Cargando…

Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction

To determine the clinical value of radionuclide shuntography in the evaluation of adult hydrocephalic patients with suspected ventriculoperitoneal (V-P) shunt malfunction. All adult patients who underwent Tc-99m diethylenetriamine pentaacetic acid shuntographic scans at Far Eastern Memorial Hospital...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsai, Szu-Ying, Wang, Shan-Ying, Shiau, Yu-Chien, Yang, Lin-Hsue, Wu, Yen-Wen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413273/
https://www.ncbi.nlm.nih.gov/pubmed/28445308
http://dx.doi.org/10.1097/MD.0000000000006767
_version_ 1783233156390846464
author Tsai, Szu-Ying
Wang, Shan-Ying
Shiau, Yu-Chien
Yang, Lin-Hsue
Wu, Yen-Wen
author_facet Tsai, Szu-Ying
Wang, Shan-Ying
Shiau, Yu-Chien
Yang, Lin-Hsue
Wu, Yen-Wen
author_sort Tsai, Szu-Ying
collection PubMed
description To determine the clinical value of radionuclide shuntography in the evaluation of adult hydrocephalic patients with suspected ventriculoperitoneal (V-P) shunt malfunction. All adult patients who underwent Tc-99m diethylenetriamine pentaacetic acid shuntographic scans at Far Eastern Memorial Hospital between August 2005 and December 2015 were included. Shuntographic results were visually evaluated in a simple qualitative manner: prompt flow that reached the peritoneum on 30-minute early images and diffuse peritoneal tracer distribution on 2-hour delayed images were interpreted as nonobstructive shunt flow. Partial dysfunction was diagnosed as scintigraphic findings between no obstruction and complete obstruction (where complete malfunction indicated no peritoneal distribution on delayed images). The results were correlated with the clinical outcomes and surgical results within 30 days. Diagnostic sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were also calculated. A total of 93 scans in 69 patients with suspected V-P shunt malfunction were analyzed. Sixty-two scans were interpreted as abnormal, including complete (n = 26, 41.9) distal obstruction, partial (n = 35, 56.5) distal dysfunction, and miscellaneous (n = 1, 1.6, cerebrospinal fluid leak). The Se and Sp were 83.0% and 55.0%, respectively, and PPV, NPV, and accuracy were all 71.0%. Twenty-five patients (28 scans) underwent surgical revision, and the results were highly concordant with the imaging findings (Se, 92.0%; Sp, 100.0%; PPV, 100.0%; NPV, 60.0%; and accuracy, 92.9%). Radionuclide shuntography provides useful information in adult patients with V-P shunt malfunction and could be used to guide further surgical intervention.
format Online
Article
Text
id pubmed-5413273
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-54132732017-05-05 Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction Tsai, Szu-Ying Wang, Shan-Ying Shiau, Yu-Chien Yang, Lin-Hsue Wu, Yen-Wen Medicine (Baltimore) 5300 To determine the clinical value of radionuclide shuntography in the evaluation of adult hydrocephalic patients with suspected ventriculoperitoneal (V-P) shunt malfunction. All adult patients who underwent Tc-99m diethylenetriamine pentaacetic acid shuntographic scans at Far Eastern Memorial Hospital between August 2005 and December 2015 were included. Shuntographic results were visually evaluated in a simple qualitative manner: prompt flow that reached the peritoneum on 30-minute early images and diffuse peritoneal tracer distribution on 2-hour delayed images were interpreted as nonobstructive shunt flow. Partial dysfunction was diagnosed as scintigraphic findings between no obstruction and complete obstruction (where complete malfunction indicated no peritoneal distribution on delayed images). The results were correlated with the clinical outcomes and surgical results within 30 days. Diagnostic sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were also calculated. A total of 93 scans in 69 patients with suspected V-P shunt malfunction were analyzed. Sixty-two scans were interpreted as abnormal, including complete (n = 26, 41.9) distal obstruction, partial (n = 35, 56.5) distal dysfunction, and miscellaneous (n = 1, 1.6, cerebrospinal fluid leak). The Se and Sp were 83.0% and 55.0%, respectively, and PPV, NPV, and accuracy were all 71.0%. Twenty-five patients (28 scans) underwent surgical revision, and the results were highly concordant with the imaging findings (Se, 92.0%; Sp, 100.0%; PPV, 100.0%; NPV, 60.0%; and accuracy, 92.9%). Radionuclide shuntography provides useful information in adult patients with V-P shunt malfunction and could be used to guide further surgical intervention. Wolters Kluwer Health 2017-04-28 /pmc/articles/PMC5413273/ /pubmed/28445308 http://dx.doi.org/10.1097/MD.0000000000006767 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle 5300
Tsai, Szu-Ying
Wang, Shan-Ying
Shiau, Yu-Chien
Yang, Lin-Hsue
Wu, Yen-Wen
Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
title Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
title_full Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
title_fullStr Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
title_full_unstemmed Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
title_short Clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
title_sort clinical value of radionuclide shuntography by qualitative methods in hydrocephalic adult patients with suspected ventriculoperitoneal shunt malfunction
topic 5300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413273/
https://www.ncbi.nlm.nih.gov/pubmed/28445308
http://dx.doi.org/10.1097/MD.0000000000006767
work_keys_str_mv AT tsaiszuying clinicalvalueofradionuclideshuntographybyqualitativemethodsinhydrocephalicadultpatientswithsuspectedventriculoperitonealshuntmalfunction
AT wangshanying clinicalvalueofradionuclideshuntographybyqualitativemethodsinhydrocephalicadultpatientswithsuspectedventriculoperitonealshuntmalfunction
AT shiauyuchien clinicalvalueofradionuclideshuntographybyqualitativemethodsinhydrocephalicadultpatientswithsuspectedventriculoperitonealshuntmalfunction
AT yanglinhsue clinicalvalueofradionuclideshuntographybyqualitativemethodsinhydrocephalicadultpatientswithsuspectedventriculoperitonealshuntmalfunction
AT wuyenwen clinicalvalueofradionuclideshuntographybyqualitativemethodsinhydrocephalicadultpatientswithsuspectedventriculoperitonealshuntmalfunction