Cargando…
An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations
In recent years, noninvasive thermal treatment by using high-intensity focused ultrasound (HIFU) has high potential in tumor treatment. The goal of this research is to develop an ultrasound imaging-guided robotic HIFU ablation system for tumor treatment. The system integrates the technologies of ult...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5406740/ https://www.ncbi.nlm.nih.gov/pubmed/28487622 http://dx.doi.org/10.1155/2017/5868695 |
_version_ | 1783232018467782656 |
---|---|
author | An, Chih Yu Syu, Jia Hao Tseng, Ching Shiow Chang, Chih-Ju |
author_facet | An, Chih Yu Syu, Jia Hao Tseng, Ching Shiow Chang, Chih-Ju |
author_sort | An, Chih Yu |
collection | PubMed |
description | In recent years, noninvasive thermal treatment by using high-intensity focused ultrasound (HIFU) has high potential in tumor treatment. The goal of this research is to develop an ultrasound imaging-guided robotic HIFU ablation system for tumor treatment. The system integrates the technologies of ultrasound image-assisted guidance, robotic positioning control, and HIFU treatment planning. With the assistance of ultrasound image guidance technology, the tumor size and location can be determined from ultrasound images as well as the robotic arm can be controlled to position the HIFU transducer to focus on the target tumor. After the development of the system, several experiments were conducted to measure the positioning accuracy of this system. The results show that the average positioning error is 1.01 mm with a standard deviation 0.34, and HIFU ablation accuracy is 1.32 mm with a standard deviation 0.58, which means this system is confirmed with its possibility and accuracy. |
format | Online Article Text |
id | pubmed-5406740 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-54067402017-05-09 An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations An, Chih Yu Syu, Jia Hao Tseng, Ching Shiow Chang, Chih-Ju Appl Bionics Biomech Research Article In recent years, noninvasive thermal treatment by using high-intensity focused ultrasound (HIFU) has high potential in tumor treatment. The goal of this research is to develop an ultrasound imaging-guided robotic HIFU ablation system for tumor treatment. The system integrates the technologies of ultrasound image-assisted guidance, robotic positioning control, and HIFU treatment planning. With the assistance of ultrasound image guidance technology, the tumor size and location can be determined from ultrasound images as well as the robotic arm can be controlled to position the HIFU transducer to focus on the target tumor. After the development of the system, several experiments were conducted to measure the positioning accuracy of this system. The results show that the average positioning error is 1.01 mm with a standard deviation 0.34, and HIFU ablation accuracy is 1.32 mm with a standard deviation 0.58, which means this system is confirmed with its possibility and accuracy. Hindawi 2017 2017-04-13 /pmc/articles/PMC5406740/ /pubmed/28487622 http://dx.doi.org/10.1155/2017/5868695 Text en Copyright © 2017 Chih Yu An et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article An, Chih Yu Syu, Jia Hao Tseng, Ching Shiow Chang, Chih-Ju An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations |
title | An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations |
title_full | An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations |
title_fullStr | An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations |
title_full_unstemmed | An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations |
title_short | An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations |
title_sort | ultrasound imaging-guided robotic hifu ablation experimental system and accuracy evaluations |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5406740/ https://www.ncbi.nlm.nih.gov/pubmed/28487622 http://dx.doi.org/10.1155/2017/5868695 |
work_keys_str_mv | AT anchihyu anultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT syujiahao anultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT tsengchingshiow anultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT changchihju anultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT anchihyu ultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT syujiahao ultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT tsengchingshiow ultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations AT changchihju ultrasoundimagingguidedrobotichifuablationexperimentalsystemandaccuracyevaluations |