In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening

Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application...

Descripción completa

Detalles Bibliográficos
Autores principales: Dincer Kose, Onur, Karataslı, Burcin, Demircan, Sabit, Kose, Taha Emre, Cene, Erhan, Aya, Serhan Aydın, Erdem, Mehmet Ali, Cankaya, Abdulkadir Burak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5394346/
https://www.ncbi.nlm.nih.gov/pubmed/28473988
http://dx.doi.org/10.1155/2017/7376261
_version_ 1783229717076246528
author Dincer Kose, Onur
Karataslı, Burcin
Demircan, Sabit
Kose, Taha Emre
Cene, Erhan
Aya, Serhan Aydın
Erdem, Mehmet Ali
Cankaya, Abdulkadir Burak
author_facet Dincer Kose, Onur
Karataslı, Burcin
Demircan, Sabit
Kose, Taha Emre
Cene, Erhan
Aya, Serhan Aydın
Erdem, Mehmet Ali
Cankaya, Abdulkadir Burak
author_sort Dincer Kose, Onur
collection PubMed
description Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload.
format Online
Article
Text
id pubmed-5394346
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-53943462017-05-04 In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening Dincer Kose, Onur Karataslı, Burcin Demircan, Sabit Kose, Taha Emre Cene, Erhan Aya, Serhan Aydın Erdem, Mehmet Ali Cankaya, Abdulkadir Burak Biomed Res Int Research Article Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of 3.7 and 4.1 mm diameters and standard or solid abutments were used. Each group contained five implant-abutment combinations. The control and experimental groups comprised 20 and 160 specimens, respectively. Implants in the experimental group were tightened by dentists of different specialties. Torsional and bending moments during tightening were measured using a strain gauge. Control group and implants with preload values close to the ideal preload were subjected to a dynamic loading test at 150 N, 15 Hz, and 85,000 cycles. The implants that deformed in this test were examined using an optical microscope to assess deformities. Manual tightening did not yield the manufacturer-recommended preload values. Dynamic loading testing suggested early screw loosening/fracture in samples with insufficient preload. Hindawi 2017 2017-04-03 /pmc/articles/PMC5394346/ /pubmed/28473988 http://dx.doi.org/10.1155/2017/7376261 Text en Copyright © 2017 Onur Dincer Kose et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Dincer Kose, Onur
Karataslı, Burcin
Demircan, Sabit
Kose, Taha Emre
Cene, Erhan
Aya, Serhan Aydın
Erdem, Mehmet Ali
Cankaya, Abdulkadir Burak
In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
title In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
title_full In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
title_fullStr In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
title_full_unstemmed In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
title_short In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
title_sort in vitro evaluation of manual torque values applied to implant-abutment complex by different clinicians and abutment screw loosening
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5394346/
https://www.ncbi.nlm.nih.gov/pubmed/28473988
http://dx.doi.org/10.1155/2017/7376261
work_keys_str_mv AT dincerkoseonur invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT karataslıburcin invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT demircansabit invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT kosetahaemre invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT ceneerhan invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT ayaserhanaydın invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT erdemmehmetali invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening
AT cankayaabdulkadirburak invitroevaluationofmanualtorquevaluesappliedtoimplantabutmentcomplexbydifferentcliniciansandabutmentscrewloosening