Cargando…

Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography

There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feas...

Descripción completa

Detalles Bibliográficos
Autores principales: Tu, Sheng, Hu, Fudong, Cai, Wei, Xiao, Liyan, Zhang, Linlin, Zheng, Hong, Jiang, Qiong, Chen, Lianglong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383680/
https://www.ncbi.nlm.nih.gov/pubmed/28039591
http://dx.doi.org/10.1007/s10554-016-1049-z
_version_ 1782520320997982208
author Tu, Sheng
Hu, Fudong
Cai, Wei
Xiao, Liyan
Zhang, Linlin
Zheng, Hong
Jiang, Qiong
Chen, Lianglong
author_facet Tu, Sheng
Hu, Fudong
Cai, Wei
Xiao, Liyan
Zhang, Linlin
Zheng, Hong
Jiang, Qiong
Chen, Lianglong
author_sort Tu, Sheng
collection PubMed
description There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feasibility of detecting polymeric BRS with 3-dimensional reconstruction of BRS images by contrast-enhanced mCT and to determine the optimal imaging settings. BRSs, made of poly-l-lactic acid (PLLA), were implanted in coronary bifurcation models. Five treatments were conducted to examine an optimal condition for imaging BRSs: Baseline treatment, samples were filled with normal saline and scanned with mCT immediately; Treatment-1, -2, -3 and -4, samples were filled with contrast medium and scanned with mCT immediately and 1, 2 and 3 h thereafter, corresponding to soaking time of contrast medium of 0, 1, 2 and 3 h. Compared to Baseline, mCT scanning completely discriminate the scaffold struts from the vascular lumen immediately after filling the samples with contrast agent but not from the vascular wall until the contrast agent soaking time was more than 2 h (Treatment-3 and -4). By setting 10–15 HU as a cut-point of CT values, the scaffold strut detectable rate at Baseline and Teatment-1, -2, -3 and -4 were 1.23 ± 0.31%, 1.65 ± 0.26%, 58.14 ± 12.84%, 97.97 ± 1.43% and 98.90 ± 0.38%, respectively (Treatment-3 vs. Treatment-2, p < 0.01); meanwhile, the success rate of 3D BRS reconstruction with high quality images at Baseline and Teatment-1, -2, -3 and -4 were 1.23%, 1.65%, 58.14%, 97.97% and 98.90%, respectively (Treatment-3 vs. Treatment-2, p < 0.01). In conclusions, reconstruction of 3D BRS images is technically feasible by contrast-enhanced mCT and soaking time of contrast agent for more than 2 h is necessary for complete separation of scaffold struts from the surrounding structures in the phantom samples. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10554-016-1049-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5383680
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-53836802017-04-20 Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography Tu, Sheng Hu, Fudong Cai, Wei Xiao, Liyan Zhang, Linlin Zheng, Hong Jiang, Qiong Chen, Lianglong Int J Cardiovasc Imaging Article There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feasibility of detecting polymeric BRS with 3-dimensional reconstruction of BRS images by contrast-enhanced mCT and to determine the optimal imaging settings. BRSs, made of poly-l-lactic acid (PLLA), were implanted in coronary bifurcation models. Five treatments were conducted to examine an optimal condition for imaging BRSs: Baseline treatment, samples were filled with normal saline and scanned with mCT immediately; Treatment-1, -2, -3 and -4, samples were filled with contrast medium and scanned with mCT immediately and 1, 2 and 3 h thereafter, corresponding to soaking time of contrast medium of 0, 1, 2 and 3 h. Compared to Baseline, mCT scanning completely discriminate the scaffold struts from the vascular lumen immediately after filling the samples with contrast agent but not from the vascular wall until the contrast agent soaking time was more than 2 h (Treatment-3 and -4). By setting 10–15 HU as a cut-point of CT values, the scaffold strut detectable rate at Baseline and Teatment-1, -2, -3 and -4 were 1.23 ± 0.31%, 1.65 ± 0.26%, 58.14 ± 12.84%, 97.97 ± 1.43% and 98.90 ± 0.38%, respectively (Treatment-3 vs. Treatment-2, p < 0.01); meanwhile, the success rate of 3D BRS reconstruction with high quality images at Baseline and Teatment-1, -2, -3 and -4 were 1.23%, 1.65%, 58.14%, 97.97% and 98.90%, respectively (Treatment-3 vs. Treatment-2, p < 0.01). In conclusions, reconstruction of 3D BRS images is technically feasible by contrast-enhanced mCT and soaking time of contrast agent for more than 2 h is necessary for complete separation of scaffold struts from the surrounding structures in the phantom samples. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10554-016-1049-z) contains supplementary material, which is available to authorized users. Springer Netherlands 2016-12-30 2017 /pmc/articles/PMC5383680/ /pubmed/28039591 http://dx.doi.org/10.1007/s10554-016-1049-z Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Tu, Sheng
Hu, Fudong
Cai, Wei
Xiao, Liyan
Zhang, Linlin
Zheng, Hong
Jiang, Qiong
Chen, Lianglong
Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
title Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
title_full Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
title_fullStr Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
title_full_unstemmed Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
title_short Visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
title_sort visualizing polymeric bioresorbable scaffolds with three-dimensional image reconstruction using contrast-enhanced micro-computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383680/
https://www.ncbi.nlm.nih.gov/pubmed/28039591
http://dx.doi.org/10.1007/s10554-016-1049-z
work_keys_str_mv AT tusheng visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT hufudong visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT caiwei visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT xiaoliyan visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT zhanglinlin visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT zhenghong visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT jiangqiong visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography
AT chenlianglong visualizingpolymericbioresorbablescaffoldswiththreedimensionalimagereconstructionusingcontrastenhancedmicrocomputedtomography