Cargando…
Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS: The institutional ethica...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5390622/ https://www.ncbi.nlm.nih.gov/pubmed/28458605 http://dx.doi.org/10.3348/kjr.2017.18.3.526 |
_version_ | 1782521498462846976 |
---|---|
author | Hu, Yi Pan, Shinong Zhao, Xudong Guo, Wenli He, Ming Guo, Qiyong |
author_facet | Hu, Yi Pan, Shinong Zhao, Xudong Guo, Wenli He, Ming Guo, Qiyong |
author_sort | Hu, Yi |
collection | PubMed |
description | OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS: The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. RESULTS: Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. CONCLUSION: O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants. |
format | Online Article Text |
id | pubmed-5390622 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-53906222017-05-01 Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation Hu, Yi Pan, Shinong Zhao, Xudong Guo, Wenli He, Ming Guo, Qiyong Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS: The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. RESULTS: Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. CONCLUSION: O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants. The Korean Society of Radiology 2017 2017-04-03 /pmc/articles/PMC5390622/ /pubmed/28458605 http://dx.doi.org/10.3348/kjr.2017.18.3.526 Text en Copyright © 2017 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Musculoskeletal Imaging Hu, Yi Pan, Shinong Zhao, Xudong Guo, Wenli He, Ming Guo, Qiyong Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation |
title | Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation |
title_full | Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation |
title_fullStr | Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation |
title_full_unstemmed | Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation |
title_short | Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation |
title_sort | value and clinical application of orthopedic metal artifact reduction algorithm in ct scans after orthopedic metal implantation |
topic | Musculoskeletal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5390622/ https://www.ncbi.nlm.nih.gov/pubmed/28458605 http://dx.doi.org/10.3348/kjr.2017.18.3.526 |
work_keys_str_mv | AT huyi valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation AT panshinong valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation AT zhaoxudong valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation AT guowenli valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation AT heming valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation AT guoqiyong valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation |