Cargando…

Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study

BACKGROUND: While Candida pneumonia is life-threatening, biomarker measurements to early detect suspected Candida pneumonia are lacking. This study compared the diagnostic values of measuring levels of (1, 3)-β-D-glucan in endotracheal aspirate, bronchoalveolar lavage fluid, and serum to detect susp...

Descripción completa

Detalles Bibliográficos
Autores principales: Su, Kang-Cheng, Chou, Kun-Ta, Hsiao, Yi-Han, Tseng, Ching-Min, Su, Vincent Yi-Fong, Lee, Yu-Chin, Perng, Diahn-Warng, Kou, Yu Ru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5385026/
https://www.ncbi.nlm.nih.gov/pubmed/28390391
http://dx.doi.org/10.1186/s12879-017-2364-2
_version_ 1782520528810016768
author Su, Kang-Cheng
Chou, Kun-Ta
Hsiao, Yi-Han
Tseng, Ching-Min
Su, Vincent Yi-Fong
Lee, Yu-Chin
Perng, Diahn-Warng
Kou, Yu Ru
author_facet Su, Kang-Cheng
Chou, Kun-Ta
Hsiao, Yi-Han
Tseng, Ching-Min
Su, Vincent Yi-Fong
Lee, Yu-Chin
Perng, Diahn-Warng
Kou, Yu Ru
author_sort Su, Kang-Cheng
collection PubMed
description BACKGROUND: While Candida pneumonia is life-threatening, biomarker measurements to early detect suspected Candida pneumonia are lacking. This study compared the diagnostic values of measuring levels of (1, 3)-β-D-glucan in endotracheal aspirate, bronchoalveolar lavage fluid, and serum to detect suspected Candida pneumonia in immunocompromised and critically ill patients. METHODS: This prospective, observational study enrolled immunocompromised, critically ill, and ventilated patients with suspected fungal pneumonia in mixed intensive care units from November 2010 to October 2011. Patients with D-glucan confounding factors or other fungal infection were excluded. Endotracheal aspirate, bronchoalveolar lavage fluid and serum were collected from each patient to perform a fungal smear, culture, and D-glucan assay. RESULTS: After screening 166 patients, 31 patients completed the study and were categorized into non-Candida pneumonia/non-candidemia (n = 18), suspected Candida pneumonia (n = 9), and non-Candida pneumonia/candidemia groups (n = 4). D-glucan levels in endotracheal aspirate or bronchoalveolar lavage were highest in suspected Candida pneumonia, while the serum D-glucan level was highest in non-Candida pneumonia/candidemia. In all patients, the D-glucan value in endotracheal aspirate was positively correlated with that in bronchoalveolar lavage fluid. For the detection of suspected Candida pneumonia, the predictive performance (sensitivity/specificity/D-glucan cutoff [pg/ml]) of D-glucan in endotracheal aspirate and bronchoalveolar lavage fluid was 67%/82%/120 and 89%/86%/130, respectively, accounting for areas under the receiver operating characteristic curve of 0.833 and 0.939 (both P < 0.05), respectively. Measuring serum D-glucan was of no diagnostic value (area under curve =0.510, P = 0.931) for the detection of suspected Candida pneumonia in the absence of concurrent candidemia. CONCLUSIONS: D-glucan levels in both endotracheal aspirate and bronchoalveolar lavage, but not in serum, provide good diagnostic values to detect suspected Candida pneumonia and to serve as potential biomarkers for early detection in this patient population. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12879-017-2364-2) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5385026
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-53850262017-04-12 Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study Su, Kang-Cheng Chou, Kun-Ta Hsiao, Yi-Han Tseng, Ching-Min Su, Vincent Yi-Fong Lee, Yu-Chin Perng, Diahn-Warng Kou, Yu Ru BMC Infect Dis Research Article BACKGROUND: While Candida pneumonia is life-threatening, biomarker measurements to early detect suspected Candida pneumonia are lacking. This study compared the diagnostic values of measuring levels of (1, 3)-β-D-glucan in endotracheal aspirate, bronchoalveolar lavage fluid, and serum to detect suspected Candida pneumonia in immunocompromised and critically ill patients. METHODS: This prospective, observational study enrolled immunocompromised, critically ill, and ventilated patients with suspected fungal pneumonia in mixed intensive care units from November 2010 to October 2011. Patients with D-glucan confounding factors or other fungal infection were excluded. Endotracheal aspirate, bronchoalveolar lavage fluid and serum were collected from each patient to perform a fungal smear, culture, and D-glucan assay. RESULTS: After screening 166 patients, 31 patients completed the study and were categorized into non-Candida pneumonia/non-candidemia (n = 18), suspected Candida pneumonia (n = 9), and non-Candida pneumonia/candidemia groups (n = 4). D-glucan levels in endotracheal aspirate or bronchoalveolar lavage were highest in suspected Candida pneumonia, while the serum D-glucan level was highest in non-Candida pneumonia/candidemia. In all patients, the D-glucan value in endotracheal aspirate was positively correlated with that in bronchoalveolar lavage fluid. For the detection of suspected Candida pneumonia, the predictive performance (sensitivity/specificity/D-glucan cutoff [pg/ml]) of D-glucan in endotracheal aspirate and bronchoalveolar lavage fluid was 67%/82%/120 and 89%/86%/130, respectively, accounting for areas under the receiver operating characteristic curve of 0.833 and 0.939 (both P < 0.05), respectively. Measuring serum D-glucan was of no diagnostic value (area under curve =0.510, P = 0.931) for the detection of suspected Candida pneumonia in the absence of concurrent candidemia. CONCLUSIONS: D-glucan levels in both endotracheal aspirate and bronchoalveolar lavage, but not in serum, provide good diagnostic values to detect suspected Candida pneumonia and to serve as potential biomarkers for early detection in this patient population. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12879-017-2364-2) contains supplementary material, which is available to authorized users. BioMed Central 2017-04-08 /pmc/articles/PMC5385026/ /pubmed/28390391 http://dx.doi.org/10.1186/s12879-017-2364-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Su, Kang-Cheng
Chou, Kun-Ta
Hsiao, Yi-Han
Tseng, Ching-Min
Su, Vincent Yi-Fong
Lee, Yu-Chin
Perng, Diahn-Warng
Kou, Yu Ru
Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
title Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
title_full Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
title_fullStr Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
title_full_unstemmed Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
title_short Measuring (1,3)-β-D-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected Candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
title_sort measuring (1,3)-β-d-glucan in tracheal aspirate, bronchoalveolar lavage fluid, and serum for detection of suspected candida pneumonia in immunocompromised and critically ill patients: a prospective observational study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5385026/
https://www.ncbi.nlm.nih.gov/pubmed/28390391
http://dx.doi.org/10.1186/s12879-017-2364-2
work_keys_str_mv AT sukangcheng measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT choukunta measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT hsiaoyihan measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT tsengchingmin measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT suvincentyifong measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT leeyuchin measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT perngdiahnwarng measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy
AT kouyuru measuring13bdglucanintrachealaspiratebronchoalveolarlavagefluidandserumfordetectionofsuspectedcandidapneumoniainimmunocompromisedandcriticallyillpatientsaprospectiveobservationalstudy