Cargando…

Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain

BACKGROUND: The correction of γ-photon attenuation in PET-MRI remains a critical issue, especially for bone attenuation. This problem is of great importance for brain studies due to the density of the skull. Current techniques for skull attenuation correction (AC) provide indirect estimates of corti...

Descripción completa

Detalles Bibliográficos
Autores principales: Lebon, Vincent, Jan, Sébastien, Fontyn, Yoann, Tiret, Brice, Pottier, Géraldine, Jaumain, Emilie, Valette, Julien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413461/
https://www.ncbi.nlm.nih.gov/pubmed/28466279
http://dx.doi.org/10.1186/s40658-017-0183-6
_version_ 1783233178473857024
author Lebon, Vincent
Jan, Sébastien
Fontyn, Yoann
Tiret, Brice
Pottier, Géraldine
Jaumain, Emilie
Valette, Julien
author_facet Lebon, Vincent
Jan, Sébastien
Fontyn, Yoann
Tiret, Brice
Pottier, Géraldine
Jaumain, Emilie
Valette, Julien
author_sort Lebon, Vincent
collection PubMed
description BACKGROUND: The correction of γ-photon attenuation in PET-MRI remains a critical issue, especially for bone attenuation. This problem is of great importance for brain studies due to the density of the skull. Current techniques for skull attenuation correction (AC) provide indirect estimates of cortical bone density, leading to inaccurate estimates of brain activity. The purpose of this study was to develop an alternate method for bone attenuation correction based on NMR. The proposed approach relies on the detection of hydroxyapatite crystals by zero echo time (ZTE) MRI of (31)P, providing individual and quantitative assessment of bone density. This work presents a proof of concept of this approach. The first step of the method is a calibration experiment to determine the conversion relationship between the (31)P signal and the linear attenuation coefficient μ. Then (31)P-ZTE was performed in vivo in rodent to estimate the μ-map of the skull. (18)F-FDG PET data were acquired in the same animal and reconstructed with three different AC methods: (31)P-based AC, AC neglecting the bone and the gold standard, CT-based AC, used to comparison for the other two methods. RESULTS: The calibration experiment provided a conversion factor of (31)P signal into μ. In vivo (31)P-ZTE made it possible to acquire 3D images of the rat skull. Brain PET images showed underestimation of (18)F activity in peripheral regions close to the skull when AC neglected the bone (as compared with CT-based AC). The use of (31)P-derived μ-map for AC leads to increased peripheral activity, and therefore a global overestimation of brain (18)F activity. CONCLUSIONS: In vivo (31)P-ZTE MRI of hydroxyapatite provides μ-map of the skull, which can be used for attenuation correction of (18)F-FDG PET images. This study is limited by several intrinsic biases associated with the size of the rat brain, which are unlikely to affect human data on a clinical PET-MRI system.
format Online
Article
Text
id pubmed-5413461
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-54134612017-05-15 Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain Lebon, Vincent Jan, Sébastien Fontyn, Yoann Tiret, Brice Pottier, Géraldine Jaumain, Emilie Valette, Julien EJNMMI Phys Original Research BACKGROUND: The correction of γ-photon attenuation in PET-MRI remains a critical issue, especially for bone attenuation. This problem is of great importance for brain studies due to the density of the skull. Current techniques for skull attenuation correction (AC) provide indirect estimates of cortical bone density, leading to inaccurate estimates of brain activity. The purpose of this study was to develop an alternate method for bone attenuation correction based on NMR. The proposed approach relies on the detection of hydroxyapatite crystals by zero echo time (ZTE) MRI of (31)P, providing individual and quantitative assessment of bone density. This work presents a proof of concept of this approach. The first step of the method is a calibration experiment to determine the conversion relationship between the (31)P signal and the linear attenuation coefficient μ. Then (31)P-ZTE was performed in vivo in rodent to estimate the μ-map of the skull. (18)F-FDG PET data were acquired in the same animal and reconstructed with three different AC methods: (31)P-based AC, AC neglecting the bone and the gold standard, CT-based AC, used to comparison for the other two methods. RESULTS: The calibration experiment provided a conversion factor of (31)P signal into μ. In vivo (31)P-ZTE made it possible to acquire 3D images of the rat skull. Brain PET images showed underestimation of (18)F activity in peripheral regions close to the skull when AC neglected the bone (as compared with CT-based AC). The use of (31)P-derived μ-map for AC leads to increased peripheral activity, and therefore a global overestimation of brain (18)F activity. CONCLUSIONS: In vivo (31)P-ZTE MRI of hydroxyapatite provides μ-map of the skull, which can be used for attenuation correction of (18)F-FDG PET images. This study is limited by several intrinsic biases associated with the size of the rat brain, which are unlikely to affect human data on a clinical PET-MRI system. Springer International Publishing 2017-05-02 /pmc/articles/PMC5413461/ /pubmed/28466279 http://dx.doi.org/10.1186/s40658-017-0183-6 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Lebon, Vincent
Jan, Sébastien
Fontyn, Yoann
Tiret, Brice
Pottier, Géraldine
Jaumain, Emilie
Valette, Julien
Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain
title Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain
title_full Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain
title_fullStr Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain
title_full_unstemmed Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain
title_short Using (31)P-MRI of hydroxyapatite for bone attenuation correction in PET-MRI: proof of concept in the rodent brain
title_sort using (31)p-mri of hydroxyapatite for bone attenuation correction in pet-mri: proof of concept in the rodent brain
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413461/
https://www.ncbi.nlm.nih.gov/pubmed/28466279
http://dx.doi.org/10.1186/s40658-017-0183-6
work_keys_str_mv AT lebonvincent using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain
AT jansebastien using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain
AT fontynyoann using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain
AT tiretbrice using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain
AT pottiergeraldine using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain
AT jaumainemilie using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain
AT valettejulien using31pmriofhydroxyapatiteforboneattenuationcorrectioninpetmriproofofconceptintherodentbrain