Cargando…

Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report

Peripheral blood stem cell (PBSC) collection from donors through apheresis has become the main source of stem cells for hematopoietic stem cell transplantation. This procedure requires a high blood flow venous access. A peripheral venous catheter (PVC), compared to a central venous catheter (CVC), i...

Descripción completa

Detalles Bibliográficos
Autores principales: Ghazi, Samer, Alaskar, Ahmed, Alzahrani, Mohsen, Damlaj, Moussab, Abuelgasim, Khadega A, Gmati, Giamal, Alshami, Mona, Alshammary, Salman, Al-Surimi, Khaled, Salama, Hind, Alhejazi, Ayman, Jazieh, Abdul-Rahman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: British Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5411715/
https://www.ncbi.nlm.nih.gov/pubmed/28469899
http://dx.doi.org/10.1136/bmjquality.u211975.w4817
_version_ 1783232853120647168
author Ghazi, Samer
Alaskar, Ahmed
Alzahrani, Mohsen
Damlaj, Moussab
Abuelgasim, Khadega A
Gmati, Giamal
Alshami, Mona
Alshammary, Salman
Al-Surimi, Khaled
Salama, Hind
Alhejazi, Ayman
Jazieh, Abdul-Rahman
author_facet Ghazi, Samer
Alaskar, Ahmed
Alzahrani, Mohsen
Damlaj, Moussab
Abuelgasim, Khadega A
Gmati, Giamal
Alshami, Mona
Alshammary, Salman
Al-Surimi, Khaled
Salama, Hind
Alhejazi, Ayman
Jazieh, Abdul-Rahman
author_sort Ghazi, Samer
collection PubMed
description Peripheral blood stem cell (PBSC) collection from donors through apheresis has become the main source of stem cells for hematopoietic stem cell transplantation. This procedure requires a high blood flow venous access. A peripheral venous catheter (PVC), compared to a central venous catheter (CVC), is considered to provide safer venous access. However, initially at our institution, King Abdul-Aziz Medical City - Riyadh, a CVC was frequently used (72%). A quality improvement multidisciplinary team has been formed to conduct a systematic quality performance analysis to evaluate the current process of collecting donor PBSCs with the aim to reduce CVC use to less than the international benchmark (20%). A quality improvement methodology, rapid cycles of plan-do-study-act (PDSA), was used to test a set of initiatives. An Intravenous (IV) team assessed the donor's venous access and inserted an appropriate PVC when feasible. This project ran over 16 months with 42 adult donors undergoing PBSC collection. During the first PDSA cycle, 1 CVC was inserted for every 4 donors. In the second PDSA cycle, 1 CVC was inserted for every 8 apheresis donations. In the third PDSA cycle, no CVC was used for 30 apheresis donations. The targeted stem cell dose was collected successfully in one apheresis session in all donors assigned for PVC access with no complications. A significant reduction of CVC use from 72% to 0% was achieved. This quality improvement project demonstrated that a successful apheresis procedure can be achieved easily and safely in the majority of PBSC donors preventing the potential adverse events associated with CVCs. The interdisciplinary collaboration between the IV team, apheresis and clinical hematology teams was paramount to optimize the safe care of donors.
format Online
Article
Text
id pubmed-5411715
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher British Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-54117152017-05-03 Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report Ghazi, Samer Alaskar, Ahmed Alzahrani, Mohsen Damlaj, Moussab Abuelgasim, Khadega A Gmati, Giamal Alshami, Mona Alshammary, Salman Al-Surimi, Khaled Salama, Hind Alhejazi, Ayman Jazieh, Abdul-Rahman BMJ Qual Improv Rep BMJ Quality Improvement Programme Peripheral blood stem cell (PBSC) collection from donors through apheresis has become the main source of stem cells for hematopoietic stem cell transplantation. This procedure requires a high blood flow venous access. A peripheral venous catheter (PVC), compared to a central venous catheter (CVC), is considered to provide safer venous access. However, initially at our institution, King Abdul-Aziz Medical City - Riyadh, a CVC was frequently used (72%). A quality improvement multidisciplinary team has been formed to conduct a systematic quality performance analysis to evaluate the current process of collecting donor PBSCs with the aim to reduce CVC use to less than the international benchmark (20%). A quality improvement methodology, rapid cycles of plan-do-study-act (PDSA), was used to test a set of initiatives. An Intravenous (IV) team assessed the donor's venous access and inserted an appropriate PVC when feasible. This project ran over 16 months with 42 adult donors undergoing PBSC collection. During the first PDSA cycle, 1 CVC was inserted for every 4 donors. In the second PDSA cycle, 1 CVC was inserted for every 8 apheresis donations. In the third PDSA cycle, no CVC was used for 30 apheresis donations. The targeted stem cell dose was collected successfully in one apheresis session in all donors assigned for PVC access with no complications. A significant reduction of CVC use from 72% to 0% was achieved. This quality improvement project demonstrated that a successful apheresis procedure can be achieved easily and safely in the majority of PBSC donors preventing the potential adverse events associated with CVCs. The interdisciplinary collaboration between the IV team, apheresis and clinical hematology teams was paramount to optimize the safe care of donors. British Publishing Group 2017-04-28 /pmc/articles/PMC5411715/ /pubmed/28469899 http://dx.doi.org/10.1136/bmjquality.u211975.w4817 Text en © 2017, Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/2.0/http://creativecommons.org/licenses/by-nc/2.0/legalcode
spellingShingle BMJ Quality Improvement Programme
Ghazi, Samer
Alaskar, Ahmed
Alzahrani, Mohsen
Damlaj, Moussab
Abuelgasim, Khadega A
Gmati, Giamal
Alshami, Mona
Alshammary, Salman
Al-Surimi, Khaled
Salama, Hind
Alhejazi, Ayman
Jazieh, Abdul-Rahman
Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report
title Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report
title_full Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report
title_fullStr Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report
title_full_unstemmed Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report
title_short Reducing Central Venous Catheter Use in Peripheral Blood Stem Cell Donation: Quality Improvement Report
title_sort reducing central venous catheter use in peripheral blood stem cell donation: quality improvement report
topic BMJ Quality Improvement Programme
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5411715/
https://www.ncbi.nlm.nih.gov/pubmed/28469899
http://dx.doi.org/10.1136/bmjquality.u211975.w4817
work_keys_str_mv AT ghazisamer reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT alaskarahmed reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT alzahranimohsen reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT damlajmoussab reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT abuelgasimkhadegaa reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT gmatigiamal reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT alshamimona reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT alshammarysalman reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT alsurimikhaled reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT salamahind reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT alhejaziayman reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport
AT jaziehabdulrahman reducingcentralvenouscatheteruseinperipheralbloodstemcelldonationqualityimprovementreport