Cargando…

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

BACKGROUND: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the...

Descripción completa

Detalles Bibliográficos
Autores principales: Zargan, S., Ghafarian, P., Shabestani Monfared, A., Sharafi, A.A., Bakhshayeshkaram, M., Ay, M.R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biomedical Physics and Engineering 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5401128/
https://www.ncbi.nlm.nih.gov/pubmed/28451574
_version_ 1783230977834745856
author Zargan, S.
Ghafarian, P.
Shabestani Monfared, A.
Sharafi, A.A.
Bakhshayeshkaram, M.
Ay, M.R.
author_facet Zargan, S.
Ghafarian, P.
Shabestani Monfared, A.
Sharafi, A.A.
Bakhshayeshkaram, M.
Ay, M.R.
author_sort Zargan, S.
collection PubMed
description BACKGROUND: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT and cyclotron center. MATERIALS AND METHODS: 80 patients participated in this study. Thermoluminescence, electronic personal dosimeter and Geiger-Muller dosimeter were also utilized for measurement purpose. RESULTS: The mean annual equivalent organ dose for scanning operator with regard to lens of eyes, thyroid, breast and finger according to mean±SD value, were 0.262±0.044, 0.256±0.046, 0.257±0.040 and 0.316±0.118, respectively. The maximum and minimum estimated annual whole body doses were observed for injector and the chemist group with values of (3.98±0.021) mSv/yr and (1.64±0.014) mSv/yr, respectively. The observed dose rates were 5.67 µSv/h in uptake room at the distance of 0.5 meter from the patient whereas the value 4.94 and 3.08 µSv/h were recorded close to patient’s head in PET/CT room and 3.5 meter from the reception desk. CONCLUSION: In this study, the injector staff and scanning operator received the first high level and second high level of radiation. This study confirmed that low levels of radiation dose were received by all radiation staff during PET/CT procedure using 18F-FDG due to efficient shielding and using trained radiation staff in PET/CT and cyclotron center of Masih Daneshvari hospital.
format Online
Article
Text
id pubmed-5401128
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Journal of Biomedical Physics and Engineering
record_format MEDLINE/PubMed
spelling pubmed-54011282017-04-27 Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry Zargan, S. Ghafarian, P. Shabestani Monfared, A. Sharafi, A.A. Bakhshayeshkaram, M. Ay, M.R. J Biomed Phys Eng Original Article BACKGROUND: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT and cyclotron center. MATERIALS AND METHODS: 80 patients participated in this study. Thermoluminescence, electronic personal dosimeter and Geiger-Muller dosimeter were also utilized for measurement purpose. RESULTS: The mean annual equivalent organ dose for scanning operator with regard to lens of eyes, thyroid, breast and finger according to mean±SD value, were 0.262±0.044, 0.256±0.046, 0.257±0.040 and 0.316±0.118, respectively. The maximum and minimum estimated annual whole body doses were observed for injector and the chemist group with values of (3.98±0.021) mSv/yr and (1.64±0.014) mSv/yr, respectively. The observed dose rates were 5.67 µSv/h in uptake room at the distance of 0.5 meter from the patient whereas the value 4.94 and 3.08 µSv/h were recorded close to patient’s head in PET/CT room and 3.5 meter from the reception desk. CONCLUSION: In this study, the injector staff and scanning operator received the first high level and second high level of radiation. This study confirmed that low levels of radiation dose were received by all radiation staff during PET/CT procedure using 18F-FDG due to efficient shielding and using trained radiation staff in PET/CT and cyclotron center of Masih Daneshvari hospital. Journal of Biomedical Physics and Engineering 2017-03-01 /pmc/articles/PMC5401128/ /pubmed/28451574 Text en Copyright: © Journal of Biomedical Physics and Engineering http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Zargan, S.
Ghafarian, P.
Shabestani Monfared, A.
Sharafi, A.A.
Bakhshayeshkaram, M.
Ay, M.R.
Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
title Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
title_full Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
title_fullStr Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
title_full_unstemmed Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
title_short Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
title_sort evaluation of radiation exposure to staff and environment dose from [18f]-fdg in pet/ct and cyclotron center using thermoluminescent dosimetry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5401128/
https://www.ncbi.nlm.nih.gov/pubmed/28451574
work_keys_str_mv AT zargans evaluationofradiationexposuretostaffandenvironmentdosefrom18ffdginpetctandcyclotroncenterusingthermoluminescentdosimetry
AT ghafarianp evaluationofradiationexposuretostaffandenvironmentdosefrom18ffdginpetctandcyclotroncenterusingthermoluminescentdosimetry
AT shabestanimonfareda evaluationofradiationexposuretostaffandenvironmentdosefrom18ffdginpetctandcyclotroncenterusingthermoluminescentdosimetry
AT sharafiaa evaluationofradiationexposuretostaffandenvironmentdosefrom18ffdginpetctandcyclotroncenterusingthermoluminescentdosimetry
AT bakhshayeshkaramm evaluationofradiationexposuretostaffandenvironmentdosefrom18ffdginpetctandcyclotroncenterusingthermoluminescentdosimetry
AT aymr evaluationofradiationexposuretostaffandenvironmentdosefrom18ffdginpetctandcyclotroncenterusingthermoluminescentdosimetry