Cargando…
Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification
BACKGROUND: Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signa...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383963/ https://www.ncbi.nlm.nih.gov/pubmed/28385161 http://dx.doi.org/10.1186/s12968-017-0355-5 |
_version_ | 1782520379066023936 |
---|---|
author | Kellman, Peter Hansen, Michael S. Nielles-Vallespin, Sonia Nickander, Jannike Themudo, Raquel Ugander, Martin Xue, Hui |
author_facet | Kellman, Peter Hansen, Michael S. Nielles-Vallespin, Sonia Nickander, Jannike Themudo, Raquel Ugander, Martin Xue, Hui |
author_sort | Kellman, Peter |
collection | PubMed |
description | BACKGROUND: Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signal and contrast agent concentration. This work characterizes sources of non-linearity and presents a systematic approach to accurate measurements of contrast agent concentration in both blood and myocardium. METHODS: A dual sequence approach with separate pulse sequences for AIF and myocardial tissue allowed separate optimization of parameters for blood and myocardium. A systems approach to the overall design was taken to achieve linearity between signal and contrast agent concentration. Conversion of signal intensity values to contrast agent concentration was achieved through a combination of surface coil sensitivity correction, Bloch simulation based look-up table correction, and in the case of the AIF measurement, correction of T2* losses. Validation of signal correction was performed in phantoms, and values for peak AIF concentration and myocardial flow are provided for 29 normal subjects for rest and adenosine stress. RESULTS: For phantoms, the measured fits were within 5% for both AIF and myocardium. In healthy volunteers the peak [Gd] was 3.5 ± 1.2 for stress and 4.4 ± 1.2 mmol/L for rest. The T2* in the left ventricle blood pool at peak AIF was approximately 10 ms. The peak-to-valley ratio was 5.6 for the raw signal intensities without correction, and was 8.3 for the look-up-table (LUT) corrected AIF which represents approximately 48% correction. Without T2* correction the myocardial blood flow estimates are overestimated by approximately 10%. The signal-to-noise ratio of the myocardial signal at peak enhancement (1.5 T) was 17.7 ± 6.6 at stress and the peak [Gd] was 0.49 ± 0.15 mmol/L. The estimated perfusion flow was 3.9 ± 0.38 and 1.03 ± 0.19 ml/min/g using the BTEX model and 3.4 ± 0.39 and 0.95 ± 0.16 using a Fermi model, for stress and rest, respectively. CONCLUSIONS: A dual sequence for myocardial perfusion cardiovascular magnetic resonance and AIF measurement has been optimized for quantification of myocardial blood flow. A validation in phantoms was performed to confirm that the signal conversion to gadolinium concentration was linear. The proposed sequence was integrated with a fully automatic in-line solution for pixel-wise mapping of myocardial blood flow and evaluated in adenosine stress and rest studies on N = 29 normal healthy subjects. Reliable perfusion mapping was demonstrated and produced estimates with low variability. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-017-0355-5) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5383963 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-53839632017-04-10 Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification Kellman, Peter Hansen, Michael S. Nielles-Vallespin, Sonia Nickander, Jannike Themudo, Raquel Ugander, Martin Xue, Hui J Cardiovasc Magn Reson Research BACKGROUND: Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signal and contrast agent concentration. This work characterizes sources of non-linearity and presents a systematic approach to accurate measurements of contrast agent concentration in both blood and myocardium. METHODS: A dual sequence approach with separate pulse sequences for AIF and myocardial tissue allowed separate optimization of parameters for blood and myocardium. A systems approach to the overall design was taken to achieve linearity between signal and contrast agent concentration. Conversion of signal intensity values to contrast agent concentration was achieved through a combination of surface coil sensitivity correction, Bloch simulation based look-up table correction, and in the case of the AIF measurement, correction of T2* losses. Validation of signal correction was performed in phantoms, and values for peak AIF concentration and myocardial flow are provided for 29 normal subjects for rest and adenosine stress. RESULTS: For phantoms, the measured fits were within 5% for both AIF and myocardium. In healthy volunteers the peak [Gd] was 3.5 ± 1.2 for stress and 4.4 ± 1.2 mmol/L for rest. The T2* in the left ventricle blood pool at peak AIF was approximately 10 ms. The peak-to-valley ratio was 5.6 for the raw signal intensities without correction, and was 8.3 for the look-up-table (LUT) corrected AIF which represents approximately 48% correction. Without T2* correction the myocardial blood flow estimates are overestimated by approximately 10%. The signal-to-noise ratio of the myocardial signal at peak enhancement (1.5 T) was 17.7 ± 6.6 at stress and the peak [Gd] was 0.49 ± 0.15 mmol/L. The estimated perfusion flow was 3.9 ± 0.38 and 1.03 ± 0.19 ml/min/g using the BTEX model and 3.4 ± 0.39 and 0.95 ± 0.16 using a Fermi model, for stress and rest, respectively. CONCLUSIONS: A dual sequence for myocardial perfusion cardiovascular magnetic resonance and AIF measurement has been optimized for quantification of myocardial blood flow. A validation in phantoms was performed to confirm that the signal conversion to gadolinium concentration was linear. The proposed sequence was integrated with a fully automatic in-line solution for pixel-wise mapping of myocardial blood flow and evaluated in adenosine stress and rest studies on N = 29 normal healthy subjects. Reliable perfusion mapping was demonstrated and produced estimates with low variability. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-017-0355-5) contains supplementary material, which is available to authorized users. BioMed Central 2017-04-07 /pmc/articles/PMC5383963/ /pubmed/28385161 http://dx.doi.org/10.1186/s12968-017-0355-5 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Kellman, Peter Hansen, Michael S. Nielles-Vallespin, Sonia Nickander, Jannike Themudo, Raquel Ugander, Martin Xue, Hui Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
title | Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
title_full | Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
title_fullStr | Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
title_full_unstemmed | Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
title_short | Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
title_sort | myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5383963/ https://www.ncbi.nlm.nih.gov/pubmed/28385161 http://dx.doi.org/10.1186/s12968-017-0355-5 |
work_keys_str_mv | AT kellmanpeter myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification AT hansenmichaels myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification AT niellesvallespinsonia myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification AT nickanderjannike myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification AT themudoraquel myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification AT ugandermartin myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification AT xuehui myocardialperfusioncardiovascularmagneticresonanceoptimizeddualsequenceandreconstructionforquantification |