCLUSIONS: The population in this study experienced anxiety before CBCT scanning. Excessive anxiety did not clearly affect whether image motion artefacts were generated during CBCT examination, although a non-significant increase in STAI scores was noticed in patients with motion artefacts on their images. BioMed Central 2017-04-04 /pmc/articles/PMC5381051/ /pubmed/28376773 http://dx.doi.org/10.1186/s12903-017-0367-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Yıldızer Keriş, Elif
Effect of patient anxiety on image motion artefacts in CBCT
title Effect of patient anxiety on image motion artefacts in CBCT
title_full Effect of patient anxiety on image motion artefacts in CBCT
title_fullStr Effect of patient anxiety on image motion artefacts in CBCT
title_full_unstemmed Effect of patient anxiety on image motion artefacts in CBCT
title_short Effect of patient anxiety on image motion artefacts in CBCT
title_sort effect of patient anxiety on image motion artefacts in cbct
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5381051/
https://www.ncbi.nlm.nih.gov/pubmed/28376773
http://dx.doi.org/10.1186/s12903-017-0367-4
work_keys_str_mv AT yıldızerkeriselif effectofpatientanxietyonimagemotionartefactsincbct