Cargando…
Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study
BACKGROUND: The determination of the adequate depth of superior vena cava cannulae during minimally invasive cardiac surgery is important for warranting venous drainage and preventing complications during cardiopulmonary bypass. We investigated whether preoperative cardiac computed tomography might...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383961/ https://www.ncbi.nlm.nih.gov/pubmed/28388941 http://dx.doi.org/10.1186/s12871-017-0347-x |
_version_ | 1782520378610941952 |
---|---|
author | Chin, Ji-Hyun Lee, Eun-Ho Kim, Jong-Il Choi, In-Cheol |
author_facet | Chin, Ji-Hyun Lee, Eun-Ho Kim, Jong-Il Choi, In-Cheol |
author_sort | Chin, Ji-Hyun |
collection | PubMed |
description | BACKGROUND: The determination of the adequate depth of superior vena cava cannulae during minimally invasive cardiac surgery is important for warranting venous drainage and preventing complications during cardiopulmonary bypass. We investigated whether preoperative cardiac computed tomography might be useful for predicting the optimal depth of superior vena cava cannulae. METHODS: The patients who required superior vena cava cannulation and had cardiac tomographic image among those scheduled to undergo a minimally invasive cardiac surgery were evaluated. The distance between the upper border of the clavicular sternal head and the superior vena cava-right atrium junction was measured on cardiac computed tomography. Equivalence test for the difference between the distance measured on cardiac computed tomography and the distance verified by surgeon’s direct inspection in the surgical field was performed. The range −1 cm to 1 cm was predefined as an equivalence region. In addition, the distances between the upper border of the clavicular sternal head and the carina level on chest radiography were measured to compare the relative position of carina with regard to the superior vena cava-right atrium junction. RESULTS: A total of 46 patients were evaluated. The distance from the upper border of the clavicular sternal head to the superior vena cava-right atrium junction measured on cardiac computed tomography and the distance verified by surgeon’s inspection was equivalent, with the 95% confidence interval for the mean difference within the equivalence region (0.05–0.52, P < 0.0001). The carina level on chest radiography was found at least 2 cm above the superior vena cava-right atrium junction in all patients. CONCLUSIONS: Preoperative cardiac computed tomography might be valuable for predicting the adequate depth of superior vena cava cannulae. Additionally, the carina on chest radiography might indicate a useful landmark for proper position of central venous catheter. TRIAL REGISTRATION: This study has been registered at Clinical Research Information Service on 6 July 2012 (KCT0000477). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12871-017-0347-x) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5383961 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-53839612017-04-10 Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study Chin, Ji-Hyun Lee, Eun-Ho Kim, Jong-Il Choi, In-Cheol BMC Anesthesiol Research Article BACKGROUND: The determination of the adequate depth of superior vena cava cannulae during minimally invasive cardiac surgery is important for warranting venous drainage and preventing complications during cardiopulmonary bypass. We investigated whether preoperative cardiac computed tomography might be useful for predicting the optimal depth of superior vena cava cannulae. METHODS: The patients who required superior vena cava cannulation and had cardiac tomographic image among those scheduled to undergo a minimally invasive cardiac surgery were evaluated. The distance between the upper border of the clavicular sternal head and the superior vena cava-right atrium junction was measured on cardiac computed tomography. Equivalence test for the difference between the distance measured on cardiac computed tomography and the distance verified by surgeon’s direct inspection in the surgical field was performed. The range −1 cm to 1 cm was predefined as an equivalence region. In addition, the distances between the upper border of the clavicular sternal head and the carina level on chest radiography were measured to compare the relative position of carina with regard to the superior vena cava-right atrium junction. RESULTS: A total of 46 patients were evaluated. The distance from the upper border of the clavicular sternal head to the superior vena cava-right atrium junction measured on cardiac computed tomography and the distance verified by surgeon’s inspection was equivalent, with the 95% confidence interval for the mean difference within the equivalence region (0.05–0.52, P < 0.0001). The carina level on chest radiography was found at least 2 cm above the superior vena cava-right atrium junction in all patients. CONCLUSIONS: Preoperative cardiac computed tomography might be valuable for predicting the adequate depth of superior vena cava cannulae. Additionally, the carina on chest radiography might indicate a useful landmark for proper position of central venous catheter. TRIAL REGISTRATION: This study has been registered at Clinical Research Information Service on 6 July 2012 (KCT0000477). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12871-017-0347-x) contains supplementary material, which is available to authorized users. BioMed Central 2017-04-07 /pmc/articles/PMC5383961/ /pubmed/28388941 http://dx.doi.org/10.1186/s12871-017-0347-x Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Chin, Ji-Hyun Lee, Eun-Ho Kim, Jong-Il Choi, In-Cheol Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
title | Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
title_full | Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
title_fullStr | Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
title_full_unstemmed | Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
title_short | Prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
title_sort | prediction of the optimal depth for superior vena cava cannulae with cardiac computed tomography during minimally invasive cardiac surgery: a prospective observational cohort study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383961/ https://www.ncbi.nlm.nih.gov/pubmed/28388941 http://dx.doi.org/10.1186/s12871-017-0347-x |
work_keys_str_mv | AT chinjihyun predictionoftheoptimaldepthforsuperiorvenacavacannulaewithcardiaccomputedtomographyduringminimallyinvasivecardiacsurgeryaprospectiveobservationalcohortstudy AT leeeunho predictionoftheoptimaldepthforsuperiorvenacavacannulaewithcardiaccomputedtomographyduringminimallyinvasivecardiacsurgeryaprospectiveobservationalcohortstudy AT kimjongil predictionoftheoptimaldepthforsuperiorvenacavacannulaewithcardiaccomputedtomographyduringminimallyinvasivecardiacsurgeryaprospectiveobservationalcohortstudy AT choiincheol predictionoftheoptimaldepthforsuperiorvenacavacannulaewithcardiaccomputedtomographyduringminimallyinvasivecardiacsurgeryaprospectiveobservationalcohortstudy |