Cargando…

Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation

OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS: The institutional ethica...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Yi, Pan, Shinong, Zhao, Xudong, Guo, Wenli, He, Ming, Guo, Qiyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5390622/
https://www.ncbi.nlm.nih.gov/pubmed/28458605
http://dx.doi.org/10.3348/kjr.2017.18.3.526
_version_ 1782521498462846976
author Hu, Yi
Pan, Shinong
Zhao, Xudong
Guo, Wenli
He, Ming
Guo, Qiyong
author_facet Hu, Yi
Pan, Shinong
Zhao, Xudong
Guo, Wenli
He, Ming
Guo, Qiyong
author_sort Hu, Yi
collection PubMed
description OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS: The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. RESULTS: Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. CONCLUSION: O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants.
format Online
Article
Text
id pubmed-5390622
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-53906222017-05-01 Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation Hu, Yi Pan, Shinong Zhao, Xudong Guo, Wenli He, Ming Guo, Qiyong Korean J Radiol Musculoskeletal Imaging OBJECTIVE: To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS: The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were implanted into the femurs of three Japanese white rabbits. Preoperative CT was performed at 120 kVp without O-MAR reconstruction, and postoperative CT was performed at 80–140 kVp with O-MAR. Muscular CT attenuation, artifact index (AI) and signal-to-noise ratio (SNR) were compared between preoperative and postoperative images (unpaired t test), between paired O-MAR and non-O-MAR images (paired Student t test) and among different kVp settings (repeated measures ANOVA). Artifacts' severity, muscular homogeneity, visibility of inter-muscular space and definition of bony structures were subjectively evaluated and compared (Wilcoxon rank-sum test). In the clinical study, 20 patients undertook CT scan at low kVp with O-MAR with informed consent. The diagnostic satisfaction of clinical images was subjectively assessed. RESULTS: Animal experiments showed that the use of O-MAR resulted in accurate CT attenuation, lower AI, better SNR, and higher subjective scores (p < 0.010) at all tube voltages. O-MAR images at 100 kVp had almost the same AI and SNR as non-O-MAR images at 140 kVp. All O-MAR images were scored ≥ 3. In addition, 95% of clinical CT images performed at 100 kVp were considered satisfactory. CONCLUSION: O-MAR can effectively reduce orthopedic metal artifacts at different tube voltages, and facilitates low-tube-voltage CT for patients with orthopedic metal implants. The Korean Society of Radiology 2017 2017-04-03 /pmc/articles/PMC5390622/ /pubmed/28458605 http://dx.doi.org/10.3348/kjr.2017.18.3.526 Text en Copyright © 2017 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Hu, Yi
Pan, Shinong
Zhao, Xudong
Guo, Wenli
He, Ming
Guo, Qiyong
Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
title Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
title_full Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
title_fullStr Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
title_full_unstemmed Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
title_short Value and Clinical Application of Orthopedic Metal Artifact Reduction Algorithm in CT Scans after Orthopedic Metal Implantation
title_sort value and clinical application of orthopedic metal artifact reduction algorithm in ct scans after orthopedic metal implantation
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5390622/
https://www.ncbi.nlm.nih.gov/pubmed/28458605
http://dx.doi.org/10.3348/kjr.2017.18.3.526
work_keys_str_mv AT huyi valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation
AT panshinong valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation
AT zhaoxudong valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation
AT guowenli valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation
AT heming valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation
AT guoqiyong valueandclinicalapplicationoforthopedicmetalartifactreductionalgorithminctscansafterorthopedicmetalimplantation