Cargando…
A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound
BACKGROUND: Transcranial magnetic resonance guided focused ultrasound is an emerging technology under evaluation for treatment of essential tremor, a prevalent movement disorder. A qualitative evaluation is performed by a clinician periodically during the procedure to maximize treatment effects and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5392935/ https://www.ncbi.nlm.nih.gov/pubmed/28412948 http://dx.doi.org/10.1186/s12883-017-0856-8 |
_version_ | 1783229494380724224 |
---|---|
author | Tam, Fred Huang, Yuexi Schwartz, Michael L. Schweizer, Tom A. Hynynen, Kullervo Graham, Simon J. |
author_facet | Tam, Fred Huang, Yuexi Schwartz, Michael L. Schweizer, Tom A. Hynynen, Kullervo Graham, Simon J. |
author_sort | Tam, Fred |
collection | PubMed |
description | BACKGROUND: Transcranial magnetic resonance guided focused ultrasound is an emerging technology under evaluation for treatment of essential tremor, a prevalent movement disorder. A qualitative evaluation is performed by a clinician periodically during the procedure to maximize treatment effects and minimize adverse effects. The present work demonstrates a magnetic resonance-compatible method to enable more precise, quantitative measurement of tremor severity. METHODS: Tremor severity was measured in 12 patients pre-, post-, and intra-operatively, using a magnetic resonance-compatible tablet and a computerized adaptation of drawing tasks from the widely-used Fahn-Tolosa-Marin Tremor Rating Scale. Tremor metrics based on spectral analysis were calculated for each drawing and compared using Wilcoxon signed rank tests. RESULTS: Tremor metrics in the dominant (treated) hand were significantly and consistently lower post-operatively compared to pre-operatively, but there was no significant difference in the non-dominant (untreated) hand, as expected. Intra-operative metrics were intermediate between pre- and post-operative metrics. CONCLUSIONS: Use of the tablet for quantitative tremor measurement was demonstrated pre-, post-, and intra-operatively during treatment of essential tremor, complementing standard qualitative assessment. With additional work, the system has potential to add objectivity to clinical trials and to aid treatment decision-making by providing a metric for optimization during the procedure, which may eventually lead to more optimal treatment. Enhancements and further studies are suggested, and extensions to fMRI studies of essential tremor and Parkinson’s disease are also likely. |
format | Online Article Text |
id | pubmed-5392935 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-53929352017-04-20 A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound Tam, Fred Huang, Yuexi Schwartz, Michael L. Schweizer, Tom A. Hynynen, Kullervo Graham, Simon J. BMC Neurol Technical Advance BACKGROUND: Transcranial magnetic resonance guided focused ultrasound is an emerging technology under evaluation for treatment of essential tremor, a prevalent movement disorder. A qualitative evaluation is performed by a clinician periodically during the procedure to maximize treatment effects and minimize adverse effects. The present work demonstrates a magnetic resonance-compatible method to enable more precise, quantitative measurement of tremor severity. METHODS: Tremor severity was measured in 12 patients pre-, post-, and intra-operatively, using a magnetic resonance-compatible tablet and a computerized adaptation of drawing tasks from the widely-used Fahn-Tolosa-Marin Tremor Rating Scale. Tremor metrics based on spectral analysis were calculated for each drawing and compared using Wilcoxon signed rank tests. RESULTS: Tremor metrics in the dominant (treated) hand were significantly and consistently lower post-operatively compared to pre-operatively, but there was no significant difference in the non-dominant (untreated) hand, as expected. Intra-operative metrics were intermediate between pre- and post-operative metrics. CONCLUSIONS: Use of the tablet for quantitative tremor measurement was demonstrated pre-, post-, and intra-operatively during treatment of essential tremor, complementing standard qualitative assessment. With additional work, the system has potential to add objectivity to clinical trials and to aid treatment decision-making by providing a metric for optimization during the procedure, which may eventually lead to more optimal treatment. Enhancements and further studies are suggested, and extensions to fMRI studies of essential tremor and Parkinson’s disease are also likely. BioMed Central 2017-04-17 /pmc/articles/PMC5392935/ /pubmed/28412948 http://dx.doi.org/10.1186/s12883-017-0856-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Technical Advance Tam, Fred Huang, Yuexi Schwartz, Michael L. Schweizer, Tom A. Hynynen, Kullervo Graham, Simon J. A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
title | A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
title_full | A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
title_fullStr | A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
title_full_unstemmed | A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
title_short | A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
title_sort | computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound |
topic | Technical Advance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5392935/ https://www.ncbi.nlm.nih.gov/pubmed/28412948 http://dx.doi.org/10.1186/s12883-017-0856-8 |
work_keys_str_mv | AT tamfred acomputerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT huangyuexi acomputerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT schwartzmichaell acomputerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT schweizertoma acomputerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT hynynenkullervo acomputerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT grahamsimonj acomputerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT tamfred computerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT huangyuexi computerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT schwartzmichaell computerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT schweizertoma computerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT hynynenkullervo computerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound AT grahamsimonj computerizedtabletsystemforevaluatingtreatmentofessentialtremorbymagneticresonanceguidedfocusedultrasound |