Cargando…

Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems

In biopharmaceutical production, the optimization of cell culture media and supplementation is a vital element of process development. Optimization is usually achieved through the screening of multiple media, feed and feeding strategies. However, most screening is performed in shake flasks, which ma...

Descripción completa

Detalles Bibliográficos
Autores principales: Chaturvedi, Kirti, Sun, Susan Y., O’Brien, Thomas, Liu, Yan J., Brooks, James W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5381691/
https://www.ncbi.nlm.nih.gov/pubmed/28435799
http://dx.doi.org/10.1016/j.btre.2014.04.001
_version_ 1782519977174106112
author Chaturvedi, Kirti
Sun, Susan Y.
O’Brien, Thomas
Liu, Yan J.
Brooks, James W.
author_facet Chaturvedi, Kirti
Sun, Susan Y.
O’Brien, Thomas
Liu, Yan J.
Brooks, James W.
author_sort Chaturvedi, Kirti
collection PubMed
description In biopharmaceutical production, the optimization of cell culture media and supplementation is a vital element of process development. Optimization is usually achieved through the screening of multiple media, feed and feeding strategies. However, most screening is performed in shake flasks, which makes the screening process very time consuming and inefficient. The use of small scale culture systems for the screening process can aid in the ability to screen multiple formulations during process development. In order to assess the suitability of 24 deep well (24DW) plates with the Duetz sandwich-covers as a small scale culture system for process development, we have tested growth and production performance of CHO cells in 24DW plates and conventional shake flask cultures. Multiple studies were performed to assess well-to-well and plate-to-plate variability in 24DW plates. Additional studies were performed to determine the applicability of 24DW plates for cell culture medium and supplement screening in batch and fed batch processes. Cultures in 24DW plates exhibited similar kinetics in growth, viability and protein production to those cultured in shake flasks, suggesting that 24DW plates with Duetz sandwich-covers can be effectively used for high throughput cell culture screening.
format Online
Article
Text
id pubmed-5381691
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-53816912017-04-21 Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems Chaturvedi, Kirti Sun, Susan Y. O’Brien, Thomas Liu, Yan J. Brooks, James W. Biotechnol Rep (Amst) Article In biopharmaceutical production, the optimization of cell culture media and supplementation is a vital element of process development. Optimization is usually achieved through the screening of multiple media, feed and feeding strategies. However, most screening is performed in shake flasks, which makes the screening process very time consuming and inefficient. The use of small scale culture systems for the screening process can aid in the ability to screen multiple formulations during process development. In order to assess the suitability of 24 deep well (24DW) plates with the Duetz sandwich-covers as a small scale culture system for process development, we have tested growth and production performance of CHO cells in 24DW plates and conventional shake flask cultures. Multiple studies were performed to assess well-to-well and plate-to-plate variability in 24DW plates. Additional studies were performed to determine the applicability of 24DW plates for cell culture medium and supplement screening in batch and fed batch processes. Cultures in 24DW plates exhibited similar kinetics in growth, viability and protein production to those cultured in shake flasks, suggesting that 24DW plates with Duetz sandwich-covers can be effectively used for high throughput cell culture screening. Elsevier 2014-05-06 /pmc/articles/PMC5381691/ /pubmed/28435799 http://dx.doi.org/10.1016/j.btre.2014.04.001 Text en © 2014 The Authors http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Chaturvedi, Kirti
Sun, Susan Y.
O’Brien, Thomas
Liu, Yan J.
Brooks, James W.
Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems
title Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems
title_full Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems
title_fullStr Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems
title_full_unstemmed Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems
title_short Comparison of the behavior of CHO cells during cultivation in 24-square deep well microplates and conventional shake flask systems
title_sort comparison of the behavior of cho cells during cultivation in 24-square deep well microplates and conventional shake flask systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5381691/
https://www.ncbi.nlm.nih.gov/pubmed/28435799
http://dx.doi.org/10.1016/j.btre.2014.04.001
work_keys_str_mv AT chaturvedikirti comparisonofthebehaviorofchocellsduringcultivationin24squaredeepwellmicroplatesandconventionalshakeflasksystems
AT sunsusany comparisonofthebehaviorofchocellsduringcultivationin24squaredeepwellmicroplatesandconventionalshakeflasksystems
AT obrienthomas comparisonofthebehaviorofchocellsduringcultivationin24squaredeepwellmicroplatesandconventionalshakeflasksystems
AT liuyanj comparisonofthebehaviorofchocellsduringcultivationin24squaredeepwellmicroplatesandconventionalshakeflasksystems
AT brooksjamesw comparisonofthebehaviorofchocellsduringcultivationin24squaredeepwellmicroplatesandconventionalshakeflasksystems