Diagnostic Dilemma: Low Oxygen Saturation during Cardiac Surgery
We report a case of rheumatic heart disease with severe mitral stenosis having cyanosis and low oxygen saturation on pulse oximetry. The findings of clinical examination and low values on pulse oximetry were inconsistent with the findings of normal partial pressure of oxygen and oxygen saturation on...