Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts
Shear waves propagating through interfaces where there is a change in stiffness cause reflected waves that can lead to artifacts in shear wave speed (SWS) reconstructions. Two-dimensional (2-D) directional filters are commonly used to reduce in-plane reflected waves; however, SWS artifacts arise fro...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409160/ https://www.ncbi.nlm.nih.gov/pubmed/28458448 http://dx.doi.org/10.1109/TUFFC.2016.2558662 |
_version_ | 1783232429898596352 |
---|---|
author | Lipman, Samantha L. Rouze, Ned C. Palmeri, Mark L. Nightingale, Kathryn R. |
author_facet | Lipman, Samantha L. Rouze, Ned C. Palmeri, Mark L. Nightingale, Kathryn R. |
author_sort | Lipman, Samantha L. |
collection | PubMed |
description | Shear waves propagating through interfaces where there is a change in stiffness cause reflected waves that can lead to artifacts in shear wave speed (SWS) reconstructions. Two-dimensional (2-D) directional filters are commonly used to reduce in-plane reflected waves; however, SWS artifacts arise from both in- and out-of-imaging-plane reflected waves. Herein, we introduce 3-D shear wave reconstruction methods as an extension of the previous 2-D estimation methods and quantify the reduction in image artifacts through the use of volumetric SWS monitoring and 4-D-directional filters. A Gaussian acoustic radiation force impulse excitation was simulated in phantoms with Young’s modulus (E) of 3 kPa and a 5-mm spherical lesion with E = 6, 12, or 18.75 kPa. The 2-D-, 3-D-, and 4-D-directional filters were applied to the displacement profiles to reduce in-and out-of-plane reflected wave artifacts. Contrast-to-noise ratio and SWS bias within the lesion were calculated for each reconstructed SWS image to evaluate the image quality. For 2-D SWS image reconstructions, the 3-D-directional filters showed greater improvements in image quality than the 2-D filters, and the 4-D-directional filters showed marginal improvement over the 3-D filters. Although 4-D-directional filters can further reduce the impact of large magnitude out-of-plane reflection artifacts in SWS images, computational overhead and transducer costs to acquire 3-D data may outweigh the modest improvements in image quality. The 4-D-directional filters have the largest impact in reducing reflection artifacts in 3-D SWS volumes. |
format | Online Article Text |
id | pubmed-5409160 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
record_format | MEDLINE/PubMed |
spelling | pubmed-54091602017-04-28 Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts Lipman, Samantha L. Rouze, Ned C. Palmeri, Mark L. Nightingale, Kathryn R. IEEE Trans Ultrason Ferroelectr Freq Control Article Shear waves propagating through interfaces where there is a change in stiffness cause reflected waves that can lead to artifacts in shear wave speed (SWS) reconstructions. Two-dimensional (2-D) directional filters are commonly used to reduce in-plane reflected waves; however, SWS artifacts arise from both in- and out-of-imaging-plane reflected waves. Herein, we introduce 3-D shear wave reconstruction methods as an extension of the previous 2-D estimation methods and quantify the reduction in image artifacts through the use of volumetric SWS monitoring and 4-D-directional filters. A Gaussian acoustic radiation force impulse excitation was simulated in phantoms with Young’s modulus (E) of 3 kPa and a 5-mm spherical lesion with E = 6, 12, or 18.75 kPa. The 2-D-, 3-D-, and 4-D-directional filters were applied to the displacement profiles to reduce in-and out-of-plane reflected wave artifacts. Contrast-to-noise ratio and SWS bias within the lesion were calculated for each reconstructed SWS image to evaluate the image quality. For 2-D SWS image reconstructions, the 3-D-directional filters showed greater improvements in image quality than the 2-D filters, and the 4-D-directional filters showed marginal improvement over the 3-D filters. Although 4-D-directional filters can further reduce the impact of large magnitude out-of-plane reflection artifacts in SWS images, computational overhead and transducer costs to acquire 3-D data may outweigh the modest improvements in image quality. The 4-D-directional filters have the largest impact in reducing reflection artifacts in 3-D SWS volumes. 2016-04-27 2016-08 /pmc/articles/PMC5409160/ /pubmed/28458448 http://dx.doi.org/10.1109/TUFFC.2016.2558662 Text en This work is licensed under a Creative Commons Attribution 3.0 License. For more information, see http://creativecommons.org/licenses/by/3.0/ |
spellingShingle | Article Lipman, Samantha L. Rouze, Ned C. Palmeri, Mark L. Nightingale, Kathryn R. Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts |
title | Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts |
title_full | Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts |
title_fullStr | Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts |
title_full_unstemmed | Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts |
title_short | Evaluating the Improvement in Shear Wave Speed Image Quality Using Multidimensional Directional Filters in the Presence of Reflection Artifacts |
title_sort | evaluating the improvement in shear wave speed image quality using multidimensional directional filters in the presence of reflection artifacts |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5409160/ https://www.ncbi.nlm.nih.gov/pubmed/28458448 http://dx.doi.org/10.1109/TUFFC.2016.2558662 |
work_keys_str_mv | AT lipmansamanthal evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts AT rouzenedc evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts AT palmerimarkl evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts AT nightingalekathrynr evaluatingtheimprovementinshearwavespeedimagequalityusingmultidimensionaldirectionalfiltersinthepresenceofreflectionartifacts |