Cargando…
Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety
BACKGROUND: In patients with head-neck cancer treated with IMRT, immobility of the upper part of the body during radiation is maintained by means of customised immobilisation devices. The main purpose of this study was to determine how the procedures for preparation of customised immobilisation syst...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5408424/ https://www.ncbi.nlm.nih.gov/pubmed/28449698 http://dx.doi.org/10.1186/s13014-017-0807-y |
_version_ | 1783232304360980480 |
---|---|
author | Contesini, Massimiliano Guberti, Monica Saccani, Roberta Braglia, Luca Iotti, Cinzia Botti, Andrea Abbati, Emilio Iemmi, Marina |
author_facet | Contesini, Massimiliano Guberti, Monica Saccani, Roberta Braglia, Luca Iotti, Cinzia Botti, Andrea Abbati, Emilio Iemmi, Marina |
author_sort | Contesini, Massimiliano |
collection | PubMed |
description | BACKGROUND: In patients with head-neck cancer treated with IMRT, immobility of the upper part of the body during radiation is maintained by means of customised immobilisation devices. The main purpose of this study was to determine how the procedures for preparation of customised immobilisation systems and the patients characteristics influence the extent of setup errors. METHODS: A longitudinal, prospective study involving 29 patients treated with IMRT. Data were collected before CT simulation and during all the treatment sessions (528 setup errors analysed overall); the correlation with possible risk factors for setup errors was explored using a linear mixed model. RESULTS: Setup errors were not influenced by the patient’s anxiety and pain. Temporary removal of the thermoplastic mask before carrying out the CT simulation shows statistically borderline, clinically relevant, increase of setup errors (+24.7%, 95% CI: −0.5% - 55.8%). Moreover, a unit increase of radiation therapists who model the customised thermoplastic mask is associated to a −18% (−29.2% - -4.9%) reduction of the errors. The setup error is influenced by the patient’s physical features; in particular, it increases both in patients in whom the treatment position is obtained with ‘Shoulder down’ (+27.9%, 2.2% - 59.7%) and in patients with ‘Scoliosis/kyphosis’ problems (+65.4%, 2.3% - 164.2%). Using a ‘Small size standard plus customized neck support device’ is associated to a −52.3% (−73.7% - -11.2%) reduction. The increase in number of radiation therapists encountered during the entire treatment cycle does not show associations. Increase in the body mass index is associated with a slight reduction in setup error by (−2.8%, −5% - -0.7%). CONCLUSION: The position of the patient obtained by forcing the shoulders downwards, clinically significant scoliosis or kyphosis and the reduction of the number of radiation therapists who model the thermoplastic mask are found to be statistically significant risk factors that can cause an increase in setup errors, while the use of ‘Small size’ neck support device and patient BMI can diminish them. |
format | Online Article Text |
id | pubmed-5408424 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54084242017-05-02 Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety Contesini, Massimiliano Guberti, Monica Saccani, Roberta Braglia, Luca Iotti, Cinzia Botti, Andrea Abbati, Emilio Iemmi, Marina Radiat Oncol Research BACKGROUND: In patients with head-neck cancer treated with IMRT, immobility of the upper part of the body during radiation is maintained by means of customised immobilisation devices. The main purpose of this study was to determine how the procedures for preparation of customised immobilisation systems and the patients characteristics influence the extent of setup errors. METHODS: A longitudinal, prospective study involving 29 patients treated with IMRT. Data were collected before CT simulation and during all the treatment sessions (528 setup errors analysed overall); the correlation with possible risk factors for setup errors was explored using a linear mixed model. RESULTS: Setup errors were not influenced by the patient’s anxiety and pain. Temporary removal of the thermoplastic mask before carrying out the CT simulation shows statistically borderline, clinically relevant, increase of setup errors (+24.7%, 95% CI: −0.5% - 55.8%). Moreover, a unit increase of radiation therapists who model the customised thermoplastic mask is associated to a −18% (−29.2% - -4.9%) reduction of the errors. The setup error is influenced by the patient’s physical features; in particular, it increases both in patients in whom the treatment position is obtained with ‘Shoulder down’ (+27.9%, 2.2% - 59.7%) and in patients with ‘Scoliosis/kyphosis’ problems (+65.4%, 2.3% - 164.2%). Using a ‘Small size standard plus customized neck support device’ is associated to a −52.3% (−73.7% - -11.2%) reduction. The increase in number of radiation therapists encountered during the entire treatment cycle does not show associations. Increase in the body mass index is associated with a slight reduction in setup error by (−2.8%, −5% - -0.7%). CONCLUSION: The position of the patient obtained by forcing the shoulders downwards, clinically significant scoliosis or kyphosis and the reduction of the number of radiation therapists who model the thermoplastic mask are found to be statistically significant risk factors that can cause an increase in setup errors, while the use of ‘Small size’ neck support device and patient BMI can diminish them. BioMed Central 2017-04-27 /pmc/articles/PMC5408424/ /pubmed/28449698 http://dx.doi.org/10.1186/s13014-017-0807-y Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Contesini, Massimiliano Guberti, Monica Saccani, Roberta Braglia, Luca Iotti, Cinzia Botti, Andrea Abbati, Emilio Iemmi, Marina Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
title | Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
title_full | Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
title_fullStr | Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
title_full_unstemmed | Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
title_short | Setup errors in patients with head-neck cancer (HNC), treated using the Intensity Modulated Radiation Therapy (IMRT) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
title_sort | setup errors in patients with head-neck cancer (hnc), treated using the intensity modulated radiation therapy (imrt) technique: how it influences the customised immobilisation systems, patient’s pain and anxiety |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5408424/ https://www.ncbi.nlm.nih.gov/pubmed/28449698 http://dx.doi.org/10.1186/s13014-017-0807-y |
work_keys_str_mv | AT contesinimassimiliano setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT gubertimonica setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT saccaniroberta setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT braglialuca setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT iotticinzia setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT bottiandrea setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT abbatiemilio setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety AT iemmimarina setuperrorsinpatientswithheadneckcancerhnctreatedusingtheintensitymodulatedradiationtherapyimrttechniquehowitinfluencesthecustomisedimmobilisationsystemspatientspainandanxiety |