Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices

Quality assurance (QA) guidelines are essential to provide uniform execution of clinical trials with uniform quality hyperthermia treatments. This document outlines the requirements for appropriate QA of all current superficial heating equipment including electromagnetic (radiative and capacitive),...

Descripción completa

Detalles Bibliográficos
Autores principales: Dobšíček Trefná, Hana, Crezee, Johannes, Schmidt, Manfred, Marder, Dietmar, Lamprecht, Ulf, Ehmann, Michael, Nadobny, Jacek, Hartmann, Josefin, Lomax, Nicolleta, Abdel-Rahman, Sultan, Curto, Sergio, Bakker, Akke, Hurwitz, Mark D., Diederich, Chris J., Stauffer, Paul R., Van Rhoon, Gerard C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5405104/
https://www.ncbi.nlm.nih.gov/pubmed/28251250
http://dx.doi.org/10.1007/s00066-017-1106-0
_version_ 1783231703821582336
author Dobšíček Trefná, Hana
Crezee, Johannes
Schmidt, Manfred
Marder, Dietmar
Lamprecht, Ulf
Ehmann, Michael
Nadobny, Jacek
Hartmann, Josefin
Lomax, Nicolleta
Abdel-Rahman, Sultan
Curto, Sergio
Bakker, Akke
Hurwitz, Mark D.
Diederich, Chris J.
Stauffer, Paul R.
Van Rhoon, Gerard C.
author_facet Dobšíček Trefná, Hana
Crezee, Johannes
Schmidt, Manfred
Marder, Dietmar
Lamprecht, Ulf
Ehmann, Michael
Nadobny, Jacek
Hartmann, Josefin
Lomax, Nicolleta
Abdel-Rahman, Sultan
Curto, Sergio
Bakker, Akke
Hurwitz, Mark D.
Diederich, Chris J.
Stauffer, Paul R.
Van Rhoon, Gerard C.
author_sort Dobšíček Trefná, Hana
collection PubMed
description Quality assurance (QA) guidelines are essential to provide uniform execution of clinical trials with uniform quality hyperthermia treatments. This document outlines the requirements for appropriate QA of all current superficial heating equipment including electromagnetic (radiative and capacitive), ultrasound, and infrared heating techniques. Detailed instructions are provided how to characterize and document the performance of these hyperthermia applicators in order to apply reproducible hyperthermia treatments of uniform high quality. Earlier documents used specific absorption rate (SAR) to define and characterize applicator performance. In these QA guidelines, temperature rise is the leading parameter for characterization of applicator performance. The intention of this approach is that characterization can be achieved with affordable equipment and easy-to-implement procedures. These characteristics are essential to establish for each individual applicator the specific maximum size and depth of tumors that can be heated adequately. The guidelines in this document are supplemented with a second set of guidelines focusing on the clinical application. Both sets of guidelines were developed by the European Society for Hyperthermic Oncology (ESHO) Technical Committee with participation of senior Society of Thermal Medicine (STM) members and members of the Atzelsberg Circle.
format Online
Article
Text
id pubmed-5405104
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-54051042017-05-09 Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices Dobšíček Trefná, Hana Crezee, Johannes Schmidt, Manfred Marder, Dietmar Lamprecht, Ulf Ehmann, Michael Nadobny, Jacek Hartmann, Josefin Lomax, Nicolleta Abdel-Rahman, Sultan Curto, Sergio Bakker, Akke Hurwitz, Mark D. Diederich, Chris J. Stauffer, Paul R. Van Rhoon, Gerard C. Strahlenther Onkol Review Article Quality assurance (QA) guidelines are essential to provide uniform execution of clinical trials with uniform quality hyperthermia treatments. This document outlines the requirements for appropriate QA of all current superficial heating equipment including electromagnetic (radiative and capacitive), ultrasound, and infrared heating techniques. Detailed instructions are provided how to characterize and document the performance of these hyperthermia applicators in order to apply reproducible hyperthermia treatments of uniform high quality. Earlier documents used specific absorption rate (SAR) to define and characterize applicator performance. In these QA guidelines, temperature rise is the leading parameter for characterization of applicator performance. The intention of this approach is that characterization can be achieved with affordable equipment and easy-to-implement procedures. These characteristics are essential to establish for each individual applicator the specific maximum size and depth of tumors that can be heated adequately. The guidelines in this document are supplemented with a second set of guidelines focusing on the clinical application. Both sets of guidelines were developed by the European Society for Hyperthermic Oncology (ESHO) Technical Committee with participation of senior Society of Thermal Medicine (STM) members and members of the Atzelsberg Circle. Springer Berlin Heidelberg 2017-03-01 2017 /pmc/articles/PMC5405104/ /pubmed/28251250 http://dx.doi.org/10.1007/s00066-017-1106-0 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review Article
Dobšíček Trefná, Hana
Crezee, Johannes
Schmidt, Manfred
Marder, Dietmar
Lamprecht, Ulf
Ehmann, Michael
Nadobny, Jacek
Hartmann, Josefin
Lomax, Nicolleta
Abdel-Rahman, Sultan
Curto, Sergio
Bakker, Akke
Hurwitz, Mark D.
Diederich, Chris J.
Stauffer, Paul R.
Van Rhoon, Gerard C.
Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices
title Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices
title_full Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices
title_fullStr Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices
title_full_unstemmed Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices
title_short Quality assurance guidelines for superficial hyperthermia clinical trials: II. Technical requirements for heating devices
title_sort quality assurance guidelines for superficial hyperthermia clinical trials: ii. technical requirements for heating devices
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5405104/
https://www.ncbi.nlm.nih.gov/pubmed/28251250
http://dx.doi.org/10.1007/s00066-017-1106-0
work_keys_str_mv AT dobsicektrefnahana qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT crezeejohannes qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT schmidtmanfred qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT marderdietmar qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT lamprechtulf qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT ehmannmichael qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT nadobnyjacek qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT hartmannjosefin qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT lomaxnicolleta qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT abdelrahmansultan qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT curtosergio qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT bakkerakke qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT hurwitzmarkd qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT diederichchrisj qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT staufferpaulr qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices
AT vanrhoongerardc qualityassuranceguidelinesforsuperficialhyperthermiaclinicaltrialsiitechnicalrequirementsforheatingdevices