Cargando…

Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems

The diluted aerosols from a cigarette (3R4F) and an e-cigarette (Vype ePen) were compared in two commercially available in vitro exposure systems: the Borgwaldt RM20S and Vitrocell VC10. Dosimetry was assessed by measuring deposited aerosol mass in the exposure chambers via quartz crystal microbalan...

Descripción completa

Detalles Bibliográficos
Autores principales: Adamson, Jason, Thorne, David, Zainuddin, Benjamin, Baxter, Andrew, McAughey, John, Gaça, Marianna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5395506/
http://dx.doi.org/10.1186/s13065-016-0221-9
_version_ 1783229871740157952
author Adamson, Jason
Thorne, David
Zainuddin, Benjamin
Baxter, Andrew
McAughey, John
Gaça, Marianna
author_facet Adamson, Jason
Thorne, David
Zainuddin, Benjamin
Baxter, Andrew
McAughey, John
Gaça, Marianna
author_sort Adamson, Jason
collection PubMed
description The diluted aerosols from a cigarette (3R4F) and an e-cigarette (Vype ePen) were compared in two commercially available in vitro exposure systems: the Borgwaldt RM20S and Vitrocell VC10. Dosimetry was assessed by measuring deposited aerosol mass in the exposure chambers via quartz crystal microbalances, followed by quantification of deposited nicotine on their surface. The two exposure systems were shown to generate the same aerosols (pre-dilution) within analytically quantified nicotine concentration levels (p = 0.105). The dosimetry methods employed enabled assessment of the diluted aerosol at the exposure interface. At a common dilution, the per puff e-cigarette aerosol deposited mass was greater than cigarette smoke. At four dilutions, the RM20S produced deposited mass ranging 0.1–0.5 µg/cm(2)/puff for cigarette and 0.1–0.9 µg/cm(2)/puff for e-cigarette; the VC10 ranged 0.4–2.1 µg/cm(2)/puff for cigarette and 0.3–3.3 µg/cm(2)/puff for e-cigarette. In contrast nicotine delivery was much greater from the cigarette than from the e-cigarette at a common dilution, but consistent with the differing nicotine percentages in the respective aerosols. On the RM20S, nicotine ranged 2.5–16.8 ng/cm(2)/puff for the cigarette and 1.2–5.6 ng/cm(2)/puff for the e-cigarette. On the VC10, nicotine concentration ranged 10.0–93.9 ng/cm(2)/puff for the cigarette and 4.0–12.3 ng/cm(2)/puff for the e-cigarette. The deposited aerosol from a conventional cigarette and an e-cigarette in vitro are compositionally different; this emphasises the importance of understanding and characterising different product aerosols using dosimetry tools. This will enable easier extrapolation and comparison of pre-clinical data and consumer use studies, to help further explore the reduced risk potential of next generation nicotine products. [Figure: see text]
format Online
Article
Text
id pubmed-5395506
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-53955062017-05-02 Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems Adamson, Jason Thorne, David Zainuddin, Benjamin Baxter, Andrew McAughey, John Gaça, Marianna Chem Cent J Research Article The diluted aerosols from a cigarette (3R4F) and an e-cigarette (Vype ePen) were compared in two commercially available in vitro exposure systems: the Borgwaldt RM20S and Vitrocell VC10. Dosimetry was assessed by measuring deposited aerosol mass in the exposure chambers via quartz crystal microbalances, followed by quantification of deposited nicotine on their surface. The two exposure systems were shown to generate the same aerosols (pre-dilution) within analytically quantified nicotine concentration levels (p = 0.105). The dosimetry methods employed enabled assessment of the diluted aerosol at the exposure interface. At a common dilution, the per puff e-cigarette aerosol deposited mass was greater than cigarette smoke. At four dilutions, the RM20S produced deposited mass ranging 0.1–0.5 µg/cm(2)/puff for cigarette and 0.1–0.9 µg/cm(2)/puff for e-cigarette; the VC10 ranged 0.4–2.1 µg/cm(2)/puff for cigarette and 0.3–3.3 µg/cm(2)/puff for e-cigarette. In contrast nicotine delivery was much greater from the cigarette than from the e-cigarette at a common dilution, but consistent with the differing nicotine percentages in the respective aerosols. On the RM20S, nicotine ranged 2.5–16.8 ng/cm(2)/puff for the cigarette and 1.2–5.6 ng/cm(2)/puff for the e-cigarette. On the VC10, nicotine concentration ranged 10.0–93.9 ng/cm(2)/puff for the cigarette and 4.0–12.3 ng/cm(2)/puff for the e-cigarette. The deposited aerosol from a conventional cigarette and an e-cigarette in vitro are compositionally different; this emphasises the importance of understanding and characterising different product aerosols using dosimetry tools. This will enable easier extrapolation and comparison of pre-clinical data and consumer use studies, to help further explore the reduced risk potential of next generation nicotine products. [Figure: see text] Springer International Publishing 2016-12-09 /pmc/articles/PMC5395506/ http://dx.doi.org/10.1186/s13065-016-0221-9 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Adamson, Jason
Thorne, David
Zainuddin, Benjamin
Baxter, Andrew
McAughey, John
Gaça, Marianna
Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
title Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
title_full Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
title_fullStr Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
title_full_unstemmed Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
title_short Application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
title_sort application of dosimetry tools for the assessment of e-cigarette aerosol and cigarette smoke generated on two different in vitro exposure systems
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5395506/
http://dx.doi.org/10.1186/s13065-016-0221-9
work_keys_str_mv AT adamsonjason applicationofdosimetrytoolsfortheassessmentofecigaretteaerosolandcigarettesmokegeneratedontwodifferentinvitroexposuresystems
AT thornedavid applicationofdosimetrytoolsfortheassessmentofecigaretteaerosolandcigarettesmokegeneratedontwodifferentinvitroexposuresystems
AT zainuddinbenjamin applicationofdosimetrytoolsfortheassessmentofecigaretteaerosolandcigarettesmokegeneratedontwodifferentinvitroexposuresystems
AT baxterandrew applicationofdosimetrytoolsfortheassessmentofecigaretteaerosolandcigarettesmokegeneratedontwodifferentinvitroexposuresystems
AT mcaugheyjohn applicationofdosimetrytoolsfortheassessmentofecigaretteaerosolandcigarettesmokegeneratedontwodifferentinvitroexposuresystems
AT gacamarianna applicationofdosimetrytoolsfortheassessmentofecigaretteaerosolandcigarettesmokegeneratedontwodifferentinvitroexposuresystems