Cargando…

Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo

INTRODUCTION: Canine models of severe haemophilia resemble their human equivalents both regarding clinical bleeding phenotype and response to treatment. Therefore pre-clinical studies in haemophilia dogs have allowed researchers to make valuable translational predictions regarding the potency and ef...

Descripción completa

Detalles Bibliográficos
Autores principales: Madsen, Daniel Elenius, Nichols, Timothy C., Merricks, Elizabeth P., Waters, Emily K., Wiinberg, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383133/
https://www.ncbi.nlm.nih.gov/pubmed/28384182
http://dx.doi.org/10.1371/journal.pone.0175030
_version_ 1782520227858219008
author Madsen, Daniel Elenius
Nichols, Timothy C.
Merricks, Elizabeth P.
Waters, Emily K.
Wiinberg, Bo
author_facet Madsen, Daniel Elenius
Nichols, Timothy C.
Merricks, Elizabeth P.
Waters, Emily K.
Wiinberg, Bo
author_sort Madsen, Daniel Elenius
collection PubMed
description INTRODUCTION: Canine models of severe haemophilia resemble their human equivalents both regarding clinical bleeding phenotype and response to treatment. Therefore pre-clinical studies in haemophilia dogs have allowed researchers to make valuable translational predictions regarding the potency and efficacy of new anti-haemophilia drugs (AHDs) in humans. To refine in vivo experiments and reduce number of animals, such translational studies are ideally preceded by in vitro prediction of compound efficacy using a plasma based global coagulation method. One such widely used method is the thrombin generation test (TGT). Unfortunately, commercially available TGTs are incapable of distinguishing between normal and haemophilia canine plasma, and therefore in vitro prediction using TGT has so far not been possible in canine plasma material. AIM: Establish a modified TGT capable of: 1) distinguishing between normal and haemophilia canine plasma, 2) monitoring correlation between canine plasma levels of coagulation factor VIII (FVIII) and IX (FIX) and thrombin generation, 3) assessing for agreement between compound activity and thrombin generation in ex vivo samples. METHODS: A modified TGT assay was established where coagulation was triggered using a commercially available activated partial thromboplastin time reagent. RESULTS: With the modified TGT a significant difference was observed in thrombin generation between normal and haemophilia canine plasma. A dose dependent thrombin generation was observed when assessing haemophilia A and B plasma spiked with dilution series of FVIII and FIX, respectively. Correlation between FVIII activity and thrombin generation was observed when analyzing samples from haemophilia A dogs dosed with canine FVIII. Limit of detection was 0.1% (v/v) FVIII or FIX. CONCLUSION: A novel modified TGT suitable for monitoring and prediction of replacement therapy efficacy in plasma from haemophilia A and B dogs was established.
format Online
Article
Text
id pubmed-5383133
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-53831332017-05-03 Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo Madsen, Daniel Elenius Nichols, Timothy C. Merricks, Elizabeth P. Waters, Emily K. Wiinberg, Bo PLoS One Research Article INTRODUCTION: Canine models of severe haemophilia resemble their human equivalents both regarding clinical bleeding phenotype and response to treatment. Therefore pre-clinical studies in haemophilia dogs have allowed researchers to make valuable translational predictions regarding the potency and efficacy of new anti-haemophilia drugs (AHDs) in humans. To refine in vivo experiments and reduce number of animals, such translational studies are ideally preceded by in vitro prediction of compound efficacy using a plasma based global coagulation method. One such widely used method is the thrombin generation test (TGT). Unfortunately, commercially available TGTs are incapable of distinguishing between normal and haemophilia canine plasma, and therefore in vitro prediction using TGT has so far not been possible in canine plasma material. AIM: Establish a modified TGT capable of: 1) distinguishing between normal and haemophilia canine plasma, 2) monitoring correlation between canine plasma levels of coagulation factor VIII (FVIII) and IX (FIX) and thrombin generation, 3) assessing for agreement between compound activity and thrombin generation in ex vivo samples. METHODS: A modified TGT assay was established where coagulation was triggered using a commercially available activated partial thromboplastin time reagent. RESULTS: With the modified TGT a significant difference was observed in thrombin generation between normal and haemophilia canine plasma. A dose dependent thrombin generation was observed when assessing haemophilia A and B plasma spiked with dilution series of FVIII and FIX, respectively. Correlation between FVIII activity and thrombin generation was observed when analyzing samples from haemophilia A dogs dosed with canine FVIII. Limit of detection was 0.1% (v/v) FVIII or FIX. CONCLUSION: A novel modified TGT suitable for monitoring and prediction of replacement therapy efficacy in plasma from haemophilia A and B dogs was established. Public Library of Science 2017-04-06 /pmc/articles/PMC5383133/ /pubmed/28384182 http://dx.doi.org/10.1371/journal.pone.0175030 Text en © 2017 Madsen et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Madsen, Daniel Elenius
Nichols, Timothy C.
Merricks, Elizabeth P.
Waters, Emily K.
Wiinberg, Bo
Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo
title Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo
title_full Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo
title_fullStr Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo
title_full_unstemmed Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo
title_short Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo
title_sort global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – demonstrated in vitro and ex vivo
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383133/
https://www.ncbi.nlm.nih.gov/pubmed/28384182
http://dx.doi.org/10.1371/journal.pone.0175030
work_keys_str_mv AT madsendanielelenius globalmeasurementofcoagulationinplasmafromnormalandhaemophiliadogsusinganovelmodifiedthrombingenerationtestdemonstratedinvitroandexvivo
AT nicholstimothyc globalmeasurementofcoagulationinplasmafromnormalandhaemophiliadogsusinganovelmodifiedthrombingenerationtestdemonstratedinvitroandexvivo
AT merrickselizabethp globalmeasurementofcoagulationinplasmafromnormalandhaemophiliadogsusinganovelmodifiedthrombingenerationtestdemonstratedinvitroandexvivo
AT watersemilyk globalmeasurementofcoagulationinplasmafromnormalandhaemophiliadogsusinganovelmodifiedthrombingenerationtestdemonstratedinvitroandexvivo
AT wiinbergbo globalmeasurementofcoagulationinplasmafromnormalandhaemophiliadogsusinganovelmodifiedthrombingenerationtestdemonstratedinvitroandexvivo