Cargando…
Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal
INTRODUCTION: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical conte...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Neuroscience Society
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5396172/ https://www.ncbi.nlm.nih.gov/pubmed/28446949 http://dx.doi.org/10.15412/J.BCN.03080106 |
_version_ | 1783230021904629760 |
---|---|
author | Hashemirad, Fahimeh Zoghi, Maryam Fitzgerald, Paul B Jaberzadeh, Shapour |
author_facet | Hashemirad, Fahimeh Zoghi, Maryam Fitzgerald, Paul B Jaberzadeh, Shapour |
author_sort | Hashemirad, Fahimeh |
collection | PubMed |
description | INTRODUCTION: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal of initial MEPs elicited by using two types of TMS techniques influences the reliability scores and whether this effect is different in blocks with variable number of MEPs. METHODS: Twenty-three healthy participants were recruited in this study. The stimulus intensity was set at 120% of resting motor threshold (RMT) for one group while the stimulus intensity was adjusted to record MEPs up to 1 mV for the other group. Twenty MEPs were recorded at 3 time points on 2 separate days. An intra-class correlation coefficient (ICC) reliability with absolute agreement and analysis of variance model were used to assess reliability of the MEP amplitudes for blocks with variable number of MEPs. RESULTS: A decrease in ICC values was observed with removal of 3 or 5 MEPs in both techniques when compared to all MEP responses in any given block. Therefore, removal of the first 3 or 5 MEPs failed to further increase the reliability of MEP responses. CONCLUSION: Our findings revealed that a greater number of trials involving averaged MEPs can influence TMS reliability more than removal of the first trials. |
format | Online Article Text |
id | pubmed-5396172 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Iranian Neuroscience Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-53961722017-04-26 Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal Hashemirad, Fahimeh Zoghi, Maryam Fitzgerald, Paul B Jaberzadeh, Shapour Basic Clin Neurosci Research Papers INTRODUCTION: Transcranial magnetic stimulation (TMS) is a useful tool for assessment of corticospinal excitability (CSE) changes in both healthy individuals and patients with brain disorders. The usefulness of TMS-elicited motor evoked potentials (MEPs) for the assessment of CSE in a clinical context depends on their intra-and inter-session reliability. This study aimed to evaluate if removal of initial MEPs elicited by using two types of TMS techniques influences the reliability scores and whether this effect is different in blocks with variable number of MEPs. METHODS: Twenty-three healthy participants were recruited in this study. The stimulus intensity was set at 120% of resting motor threshold (RMT) for one group while the stimulus intensity was adjusted to record MEPs up to 1 mV for the other group. Twenty MEPs were recorded at 3 time points on 2 separate days. An intra-class correlation coefficient (ICC) reliability with absolute agreement and analysis of variance model were used to assess reliability of the MEP amplitudes for blocks with variable number of MEPs. RESULTS: A decrease in ICC values was observed with removal of 3 or 5 MEPs in both techniques when compared to all MEP responses in any given block. Therefore, removal of the first 3 or 5 MEPs failed to further increase the reliability of MEP responses. CONCLUSION: Our findings revealed that a greater number of trials involving averaged MEPs can influence TMS reliability more than removal of the first trials. Iranian Neuroscience Society 2017-01 /pmc/articles/PMC5396172/ /pubmed/28446949 http://dx.doi.org/10.15412/J.BCN.03080106 Text en Copyright© 2017 Iranian Neuroscience Society http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Papers Hashemirad, Fahimeh Zoghi, Maryam Fitzgerald, Paul B Jaberzadeh, Shapour Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal |
title | Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal |
title_full | Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal |
title_fullStr | Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal |
title_full_unstemmed | Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal |
title_short | Reliability of Motor Evoked Potentials Induced by Transcranial Magnetic Stimulation: The Effects of Initial Motor Evoked Potentials Removal |
title_sort | reliability of motor evoked potentials induced by transcranial magnetic stimulation: the effects of initial motor evoked potentials removal |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5396172/ https://www.ncbi.nlm.nih.gov/pubmed/28446949 http://dx.doi.org/10.15412/J.BCN.03080106 |
work_keys_str_mv | AT hashemiradfahimeh reliabilityofmotorevokedpotentialsinducedbytranscranialmagneticstimulationtheeffectsofinitialmotorevokedpotentialsremoval AT zoghimaryam reliabilityofmotorevokedpotentialsinducedbytranscranialmagneticstimulationtheeffectsofinitialmotorevokedpotentialsremoval AT fitzgeraldpaulb reliabilityofmotorevokedpotentialsinducedbytranscranialmagneticstimulationtheeffectsofinitialmotorevokedpotentialsremoval AT jaberzadehshapour reliabilityofmotorevokedpotentialsinducedbytranscranialmagneticstimulationtheeffectsofinitialmotorevokedpotentialsremoval |