Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon

STUDY DESIGN:  Retrospective study. OBJECTIVE:  To assess the learning curve of microendoscopic decompression surgery for lumbar spinal canal stenosis (LSCS). METHODS:  Four hundred eighty LSCS cases involving 753 stenotic lesions limited to the intraspinal canal were treated with microendoscopic de...

Descripción completa

Detalles Bibliográficos
Autores principales: Nomura, Kazunori, Yoshida, Munehito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5400167/
https://www.ncbi.nlm.nih.gov/pubmed/28451510
http://dx.doi.org/10.1055/s-0036-1583943
_version_ 1783230773771370496
author Nomura, Kazunori
Yoshida, Munehito
author_facet Nomura, Kazunori
Yoshida, Munehito
author_sort Nomura, Kazunori
collection PubMed
description STUDY DESIGN:  Retrospective study. OBJECTIVE:  To assess the learning curve of microendoscopic decompression surgery for lumbar spinal canal stenosis (LSCS). METHODS:  Four hundred eighty LSCS cases involving 753 stenotic lesions limited to the intraspinal canal were treated with microendoscopic decompression by a single surgeon at an institution between November 2006 and January 2015. They were numbered chronologically, and the operating time, intraoperative blood loss, and perioperative complications were investigated. Surgical outcomes were evaluated using the Japanese Orthopedic Association (JOA) score for low back pain before and 1 year after the operation. RESULTS:  The mean operating time per level was 66.1 minutes. There was a progressive reduction in the operating time through the case series, and the approximate curve seemed to be y =  − 9.4Ln(x) + 115.0. The blood loss per level, which showed a mean value of 15.0 mL, was more than 50 mL in only 2.7% of the cases after case no. 30 and in 20% of the cases before it. There were 10 (2.1%) cases of perioperative complications, which occurred even after the surgeon had gained mastery of the procedure. The median JOA score improved significantly from 17 points preoperatively to 26 points postoperatively. CONCLUSIONS:  The learning curve of microendoscopic decompression surgery for LSCS has been defined with data for a single surgeon in an institution. The operating time seems to decrease along a natural logarithmic function. The intraoperative blood loss stabilizes after the first 30 cases, whereas perioperative complications can occur at any time even after mastery of the technique.
format Online
Article
Text
id pubmed-5400167
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-54001672017-04-27 Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon Nomura, Kazunori Yoshida, Munehito Global Spine J Original Articles STUDY DESIGN:  Retrospective study. OBJECTIVE:  To assess the learning curve of microendoscopic decompression surgery for lumbar spinal canal stenosis (LSCS). METHODS:  Four hundred eighty LSCS cases involving 753 stenotic lesions limited to the intraspinal canal were treated with microendoscopic decompression by a single surgeon at an institution between November 2006 and January 2015. They were numbered chronologically, and the operating time, intraoperative blood loss, and perioperative complications were investigated. Surgical outcomes were evaluated using the Japanese Orthopedic Association (JOA) score for low back pain before and 1 year after the operation. RESULTS:  The mean operating time per level was 66.1 minutes. There was a progressive reduction in the operating time through the case series, and the approximate curve seemed to be y =  − 9.4Ln(x) + 115.0. The blood loss per level, which showed a mean value of 15.0 mL, was more than 50 mL in only 2.7% of the cases after case no. 30 and in 20% of the cases before it. There were 10 (2.1%) cases of perioperative complications, which occurred even after the surgeon had gained mastery of the procedure. The median JOA score improved significantly from 17 points preoperatively to 26 points postoperatively. CONCLUSIONS:  The learning curve of microendoscopic decompression surgery for LSCS has been defined with data for a single surgeon in an institution. The operating time seems to decrease along a natural logarithmic function. The intraoperative blood loss stabilizes after the first 30 cases, whereas perioperative complications can occur at any time even after mastery of the technique. SAGE Publications 2017-02-01 2017-02 /pmc/articles/PMC5400167/ /pubmed/28451510 http://dx.doi.org/10.1055/s-0036-1583943 Text en © Georg Thieme Verlag KG http://creativecommons.org/licenses/by-nc-nd/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License (http://www.creativecommons.org/licenses/by-nc-nd/3.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Nomura, Kazunori
Yoshida, Munehito
Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon
title Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon
title_full Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon
title_fullStr Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon
title_full_unstemmed Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon
title_short Assessment of the Learning Curve for Microendoscopic Decompression Surgery for Lumbar Spinal Canal Stenosis through an Analysis of 480 Cases Involving a Single Surgeon
title_sort assessment of the learning curve for microendoscopic decompression surgery for lumbar spinal canal stenosis through an analysis of 480 cases involving a single surgeon
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5400167/
https://www.ncbi.nlm.nih.gov/pubmed/28451510
http://dx.doi.org/10.1055/s-0036-1583943
work_keys_str_mv AT nomurakazunori assessmentofthelearningcurveformicroendoscopicdecompressionsurgeryforlumbarspinalcanalstenosisthroughananalysisof480casesinvolvingasinglesurgeon
AT yoshidamunehito assessmentofthelearningcurveformicroendoscopicdecompressionsurgeryforlumbarspinalcanalstenosisthroughananalysisof480casesinvolvingasinglesurgeon