Assessment of Airway Distensibility by the Forced Oscillation Technique: Reproducible and Potentially Simplifiable

A non-invasive index of airway distensibility is required to track airway remodeling over time. The forced oscillation technique (FOT) provides such an index by measuring the change in respiratory system conductance at 5 Hz over the corresponding change in lung volume (ΔGrs(5)/ΔV(L)). To become usef...

Descripción completa

Detalles Bibliográficos
Autores principales: Mailhot-Larouche, Samuel, Lachance, Mélanie, Bullone, Michela, Henry, Cyndi, Dandurand, Ronald J., Boulet, Louis-Philippe, Laviolette, Michel, King, Gregory G., Farah, Claude S., Bossé, Ynuk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5388760/
https://www.ncbi.nlm.nih.gov/pubmed/28446881
http://dx.doi.org/10.3389/fphys.2017.00223
Descripción
Sumario:A non-invasive index of airway distensibility is required to track airway remodeling over time. The forced oscillation technique (FOT) provides such an index by measuring the change in respiratory system conductance at 5 Hz over the corresponding change in lung volume (ΔGrs(5)/ΔV(L)). To become useful clinically, this method has to be reproducible and easy to perform. The series of breathing maneuvers required to measure distensibility would be greatly facilitated if the difficulty of breathing below functional residual capacity (FRC) could be precluded and the number of maneuvers could be reduced. The distensibility at lung volumes below FRC is also reduced by several confounders, suggesting that excluding data points below FRC should provide a better surrogate for airway remodeling. The objectives of this study were to investigate the reproducibility of airway distensibility measured by FOT and to assess whether the method could be simplified to increase feasibility. Distensibility was measured at three separate occasions in 13 healthy volunteers. At each visit, three deflationary maneuvers were performed, each consisting of tidal breathing from total lung capacity (TLC) to residual volume by slowly decreasing the end-expiratory volume on each subsequent breath. Distensibility was calculated by using either all data points from TLC to residual volume (RV) or only data points from TLC to FRC for either all three or only the first two deflationary maneuvers. Intra-class correlation coefficients (ICC) were used to assess reproducibility and Bland-Altman analyses were used to assess the level of agreement between the differently calculated values of distensibility. The results indicate that distensibility calculated using all data points is reproducible (ICC = 0.64). Using data points from TLC to FRC slightly improved reproducibility (ICC = 0.68) and increased distensibility by 19.4%, which was expected as distensibility above FRC should not be affected by confounders. Using only data points within the first two maneuvers did not affect reproducibility when tested between TLC and FRC (ICC = 0.66). We conclude that a valuable measure of airway distensibility could potentially be obtained with only two deflationary maneuvers that do not require breathing below FRC. This simplified method would increase feasibility without compromising reproducibility.