Cargando…
An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity
Ammonia is an important indicator among environmental monitoring parameters. In this work, thin-core fiber Mach-Zehnder interferometer deposited with poly (acrylic acid) (PAA), poly (allyamine hydrochloride) (PAH) and single-walled carbon nanotubes (SWCNTs-COOH) sensing film for the detection of amm...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5381216/ https://www.ncbi.nlm.nih.gov/pubmed/28378783 http://dx.doi.org/10.1038/srep44994 |
_version_ | 1782519894905978880 |
---|---|
author | Huang, Xinyue Li, Xueming Yang, Jianchun Tao, Chuanyi Guo, Xiaogang Bao, Hebin Yin, Yanjun Chen, Huifei Zhu, Yuhua |
author_facet | Huang, Xinyue Li, Xueming Yang, Jianchun Tao, Chuanyi Guo, Xiaogang Bao, Hebin Yin, Yanjun Chen, Huifei Zhu, Yuhua |
author_sort | Huang, Xinyue |
collection | PubMed |
description | Ammonia is an important indicator among environmental monitoring parameters. In this work, thin-core fiber Mach-Zehnder interferometer deposited with poly (acrylic acid) (PAA), poly (allyamine hydrochloride) (PAH) and single-walled carbon nanotubes (SWCNTs-COOH) sensing film for the detection of ammonia gas has been presented. The thin-core fiber modal interferometer was made by fusion splicing a small section of thin-core fiber (TCF) between two standard single mode fibers (SMF). A beam propagation method (BPM) is employed for the design of proposed interferometer and numerical simulation. Based on the simulation results, interferometer with a length of 2 cm of thin-core fiber is fabricated and experimentally studied. (PAH/PAA)(2) + [PAH/(PAA + SWCNTs-COOH)](8) film is deposited on the outer surface of thin-core fiber via layer-by-layer (LbL) self-assembly technique. The gas sensor coated with (PAH/PAA)(2) + [PAH/(PAA + SWCNTs-COOH)](8) film towards NH(3) gas exposure at concentrations range from 1 to 960 ppm are analyzed and the sensing capability is demonstrated by optical spectrum analyzer (OSA). Experimental results show that the characteristic wavelength shift has an approximately linear relationship in the range 1–20 ppm, which is in accordance with the numerical simulation. Thus, this paper reveals the potential application of this sensor in monitoring low concentration NH(3) gas. |
format | Online Article Text |
id | pubmed-5381216 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-53812162017-04-10 An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity Huang, Xinyue Li, Xueming Yang, Jianchun Tao, Chuanyi Guo, Xiaogang Bao, Hebin Yin, Yanjun Chen, Huifei Zhu, Yuhua Sci Rep Article Ammonia is an important indicator among environmental monitoring parameters. In this work, thin-core fiber Mach-Zehnder interferometer deposited with poly (acrylic acid) (PAA), poly (allyamine hydrochloride) (PAH) and single-walled carbon nanotubes (SWCNTs-COOH) sensing film for the detection of ammonia gas has been presented. The thin-core fiber modal interferometer was made by fusion splicing a small section of thin-core fiber (TCF) between two standard single mode fibers (SMF). A beam propagation method (BPM) is employed for the design of proposed interferometer and numerical simulation. Based on the simulation results, interferometer with a length of 2 cm of thin-core fiber is fabricated and experimentally studied. (PAH/PAA)(2) + [PAH/(PAA + SWCNTs-COOH)](8) film is deposited on the outer surface of thin-core fiber via layer-by-layer (LbL) self-assembly technique. The gas sensor coated with (PAH/PAA)(2) + [PAH/(PAA + SWCNTs-COOH)](8) film towards NH(3) gas exposure at concentrations range from 1 to 960 ppm are analyzed and the sensing capability is demonstrated by optical spectrum analyzer (OSA). Experimental results show that the characteristic wavelength shift has an approximately linear relationship in the range 1–20 ppm, which is in accordance with the numerical simulation. Thus, this paper reveals the potential application of this sensor in monitoring low concentration NH(3) gas. Nature Publishing Group 2017-04-05 /pmc/articles/PMC5381216/ /pubmed/28378783 http://dx.doi.org/10.1038/srep44994 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Huang, Xinyue Li, Xueming Yang, Jianchun Tao, Chuanyi Guo, Xiaogang Bao, Hebin Yin, Yanjun Chen, Huifei Zhu, Yuhua An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity |
title | An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity |
title_full | An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity |
title_fullStr | An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity |
title_full_unstemmed | An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity |
title_short | An in-line Mach-Zehnder Interferometer Using Thin-core Fiber for Ammonia Gas Sensing With High Sensitivity |
title_sort | in-line mach-zehnder interferometer using thin-core fiber for ammonia gas sensing with high sensitivity |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5381216/ https://www.ncbi.nlm.nih.gov/pubmed/28378783 http://dx.doi.org/10.1038/srep44994 |
work_keys_str_mv | AT huangxinyue aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT lixueming aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT yangjianchun aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT taochuanyi aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT guoxiaogang aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT baohebin aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT yinyanjun aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT chenhuifei aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT zhuyuhua aninlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT huangxinyue inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT lixueming inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT yangjianchun inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT taochuanyi inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT guoxiaogang inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT baohebin inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT yinyanjun inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT chenhuifei inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity AT zhuyuhua inlinemachzehnderinterferometerusingthincorefiberforammoniagassensingwithhighsensitivity |