A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica

Objective. To investigate the short- and long-term effects of electroacupuncture (EA) compared with medium-frequency electrotherapy (MFE) on chronic discogenic sciatica. Methods. One hundred participants were randomized into two groups to receive EA (n = 50) or MFE (n = 50) for 4 weeks. A 28-week fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xue, Wang, Yang, Wang, Zhao, Wang, Chao, Ding, Wentao, Liu, Zhishun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5405380/
https://www.ncbi.nlm.nih.gov/pubmed/28491116
http://dx.doi.org/10.1155/2017/9502718
_version_ 1783231754395451392
author Zhang, Xue
Wang, Yang
Wang, Zhao
Wang, Chao
Ding, Wentao
Liu, Zhishun
author_facet Zhang, Xue
Wang, Yang
Wang, Zhao
Wang, Chao
Ding, Wentao
Liu, Zhishun
author_sort Zhang, Xue
collection PubMed
description Objective. To investigate the short- and long-term effects of electroacupuncture (EA) compared with medium-frequency electrotherapy (MFE) on chronic discogenic sciatica. Methods. One hundred participants were randomized into two groups to receive EA (n = 50) or MFE (n = 50) for 4 weeks. A 28-week follow-up of the two groups was performed. The primary outcome measure was the average leg pain intensity. The secondary outcome measures were the low back pain intensity, Oswestry Disability Index (ODI), patient global impression (PGI), drug use frequency, and EA acceptance. Results. The mean changes in the average leg pain numerical rating scale (NRS) scores were 2.30 (1.86–2.57) and 1.06 (0.62–1.51) in the EA and MFE groups at week 4, respectively. The difference was significant (P < 0.001). The long-term follow-up resulted in significant differences. The average leg pain NRS scores decreased by 2.12 (1.70–2.53) and 0.36 (−0.05–0.78) from baseline in the EA and MFE groups, respectively, at week 28. However, low back pain intensity and PGI did not differ significantly at week 4. No serious adverse events occurred. Conclusions. EA showed greater short-term and long-term benefits for chronic discogenic sciatica than MFE, and the effect of EA was superior to that of MFE. The study findings warrant verification. This trial was registered under identifier ChiCTR-IPR-15006370.
format Online
Article
Text
id pubmed-5405380
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54053802017-05-10 A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica Zhang, Xue Wang, Yang Wang, Zhao Wang, Chao Ding, Wentao Liu, Zhishun Evid Based Complement Alternat Med Research Article Objective. To investigate the short- and long-term effects of electroacupuncture (EA) compared with medium-frequency electrotherapy (MFE) on chronic discogenic sciatica. Methods. One hundred participants were randomized into two groups to receive EA (n = 50) or MFE (n = 50) for 4 weeks. A 28-week follow-up of the two groups was performed. The primary outcome measure was the average leg pain intensity. The secondary outcome measures were the low back pain intensity, Oswestry Disability Index (ODI), patient global impression (PGI), drug use frequency, and EA acceptance. Results. The mean changes in the average leg pain numerical rating scale (NRS) scores were 2.30 (1.86–2.57) and 1.06 (0.62–1.51) in the EA and MFE groups at week 4, respectively. The difference was significant (P < 0.001). The long-term follow-up resulted in significant differences. The average leg pain NRS scores decreased by 2.12 (1.70–2.53) and 0.36 (−0.05–0.78) from baseline in the EA and MFE groups, respectively, at week 28. However, low back pain intensity and PGI did not differ significantly at week 4. No serious adverse events occurred. Conclusions. EA showed greater short-term and long-term benefits for chronic discogenic sciatica than MFE, and the effect of EA was superior to that of MFE. The study findings warrant verification. This trial was registered under identifier ChiCTR-IPR-15006370. Hindawi 2017 2017-04-12 /pmc/articles/PMC5405380/ /pubmed/28491116 http://dx.doi.org/10.1155/2017/9502718 Text en Copyright © 2017 Xue Zhang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zhang, Xue
Wang, Yang
Wang, Zhao
Wang, Chao
Ding, Wentao
Liu, Zhishun
A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica
title A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica
title_full A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica
title_fullStr A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica
title_full_unstemmed A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica
title_short A Randomized Clinical Trial Comparing the Effectiveness of Electroacupuncture versus Medium-Frequency Electrotherapy for Discogenic Sciatica
title_sort randomized clinical trial comparing the effectiveness of electroacupuncture versus medium-frequency electrotherapy for discogenic sciatica
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5405380/
https://www.ncbi.nlm.nih.gov/pubmed/28491116
http://dx.doi.org/10.1155/2017/9502718
work_keys_str_mv AT zhangxue arandomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT wangyang arandomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT wangzhao arandomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT wangchao arandomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT dingwentao arandomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT liuzhishun arandomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT zhangxue randomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT wangyang randomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT wangzhao randomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT wangchao randomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT dingwentao randomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica
AT liuzhishun randomizedclinicaltrialcomparingtheeffectivenessofelectroacupunctureversusmediumfrequencyelectrotherapyfordiscogenicsciatica