Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts

Shear waves propagating through interfaces where there is a change in stiffness cause reflected waves that can lead to artifacts in shear wave speed (SWS) reconstructions. Two-dimensional (2-D) directional filters are commonly used to reduce in-plane reflected waves; however, SWS artifacts arise fro...

Descripción completa

Detalles Bibliográficos
Autores principales: Lipman, Samantha L., Rouze, Ned C., Palmeri, Mark L., Nightingale, Kathryn R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409160/
https://www.ncbi.nlm.nih.gov/pubmed/28458448
http://dx.doi.org/10.1109/TUFFC.2016.2558662
_version_ 1783232429898596352
author Lipman, Samantha L.
Rouze, Ned C.
Palmeri, Mark L.
Nightingale, Kathryn R.
author_facet Lipman, Samantha L.
Rouze, Ned C.
Palmeri, Mark L.
Nightingale, Kathryn R.
author_sort Lipman, Samantha L.
collection PubMed
description Shear waves propagating through interfaces where there is a change in stiffness cause reflected waves that can lead to artifacts in shear wave speed (SWS) reconstructions. Two-dimensional (2-D) directional filters are commonly used to reduce in-plane reflected waves; however, SWS artifacts arise from both in- and out-of-imaging-plane reflected waves. Herein, we introduce 3-D shear wave reconstruction methods as an extension of the previous 2-D estimation methods and quantify the reduction in image artifacts through the use of volumetric SWS monitoring and 4-D-directional filters. A Gaussian acoustic radiation force impulse excitation was simulated in phantoms with Young’s modulus (E) of 3 kPa and a 5-mm spherical lesion with E = 6, 12, or 18.75 kPa. The 2-D-, 3-D-, and 4-D-directional filters were applied to the displacement profiles to reduce in-and out-of-plane reflected wave artifacts. Contrast-to-noise ratio and SWS bias within the lesion were calculated for each reconstructed SWS image to evaluate the image quality. For 2-D SWS image reconstructions, the 3-D-directional filters showed greater improvements in image quality than the 2-D filters, and the 4-D-directional filters showed marginal improvement over the 3-D filters. Although 4-D-directional filters can further reduce the impact of large magnitude out-of-plane reflection artifacts in SWS images, computational overhead and transducer costs to acquire 3-D data may outweigh the modest improvements in image quality. The 4-D-directional filters have the largest impact in reducing reflection artifacts in 3-D SWS volumes.
format Online
Article
Text
id pubmed-5409160
institution National Center for Biotechnology Information
language English
publishDate 2016
record_format MEDLINE/PubMed
spelling pubmed-54091602017-04-28 Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts Lipman, Samantha L. Rouze, Ned C. Palmeri, Mark L. Nightingale, Kathryn R. IEEE Trans Ultrason Ferroelectr Freq Control Article Shear waves propagating through interfaces where there is a change in stiffness cause reflected waves that can lead to artifacts in shear wave speed (SWS) reconstructions. Two-dimensional (2-D) directional filters are commonly used to reduce in-plane reflected waves; however, SWS artifacts arise from both in- and out-of-imaging-plane reflected waves. Herein, we introduce 3-D shear wave reconstruction methods as an extension of the previous 2-D estimation methods and quantify the reduction in image artifacts through the use of volumetric SWS monitoring and 4-D-directional filters. A Gaussian acoustic radiation force impulse excitation was simulated in phantoms with Young’s modulus (E) of 3 kPa and a 5-mm spherical lesion with E = 6, 12, or 18.75 kPa. The 2-D-, 3-D-, and 4-D-directional filters were applied to the displacement profiles to reduce in-and out-of-plane reflected wave artifacts. Contrast-to-noise ratio and SWS bias within the lesion were calculated for each reconstructed SWS image to evaluate the image quality. For 2-D SWS image reconstructions, the 3-D-directional filters showed greater improvements in image quality than the 2-D filters, and the 4-D-directional filters showed marginal improvement over the 3-D filters. Although 4-D-directional filters can further reduce the impact of large magnitude out-of-plane reflection artifacts in SWS images, computational overhead and transducer costs to acquire 3-D data may outweigh the modest improvements in image quality. The 4-D-directional filters have the largest impact in reducing reflection artifacts in 3-D SWS volumes. 2016-04-27 2016-08 /pmc/articles/PMC5409160/ /pubmed/28458448 http://dx.doi.org/10.1109/TUFFC.2016.2558662 Text en This work is licensed under a Creative Commons Attribution 3.0 License. For more information, see http://creativecommons.org/licenses/by/3.0/
spellingShingle Article
Lipman, Samantha L.
Rouze, Ned C.
Palmeri, Mark L.
Nightingale, Kathryn R.
Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
title Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
title_full Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
title_fullStr Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
title_full_unstemmed Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
title_short Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
title_sort evaluating the improvement in shear wave speed image quality using multidimensional directional filters in the presence of reflection artifacts
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409160/
https://www.ncbi.nlm.nih.gov/pubmed/28458448
http://dx.doi.org/10.1109/TUFFC.2016.2558662
work_keys_str_mv AT lipmansamanthal evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts
AT rouzenedc evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts
AT palmerimarkl evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts
AT nightingalekathrynr evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts