Cargando…

Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements

BACKGROUND: Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardia...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Irene W. Y., Caplin, Joshua D., Azad, Aftab, Wilson, Christina, Fifer, Michael A., Bagchi, Aranya, Liteplo, Andrew S., Noble, Vicki E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5398973/
https://www.ncbi.nlm.nih.gov/pubmed/28429291
http://dx.doi.org/10.1186/s13089-017-0065-0
_version_ 1783230546597380096
author Ma, Irene W. Y.
Caplin, Joshua D.
Azad, Aftab
Wilson, Christina
Fifer, Michael A.
Bagchi, Aranya
Liteplo, Andrew S.
Noble, Vicki E.
author_facet Ma, Irene W. Y.
Caplin, Joshua D.
Azad, Aftab
Wilson, Christina
Fifer, Michael A.
Bagchi, Aranya
Liteplo, Andrew S.
Noble, Vicki E.
author_sort Ma, Irene W. Y.
collection PubMed
description BACKGROUND: Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)(2)/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. RESULTS: Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI −0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02–0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18–0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16–0.62, p = 0.004, respectively. CONCLUSIONS: Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13089-017-0065-0) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5398973
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-53989732017-05-05 Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements Ma, Irene W. Y. Caplin, Joshua D. Azad, Aftab Wilson, Christina Fifer, Michael A. Bagchi, Aranya Liteplo, Andrew S. Noble, Vicki E. Crit Ultrasound J Original Article BACKGROUND: Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)(2)/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. RESULTS: Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI −0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02–0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18–0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16–0.62, p = 0.004, respectively. CONCLUSIONS: Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13089-017-0065-0) contains supplementary material, which is available to authorized users. Springer Milan 2017-04-20 /pmc/articles/PMC5398973/ /pubmed/28429291 http://dx.doi.org/10.1186/s13089-017-0065-0 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Ma, Irene W. Y.
Caplin, Joshua D.
Azad, Aftab
Wilson, Christina
Fifer, Michael A.
Bagchi, Aranya
Liteplo, Andrew S.
Noble, Vicki E.
Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
title Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
title_full Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
title_fullStr Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
title_full_unstemmed Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
title_short Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
title_sort correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5398973/
https://www.ncbi.nlm.nih.gov/pubmed/28429291
http://dx.doi.org/10.1186/s13089-017-0065-0
work_keys_str_mv AT mairenewy correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT caplinjoshuad correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT azadaftab correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT wilsonchristina correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT fifermichaela correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT bagchiaranya correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT liteploandrews correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements
AT noblevickie correlationofcarotidbloodflowandcorrectedcarotidflowtimewithinvasivecardiacoutputmeasurements