Cargando…
Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and th...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409026/ https://www.ncbi.nlm.nih.gov/pubmed/28445013 http://dx.doi.org/10.3343/alm.2017.37.4.327 |
_version_ | 1783232403838337024 |
---|---|
author | Lee, Se-Na Sohn, Ji Yeon Kong, Jung Hee Eom, Hyeon Seok Lee, Hyewon Kong, Sun-Young |
author_facet | Lee, Se-Na Sohn, Ji Yeon Kong, Jung Hee Eom, Hyeon Seok Lee, Hyewon Kong, Sun-Young |
author_sort | Lee, Se-Na |
collection | PubMed |
description | Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and the parameters of apheresis, products, and collection. The clinical data of 74 patients who underwent autologous PBSC collection from July 2012 to July 2015 were reviewed retrospectively. The patients comprised 48 (65%) men and 26 (35%) women with a median age of 56 yr (range, 23–66 yr). Of 216 procedures, 111 (51%) and 105 (49%) were processed by using COBE and Optia MNC, respectively. PBSC collection rates, throughput, numbers of stem cells retrieved, collection efficacy, and platelet loss were compared. There were no significant differences in the median CD34+ cell counts of collected products (0.61×10(8) vs 0.94×10(8)), CD34 collection efficiency (43.5% vs 42.1%), and loss of platelets (40.1% vs 44.7%). The Spectra Optia MNC apheresis system was comparable to the COBE Spectra system in collecting autologous CD34+ hematopoietic stem cells and retention of platelets. |
format | Online Article Text |
id | pubmed-5409026 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-54090262017-07-01 Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection Lee, Se-Na Sohn, Ji Yeon Kong, Jung Hee Eom, Hyeon Seok Lee, Hyewon Kong, Sun-Young Ann Lab Med Brief Communication Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and the parameters of apheresis, products, and collection. The clinical data of 74 patients who underwent autologous PBSC collection from July 2012 to July 2015 were reviewed retrospectively. The patients comprised 48 (65%) men and 26 (35%) women with a median age of 56 yr (range, 23–66 yr). Of 216 procedures, 111 (51%) and 105 (49%) were processed by using COBE and Optia MNC, respectively. PBSC collection rates, throughput, numbers of stem cells retrieved, collection efficacy, and platelet loss were compared. There were no significant differences in the median CD34+ cell counts of collected products (0.61×10(8) vs 0.94×10(8)), CD34 collection efficiency (43.5% vs 42.1%), and loss of platelets (40.1% vs 44.7%). The Spectra Optia MNC apheresis system was comparable to the COBE Spectra system in collecting autologous CD34+ hematopoietic stem cells and retention of platelets. The Korean Society for Laboratory Medicine 2017-07 2017-04-19 /pmc/articles/PMC5409026/ /pubmed/28445013 http://dx.doi.org/10.3343/alm.2017.37.4.327 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Brief Communication Lee, Se-Na Sohn, Ji Yeon Kong, Jung Hee Eom, Hyeon Seok Lee, Hyewon Kong, Sun-Young Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection |
title | Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection |
title_full | Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection |
title_fullStr | Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection |
title_full_unstemmed | Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection |
title_short | Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection |
title_sort | comparison of two apheresis systems of cobe and optia for autologous peripheral blood stem cell collection |
topic | Brief Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409026/ https://www.ncbi.nlm.nih.gov/pubmed/28445013 http://dx.doi.org/10.3343/alm.2017.37.4.327 |
work_keys_str_mv | AT leesena comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection AT sohnjiyeon comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection AT kongjunghee comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection AT eomhyeonseok comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection AT leehyewon comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection AT kongsunyoung comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection |