Cargando…

Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection

BACKGROUND: Hemolytic anemia caused by a kinked Dacron graft is a rare complication after repair of acute aortic dissection. We present a case of hemolytic anemia due to kinking of previously implanted Dacron graft for ascending aorta dissection treated by surgery and replaced with new Dacron. CASE...

Descripción completa

Detalles Bibliográficos
Autores principales: Sabzi, Feridoun, Ghasemi, Fahimeh, Asadmobini, Atefeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Research and Publications Office of Jimma University 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5389066/
https://www.ncbi.nlm.nih.gov/pubmed/28446857
_version_ 1782521223235764224
author Sabzi, Feridoun
Ghasemi, Fahimeh
Asadmobini, Atefeh
author_facet Sabzi, Feridoun
Ghasemi, Fahimeh
Asadmobini, Atefeh
author_sort Sabzi, Feridoun
collection PubMed
description BACKGROUND: Hemolytic anemia caused by a kinked Dacron graft is a rare complication after repair of acute aortic dissection. We present a case of hemolytic anemia due to kinking of previously implanted Dacron graft for ascending aorta dissection treated by surgery and replaced with new Dacron. CASE DETAILS: We report a case of postoperative hemolytic anemia with kinking of the graft at the outer graft layer and intra luminal bulging of the inner graft. Postoperative computed tomography showed Dacron graft kinking at the mid part of the graft. Transthoracic echocardiography (TTE) revealed good function of repair aortic valve. Upon the redo midsternotomy, we found moderate kinking of the graft at the outer graft layer and intra luminal bulging of the inner graft. We performed reconstruction of the aortic root with a new Dacron. CONCLUSION: The careful literature review showed that there are some few cases of hemolytic anemia after dissection, but no cases in which hemolytic anemia occurred in a patient with kinked Dacron graft after surgery delete treated by replacement of kinked Dacron graft by new one.
format Online
Article
Text
id pubmed-5389066
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Research and Publications Office of Jimma University
record_format MEDLINE/PubMed
spelling pubmed-53890662017-04-26 Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection Sabzi, Feridoun Ghasemi, Fahimeh Asadmobini, Atefeh Ethiop J Health Sci Case Report BACKGROUND: Hemolytic anemia caused by a kinked Dacron graft is a rare complication after repair of acute aortic dissection. We present a case of hemolytic anemia due to kinking of previously implanted Dacron graft for ascending aorta dissection treated by surgery and replaced with new Dacron. CASE DETAILS: We report a case of postoperative hemolytic anemia with kinking of the graft at the outer graft layer and intra luminal bulging of the inner graft. Postoperative computed tomography showed Dacron graft kinking at the mid part of the graft. Transthoracic echocardiography (TTE) revealed good function of repair aortic valve. Upon the redo midsternotomy, we found moderate kinking of the graft at the outer graft layer and intra luminal bulging of the inner graft. We performed reconstruction of the aortic root with a new Dacron. CONCLUSION: The careful literature review showed that there are some few cases of hemolytic anemia after dissection, but no cases in which hemolytic anemia occurred in a patient with kinked Dacron graft after surgery delete treated by replacement of kinked Dacron graft by new one. Research and Publications Office of Jimma University 2016-09 /pmc/articles/PMC5389066/ /pubmed/28446857 Text en Copyright © Jimma University, Research & Publications Office 2016
spellingShingle Case Report
Sabzi, Feridoun
Ghasemi, Fahimeh
Asadmobini, Atefeh
Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
title Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
title_full Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
title_fullStr Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
title_full_unstemmed Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
title_short Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
title_sort hemolytic anemia caused by kinking of dacron grafts implanted in repair of after aortic dissection
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5389066/
https://www.ncbi.nlm.nih.gov/pubmed/28446857
work_keys_str_mv AT sabziferidoun hemolyticanemiacausedbykinkingofdacrongraftsimplantedinrepairofafteraorticdissection
AT ghasemifahimeh hemolyticanemiacausedbykinkingofdacrongraftsimplantedinrepairofafteraorticdissection
AT asadmobiniatefeh hemolyticanemiacausedbykinkingofdacrongraftsimplantedinrepairofafteraorticdissection