Cargando…

Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery

Volumetric-modulated arc therapy (VMAT) is considered to deliver a better dose distribution and to shorten treatment time. There is a lack of research regarding breast irradiation after breast-conserving surgery (BCS) using VMAT with prone positioning. We developed a new small-arc VMAT methodology a...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Jing, Hu, Tao, Chen, Yeshan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5400323/
https://www.ncbi.nlm.nih.gov/pubmed/27559956
http://dx.doi.org/10.1097/MD.0000000000004609
_version_ 1783230812022374400
author Yu, Jing
Hu, Tao
Chen, Yeshan
author_facet Yu, Jing
Hu, Tao
Chen, Yeshan
author_sort Yu, Jing
collection PubMed
description Volumetric-modulated arc therapy (VMAT) is considered to deliver a better dose distribution and to shorten treatment time. There is a lack of research regarding breast irradiation after breast-conserving surgery (BCS) using VMAT with prone positioning. We developed a new small-arc VMAT methodology and compared it to conventional (fixed-field) intensity-modulated radiation therapy (IMRT) in the dosimetric and treatment relevant parameters for breast cancer patients in the prone position. Ten early-stage breast cancer patients were included in this exploratory study. All patients underwent computed tomography (CT) simulation scan in the prone position and for each patient, IMRT and VMAT plans were generated using the Monaco planning system. Two symmetrical partial arcs were applied in the VMAT plans. The angle ranges of the 2 arcs were set to approximately 60° to 100° and 220° to 260°, with small adjustments to maximize target coverage, while minimizing lung and heart exposure. The IMRT plans used 4 fixed fields. Prescribed doses were 50 Gy in 25 fractions. The target coverage, homogeneity, conformity, dose to organs at risk (OAR), treatment time, and monitor units (MU) were evaluated. Higher median conformal index (CI) and lower homogeneity index (HI) of the planning target volume (PTV) were respectively observed in VMAT and plans group (CI, 95% vs 91%; HI, 0.09 vs 0.12; P < 0.001). The volumes of ipsilateral lung receiving 30, 20, 10, and 5 Gy were lower for VMAT (P < 0.01), being 10%, 14.9%, 25.9%, and 44.9%, respectively, compared to 11.79%, 17.32%, 30.27%, and 50.58% for the IMRT plans. The mean lung dose was also reduced from 10.6 ± 1.8 to 9.6 ± 1.4 Gy (P = 0.001). The volumes of the heart receiving 30 and 40 Gy were similar for the 2 methods. In addition, the median treatment time (161 vs 412 seconds; P < 0.001) and the mean MU (713 vs 878; P < 0.001) were lower for VMAT. Small-arc VMAT plan improved CI and HI for the target, spared the dose of lung, and reduced treatment time and MU, compared to IMRT. It is a more promising irradiation technique for post-BCS radiotherapy.
format Online
Article
Text
id pubmed-5400323
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-54003232017-04-27 Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery Yu, Jing Hu, Tao Chen, Yeshan Medicine (Baltimore) 5700 Volumetric-modulated arc therapy (VMAT) is considered to deliver a better dose distribution and to shorten treatment time. There is a lack of research regarding breast irradiation after breast-conserving surgery (BCS) using VMAT with prone positioning. We developed a new small-arc VMAT methodology and compared it to conventional (fixed-field) intensity-modulated radiation therapy (IMRT) in the dosimetric and treatment relevant parameters for breast cancer patients in the prone position. Ten early-stage breast cancer patients were included in this exploratory study. All patients underwent computed tomography (CT) simulation scan in the prone position and for each patient, IMRT and VMAT plans were generated using the Monaco planning system. Two symmetrical partial arcs were applied in the VMAT plans. The angle ranges of the 2 arcs were set to approximately 60° to 100° and 220° to 260°, with small adjustments to maximize target coverage, while minimizing lung and heart exposure. The IMRT plans used 4 fixed fields. Prescribed doses were 50 Gy in 25 fractions. The target coverage, homogeneity, conformity, dose to organs at risk (OAR), treatment time, and monitor units (MU) were evaluated. Higher median conformal index (CI) and lower homogeneity index (HI) of the planning target volume (PTV) were respectively observed in VMAT and plans group (CI, 95% vs 91%; HI, 0.09 vs 0.12; P < 0.001). The volumes of ipsilateral lung receiving 30, 20, 10, and 5 Gy were lower for VMAT (P < 0.01), being 10%, 14.9%, 25.9%, and 44.9%, respectively, compared to 11.79%, 17.32%, 30.27%, and 50.58% for the IMRT plans. The mean lung dose was also reduced from 10.6 ± 1.8 to 9.6 ± 1.4 Gy (P = 0.001). The volumes of the heart receiving 30 and 40 Gy were similar for the 2 methods. In addition, the median treatment time (161 vs 412 seconds; P < 0.001) and the mean MU (713 vs 878; P < 0.001) were lower for VMAT. Small-arc VMAT plan improved CI and HI for the target, spared the dose of lung, and reduced treatment time and MU, compared to IMRT. It is a more promising irradiation technique for post-BCS radiotherapy. Wolters Kluwer Health 2016-08-26 /pmc/articles/PMC5400323/ /pubmed/27559956 http://dx.doi.org/10.1097/MD.0000000000004609 Text en Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0, where it is permissible to download, share and reproduce the work in any medium, provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 5700
Yu, Jing
Hu, Tao
Chen, Yeshan
Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
title Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
title_full Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
title_fullStr Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
title_full_unstemmed Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
title_short Small-arc volumetric-modulated arc therapy: A new approach that is superior to fixed-field IMRT in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
title_sort small-arc volumetric-modulated arc therapy: a new approach that is superior to fixed-field imrt in optimizing dosimetric and treatment-relevant parameters for patients undergoing whole-breast irradiation following breast-conserving surgery
topic 5700
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5400323/
https://www.ncbi.nlm.nih.gov/pubmed/27559956
http://dx.doi.org/10.1097/MD.0000000000004609
work_keys_str_mv AT yujing smallarcvolumetricmodulatedarctherapyanewapproachthatissuperiortofixedfieldimrtinoptimizingdosimetricandtreatmentrelevantparametersforpatientsundergoingwholebreastirradiationfollowingbreastconservingsurgery
AT hutao smallarcvolumetricmodulatedarctherapyanewapproachthatissuperiortofixedfieldimrtinoptimizingdosimetricandtreatmentrelevantparametersforpatientsundergoingwholebreastirradiationfollowingbreastconservingsurgery
AT chenyeshan smallarcvolumetricmodulatedarctherapyanewapproachthatissuperiortofixedfieldimrtinoptimizingdosimetricandtreatmentrelevantparametersforpatientsundergoingwholebreastirradiationfollowingbreastconservingsurgery