Cargando…
In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5394346/ https://www.ncbi.nlm.nih.gov/pubmed/28473988 http://dx.doi.org/10.1155/2017/7376261 |
_version_ | 1783229717076246528 |
---|---|
author | Dincer Kose, Onur Karataslı, Burcin Demircan, Sabit Kose, Taha Emre Cene, Erhan Aya, Serhan Aydın Erdem, Mehmet Ali Cankaya, Abdulkadir Burak |
author_facet | Dincer Kose, Onur Karataslı, Burcin Demircan, Sabit Kose, Taha Emre Cene, Erhan Aya, Serhan Aydın Erdem, Mehmet Ali Cankaya, Abdulkadir Burak |
author_sort | Dincer Kose, Onur |
collection | PubMed |
description | Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. |
format | Online Article Text |
id | pubmed-5394346 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-53943462017-05-04 In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening Dincer Kose, Onur Karataslı, Burcin Demircan, Sabit Kose, Taha Emre Cene, Erhan Aya, Serhan Aydın Erdem, Mehmet Ali Cankaya, Abdulkadir Burak Biomed Res Int Research Article Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. Hindawi 2017 2017-04-03 /pmc/articles/PMC5394346/ /pubmed/28473988 http://dx.doi.org/10.1155/2017/7376261 Text en Copyright © 2017 Onur Dincer Kose et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Dincer Kose, Onur Karataslı, Burcin Demircan, Sabit Kose, Taha Emre Cene, Erhan Aya, Serhan Aydın Erdem, Mehmet Ali Cankaya, Abdulkadir Burak In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening |
title | In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening |
title_full | In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening |
title_fullStr | In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening |
title_full_unstemmed | In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening |
title_short | In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening |
title_sort | in vitro evaluation of manual torque values applied to implant-abutment complex by different clinicians and abutment screw loosening |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5394346/ https://www.ncbi.nlm.nih.gov/pubmed/28473988 http://dx.doi.org/10.1155/2017/7376261 |
work_keys_str_mv | AT dincerkoseonur invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT karataslıburcin invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT demircansabit invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT kosetahaemre invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT ceneerhan invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT ayaserhanaydın invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT erdemmehmetali invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening AT cankayaabdulkadirburak invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening |