Cargando…
Initial Experience with Aortic Valve Replacement via a Minimally Invasive Approach: A Comparison of Stented, Stentless and Sutureless Valves
BACKGROUND: This study aimed to compare the short-term outcomes of MIS-AVR among 3 different types of biological heart valves. MATERIAL/METHODS: Complete data were obtained from 79 patients who underwent MIS-AVR between January 2010 and June 2015. Patients were divided into 3 groups: 27 patients (gr...
Autores principales: | Konertz, Johanna, Zhigalov, Konstantin, Weymann, Alexander, Dohmen, Pascal M. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5389532/ https://www.ncbi.nlm.nih.gov/pubmed/28377566 http://dx.doi.org/10.12659/MSM.901780 |
Ejemplares similares
-
Are Sutureless Aortic Valves Suitable for Severe High-Risk Patients Suffering from Active Infective Aortic Valve Endocarditis?
por: Weymann, Alexander, et al.
Publicado: (2017) -
Sutureless Aortic Valve Replacement in a Patient with Transfemoral Aortic Valve Replacement and Left Ventricular Hypertrophy
por: Christ, Torsten, et al.
Publicado: (2015) -
Sutureless aortic valve replacement in multivalve procedures
por: Zubarevich, Alina, et al.
Publicado: (2021) -
Valve-in-Valve Replacement Using a Sutureless Aortic Valve
por: Dohmen, Pascal M., et al.
Publicado: (2016) -
Stentless aortic valve replacement in the young patient: long-term results
por: Christ, Torsten, et al.
Publicado: (2013)