Cargando…

Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children

OBJECTIVE: This study objective was to evaluate interobserver agreement between individual pairs of three nuclear medicine physicians in interpretation of renal cortical scintigraphy in children with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). M...

Descripción completa

Detalles Bibliográficos
Autores principales: Beslic, Nermina, Milardovic, Renata, Sadija, Amera, Dzananovic, Lejla, Cavaljuga, Semra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AVICENA, d.o.o., Sarajevo 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5402364/
https://www.ncbi.nlm.nih.gov/pubmed/28484294
http://dx.doi.org/10.5455/aim.2017.25.28-33
_version_ 1783231217499373568
author Beslic, Nermina
Milardovic, Renata
Sadija, Amera
Dzananovic, Lejla
Cavaljuga, Semra
author_facet Beslic, Nermina
Milardovic, Renata
Sadija, Amera
Dzananovic, Lejla
Cavaljuga, Semra
author_sort Beslic, Nermina
collection PubMed
description OBJECTIVE: This study objective was to evaluate interobserver agreement between individual pairs of three nuclear medicine physicians in interpretation of renal cortical scintigraphy in children with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). MATERIALS AND METHODS: Thirty children were imaged in planar and SPECT mode per protocol upon the injection of Tc-99m DMSA dose adjusted to their body weight. Patients were classified according to diagnoses into four groups. Three nuclear medicine physicians interpreted the findings blindly and independently. Renal defects were interpreted as focal and diffuse, per three renal segments. For the raters we calculated simple percentage agreement, the Cohen kappa statistic with 95% confidence intervals, and the overall kappa defining the levels of reliability as almost perfect or perfect, substantial, moderate, fair and slight agreement. RESULTS: Interobserver agreement in planar interpretation was 77,2% (kappa=0.59; 95% confidence interval, 0.41 to 0.75) and SPECT 72,9% (kappa= 0,57; 95% confidence interval, 0,41 to 0,72). In planar interpretation, all individual pairs had moderate agreements except one that had a substantial agreement. In SPECT, all the pairs had moderate agreements except one that had an almost perfect agreement. Overall agreement per kidney site was on planar 73,4% for the left (kappa=0,54, moderate agreement), and 81,1% for the right kidney (kappa 0,63, substantial agreement). On SPECT, there was 72,2% agreement for the left (kappa=0,59, mode rate agreement), and 73,7% for the right kidney (kappa=0,54, moderate agreement). Overall agreement per diagnoses ranged from 70-88,9% on planar (kappa= -0,04 to 0,79), and 50-100% on SPECT (kappa=-0,02-1,000) indicating agreements from slight to substantial. DISCUSSION: Our results suggest acceptable levels of interobserver agreement in all individual pairs of raters with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). For the mode of acquisition, we would recommend hybrid imaging SPECT/CT method to be used whenever possible in the detection of renal cortical defects on Tc-99m-DMSA scintigraphy.
format Online
Article
Text
id pubmed-5402364
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher AVICENA, d.o.o., Sarajevo
record_format MEDLINE/PubMed
spelling pubmed-54023642017-05-08 Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children Beslic, Nermina Milardovic, Renata Sadija, Amera Dzananovic, Lejla Cavaljuga, Semra Acta Inform Med Original Paper OBJECTIVE: This study objective was to evaluate interobserver agreement between individual pairs of three nuclear medicine physicians in interpretation of renal cortical scintigraphy in children with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). MATERIALS AND METHODS: Thirty children were imaged in planar and SPECT mode per protocol upon the injection of Tc-99m DMSA dose adjusted to their body weight. Patients were classified according to diagnoses into four groups. Three nuclear medicine physicians interpreted the findings blindly and independently. Renal defects were interpreted as focal and diffuse, per three renal segments. For the raters we calculated simple percentage agreement, the Cohen kappa statistic with 95% confidence intervals, and the overall kappa defining the levels of reliability as almost perfect or perfect, substantial, moderate, fair and slight agreement. RESULTS: Interobserver agreement in planar interpretation was 77,2% (kappa=0.59; 95% confidence interval, 0.41 to 0.75) and SPECT 72,9% (kappa= 0,57; 95% confidence interval, 0,41 to 0,72). In planar interpretation, all individual pairs had moderate agreements except one that had a substantial agreement. In SPECT, all the pairs had moderate agreements except one that had an almost perfect agreement. Overall agreement per kidney site was on planar 73,4% for the left (kappa=0,54, moderate agreement), and 81,1% for the right kidney (kappa 0,63, substantial agreement). On SPECT, there was 72,2% agreement for the left (kappa=0,59, mode rate agreement), and 73,7% for the right kidney (kappa=0,54, moderate agreement). Overall agreement per diagnoses ranged from 70-88,9% on planar (kappa= -0,04 to 0,79), and 50-100% on SPECT (kappa=-0,02-1,000) indicating agreements from slight to substantial. DISCUSSION: Our results suggest acceptable levels of interobserver agreement in all individual pairs of raters with respect to the mode of acquisition (planar vs. SPECT), diagnoses and kidney site (left vs. right). For the mode of acquisition, we would recommend hybrid imaging SPECT/CT method to be used whenever possible in the detection of renal cortical defects on Tc-99m-DMSA scintigraphy. AVICENA, d.o.o., Sarajevo 2017-03 /pmc/articles/PMC5402364/ /pubmed/28484294 http://dx.doi.org/10.5455/aim.2017.25.28-33 Text en Copyright: © 2017 Nermina Bešlić, Renata Milardović, Amera Šadija, Lejla Džananović, Semra Čavaljuga http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Beslic, Nermina
Milardovic, Renata
Sadija, Amera
Dzananovic, Lejla
Cavaljuga, Semra
Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
title Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
title_full Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
title_fullStr Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
title_full_unstemmed Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
title_short Interobserver Variability in Interpretation of Planar and SPECT Tc-99m-DMSA Renal Scintigraphy in Children
title_sort interobserver variability in interpretation of planar and spect tc-99m-dmsa renal scintigraphy in children
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5402364/
https://www.ncbi.nlm.nih.gov/pubmed/28484294
http://dx.doi.org/10.5455/aim.2017.25.28-33
work_keys_str_mv AT beslicnermina interobservervariabilityininterpretationofplanarandspecttc99mdmsarenalscintigraphyinchildren
AT milardovicrenata interobservervariabilityininterpretationofplanarandspecttc99mdmsarenalscintigraphyinchildren
AT sadijaamera interobservervariabilityininterpretationofplanarandspecttc99mdmsarenalscintigraphyinchildren
AT dzananoviclejla interobservervariabilityininterpretationofplanarandspecttc99mdmsarenalscintigraphyinchildren
AT cavaljugasemra interobservervariabilityininterpretationofplanarandspecttc99mdmsarenalscintigraphyinchildren