Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection

Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and th...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Se-Na, Sohn, Ji Yeon, Kong, Jung Hee, Eom, Hyeon Seok, Lee, Hyewon, Kong, Sun-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409026/
https://www.ncbi.nlm.nih.gov/pubmed/28445013
http://dx.doi.org/10.3343/alm.2017.37.4.327
_version_ 1783232403838337024
author Lee, Se-Na
Sohn, Ji Yeon
Kong, Jung Hee
Eom, Hyeon Seok
Lee, Hyewon
Kong, Sun-Young
author_facet Lee, Se-Na
Sohn, Ji Yeon
Kong, Jung Hee
Eom, Hyeon Seok
Lee, Hyewon
Kong, Sun-Young
author_sort Lee, Se-Na
collection PubMed
description Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and the parameters of apheresis, products, and collection. The clinical data of 74 patients who underwent autologous PBSC collection from July 2012 to July 2015 were reviewed retrospectively. The patients comprised 48 (65%) men and 26 (35%) women with a median age of 56 yr (range, 23–66 yr). Of 216 procedures, 111 (51%) and 105 (49%) were processed by using COBE and Optia MNC, respectively. PBSC collection rates, throughput, numbers of stem cells retrieved, collection efficacy, and platelet loss were compared. There were no significant differences in the median CD34+ cell counts of collected products (0.61×10(8) vs 0.94×10(8)), CD34 collection efficiency (43.5% vs 42.1%), and loss of platelets (40.1% vs 44.7%). The Spectra Optia MNC apheresis system was comparable to the COBE Spectra system in collecting autologous CD34+ hematopoietic stem cells and retention of platelets.
format Online
Article
Text
id pubmed-5409026
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-54090262017-07-01 Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection Lee, Se-Na Sohn, Ji Yeon Kong, Jung Hee Eom, Hyeon Seok Lee, Hyewon Kong, Sun-Young Ann Lab Med Brief Communication Peripheral blood stem cell (PBSC) transplantation following myeloablative therapy is a mainstay of treatment for various types of malignancies. This study aimed to evaluate the differences between the Optia MNC and COBE Spectra MNC systems (Terumo BCT, Japan) according to apheresis procedures and the parameters of apheresis, products, and collection. The clinical data of 74 patients who underwent autologous PBSC collection from July 2012 to July 2015 were reviewed retrospectively. The patients comprised 48 (65%) men and 26 (35%) women with a median age of 56 yr (range, 23–66 yr). Of 216 procedures, 111 (51%) and 105 (49%) were processed by using COBE and Optia MNC, respectively. PBSC collection rates, throughput, numbers of stem cells retrieved, collection efficacy, and platelet loss were compared. There were no significant differences in the median CD34+ cell counts of collected products (0.61×10(8) vs 0.94×10(8)), CD34 collection efficiency (43.5% vs 42.1%), and loss of platelets (40.1% vs 44.7%). The Spectra Optia MNC apheresis system was comparable to the COBE Spectra system in collecting autologous CD34+ hematopoietic stem cells and retention of platelets. The Korean Society for Laboratory Medicine 2017-07 2017-04-19 /pmc/articles/PMC5409026/ /pubmed/28445013 http://dx.doi.org/10.3343/alm.2017.37.4.327 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Brief Communication
Lee, Se-Na
Sohn, Ji Yeon
Kong, Jung Hee
Eom, Hyeon Seok
Lee, Hyewon
Kong, Sun-Young
Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
title Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
title_full Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
title_fullStr Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
title_full_unstemmed Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
title_short Comparison of Two Apheresis Systems of COBE and Optia for Autologous Peripheral Blood Stem Cell Collection
title_sort comparison of two apheresis systems of cobe and optia for autologous peripheral blood stem cell collection
topic Brief Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409026/
https://www.ncbi.nlm.nih.gov/pubmed/28445013
http://dx.doi.org/10.3343/alm.2017.37.4.327
work_keys_str_mv AT leesena comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection
AT sohnjiyeon comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection
AT kongjunghee comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection
AT eomhyeonseok comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection
AT leehyewon comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection
AT kongsunyoung comparisonoftwoapheresissystemsofcobeandoptiaforautologousperipheralbloodstemcellcollection