Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels

The data in this article are the simulation results of 1248 cases that were carried out to detect anti-insulation behaviour in the article titled “Anti-insulation mitigation by altering the envelope layers’ configuration” (Idris and Mae, 2017) [1]. These cases are generated by a matrix of 13 climate...

Descripción completa

Detalles Bibliográficos
Autores principales: Idris, Yasin M., Mae, Masayuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5412003/
https://www.ncbi.nlm.nih.gov/pubmed/28491934
http://dx.doi.org/10.1016/j.dib.2017.04.016
_version_ 1783232899269525504
author Idris, Yasin M.
Mae, Masayuki
author_facet Idris, Yasin M.
Mae, Masayuki
author_sort Idris, Yasin M.
collection PubMed
description The data in this article are the simulation results of 1248 cases that were carried out to detect anti-insulation behaviour in the article titled “Anti-insulation mitigation by altering the envelope layers’ configuration” (Idris and Mae, 2017) [1]. These cases are generated by a matrix of 13 climates, 6 envelope layer configurations, 4 occupancy profiles and 4 levels of insulation thickness. The data are concerned with the annual cooling and heating loads of these cases. In addition, the data include the Point of Thermal Inflexion (PTI) values and their anti-insulation pattern, when PTI is found. The PTI values are compiled in a single summary file and supplied as well. All These data are shared via this article where they can be reused in different ways, but mainly for serving researchers that intend to approach anti-insulation behaviour from different points of view.
format Online
Article
Text
id pubmed-5412003
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54120032017-05-10 Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels Idris, Yasin M. Mae, Masayuki Data Brief Data Article The data in this article are the simulation results of 1248 cases that were carried out to detect anti-insulation behaviour in the article titled “Anti-insulation mitigation by altering the envelope layers’ configuration” (Idris and Mae, 2017) [1]. These cases are generated by a matrix of 13 climates, 6 envelope layer configurations, 4 occupancy profiles and 4 levels of insulation thickness. The data are concerned with the annual cooling and heating loads of these cases. In addition, the data include the Point of Thermal Inflexion (PTI) values and their anti-insulation pattern, when PTI is found. The PTI values are compiled in a single summary file and supplied as well. All These data are shared via this article where they can be reused in different ways, but mainly for serving researchers that intend to approach anti-insulation behaviour from different points of view. Elsevier 2017-04-15 /pmc/articles/PMC5412003/ /pubmed/28491934 http://dx.doi.org/10.1016/j.dib.2017.04.016 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Data Article
Idris, Yasin M.
Mae, Masayuki
Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
title Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
title_full Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
title_fullStr Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
title_full_unstemmed Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
title_short Data on anti-insulation detection via Point of Thermal Inflexion (PTI) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
title_sort data on anti-insulation detection via point of thermal inflexion (pti) in 1248 cases; 13 climates, four occupancy profiles, six wall configurations and four insulation levels
topic Data Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5412003/
https://www.ncbi.nlm.nih.gov/pubmed/28491934
http://dx.doi.org/10.1016/j.dib.2017.04.016
work_keys_str_mv AT idrisyasinm dataonantiinsulationdetectionviapointofthermalinflexionptiin1248cases13climatesfouroccupancyprofilessixwallconfigurationsandfourinsulationlevels
AT maemasayuki dataonantiinsulationdetectionviapointofthermalinflexionptiin1248cases13climatesfouroccupancyprofilessixwallconfigurationsandfourinsulationlevels