New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS

Hydrogen sulfide exists widely in mammalian tissues and plays a vital role in physiological and pathophysiological processes. However, striking differences with orders of magnitude were observed for the detected hydrogen sulfide concentrations in biological matrices among different measurements in l...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Bo, Jin, Sheng, Sun, Jiping, Gu, Zhongkai, Sun, Xiaotian, Zhu, Yichun, Huo, Keke, Cao, Zonglian, Yang, Ping, Xin, Xiaoming, Liu, Xinhua, Pan, Lilong, Qiu, Furong, Jiang, Jian, Jia, Yiqun, Ye, Fuyuan, Xie, Ying, Zhu, Yi Zhun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5390247/
https://www.ncbi.nlm.nih.gov/pubmed/28406238
http://dx.doi.org/10.1038/srep46278
_version_ 1782521420421529600
author Tan, Bo
Jin, Sheng
Sun, Jiping
Gu, Zhongkai
Sun, Xiaotian
Zhu, Yichun
Huo, Keke
Cao, Zonglian
Yang, Ping
Xin, Xiaoming
Liu, Xinhua
Pan, Lilong
Qiu, Furong
Jiang, Jian
Jia, Yiqun
Ye, Fuyuan
Xie, Ying
Zhu, Yi Zhun
author_facet Tan, Bo
Jin, Sheng
Sun, Jiping
Gu, Zhongkai
Sun, Xiaotian
Zhu, Yichun
Huo, Keke
Cao, Zonglian
Yang, Ping
Xin, Xiaoming
Liu, Xinhua
Pan, Lilong
Qiu, Furong
Jiang, Jian
Jia, Yiqun
Ye, Fuyuan
Xie, Ying
Zhu, Yi Zhun
author_sort Tan, Bo
collection PubMed
description Hydrogen sulfide exists widely in mammalian tissues and plays a vital role in physiological and pathophysiological processes. However, striking differences with orders of magnitude were observed for the detected hydrogen sulfide concentrations in biological matrices among different measurements in literature, which lead to the uncertainty for examination the biological relevance of hydrogen sulfide. Here, we developed and validated a liquid chromatography- mass spectrometry (LC-MS/MS) method for the determination of hydrogen sulfide in various biological matrices by determination of a derivative of hydrogen sulfide and monobromobimane named sulfide dibimane (SDB). (36)S-labeled SDB was synthesized and validated for using as an internal standard. This method has been successfully used to measure hydrogen sulfide levels in a broad range of biological matrices, such as blood, plasma, tissues, cells, and enzymes, across different species. Moreover, a novel mode that hydrogen sulfide could loosely and non-covalently bind to human serum protein (HSA) and hemoglobin (HB) was revealed by using the developed method.
format Online
Article
Text
id pubmed-5390247
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-53902472017-04-14 New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS Tan, Bo Jin, Sheng Sun, Jiping Gu, Zhongkai Sun, Xiaotian Zhu, Yichun Huo, Keke Cao, Zonglian Yang, Ping Xin, Xiaoming Liu, Xinhua Pan, Lilong Qiu, Furong Jiang, Jian Jia, Yiqun Ye, Fuyuan Xie, Ying Zhu, Yi Zhun Sci Rep Article Hydrogen sulfide exists widely in mammalian tissues and plays a vital role in physiological and pathophysiological processes. However, striking differences with orders of magnitude were observed for the detected hydrogen sulfide concentrations in biological matrices among different measurements in literature, which lead to the uncertainty for examination the biological relevance of hydrogen sulfide. Here, we developed and validated a liquid chromatography- mass spectrometry (LC-MS/MS) method for the determination of hydrogen sulfide in various biological matrices by determination of a derivative of hydrogen sulfide and monobromobimane named sulfide dibimane (SDB). (36)S-labeled SDB was synthesized and validated for using as an internal standard. This method has been successfully used to measure hydrogen sulfide levels in a broad range of biological matrices, such as blood, plasma, tissues, cells, and enzymes, across different species. Moreover, a novel mode that hydrogen sulfide could loosely and non-covalently bind to human serum protein (HSA) and hemoglobin (HB) was revealed by using the developed method. Nature Publishing Group 2017-04-13 /pmc/articles/PMC5390247/ /pubmed/28406238 http://dx.doi.org/10.1038/srep46278 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Tan, Bo
Jin, Sheng
Sun, Jiping
Gu, Zhongkai
Sun, Xiaotian
Zhu, Yichun
Huo, Keke
Cao, Zonglian
Yang, Ping
Xin, Xiaoming
Liu, Xinhua
Pan, Lilong
Qiu, Furong
Jiang, Jian
Jia, Yiqun
Ye, Fuyuan
Xie, Ying
Zhu, Yi Zhun
New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
title New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
title_full New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
title_fullStr New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
title_full_unstemmed New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
title_short New method for quantification of gasotransmitter hydrogen sulfide in biological matrices by LC-MS/MS
title_sort new method for quantification of gasotransmitter hydrogen sulfide in biological matrices by lc-ms/ms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5390247/
https://www.ncbi.nlm.nih.gov/pubmed/28406238
http://dx.doi.org/10.1038/srep46278
work_keys_str_mv AT tanbo newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT jinsheng newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT sunjiping newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT guzhongkai newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT sunxiaotian newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT zhuyichun newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT huokeke newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT caozonglian newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT yangping newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT xinxiaoming newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT liuxinhua newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT panlilong newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT qiufurong newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT jiangjian newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT jiayiqun newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT yefuyuan newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT xieying newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms
AT zhuyizhun newmethodforquantificationofgasotransmitterhydrogensulfideinbiologicalmatricesbylcmsms