Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study

AIMS: To determine ten-year failure rates following 36 mm metal-on-metal (MoM) Pinnacle total hip arthroplasty (THA), and identify predictors of failure. PATIENTS AND METHODS: We retrospectively assessed a single-centre cohort of 569 primary 36 mm MoM Pinnacle THAs (all Corail stems) followed up sin...

Descripción completa

Detalles Bibliográficos
Autores principales: Matharu, G. S., Nandra, R. S., Berryman, F., Judge, A., Pynsent, P. B., Dunlop, D. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: British Editorial Society of Bone and Joint Surgery 2017
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413867/
https://www.ncbi.nlm.nih.gov/pubmed/28455467
http://dx.doi.org/10.1302/0301-620X.99B5.BJJ-2016-1232.R1
_version_ 1783233250321235968
author Matharu, G. S.
Nandra, R. S.
Berryman, F.
Judge, A.
Pynsent, P. B.
Dunlop, D. J.
author_facet Matharu, G. S.
Nandra, R. S.
Berryman, F.
Judge, A.
Pynsent, P. B.
Dunlop, D. J.
author_sort Matharu, G. S.
collection PubMed
description AIMS: To determine ten-year failure rates following 36 mm metal-on-metal (MoM) Pinnacle total hip arthroplasty (THA), and identify predictors of failure. PATIENTS AND METHODS: We retrospectively assessed a single-centre cohort of 569 primary 36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012 according to Medicines and Healthcare Products Regulation Agency recommendations. All-cause failure rates (all-cause revision, and non-revised cross-sectional imaging failures) were calculated, with predictors for failure identified using multivariable Cox regression. RESULTS: Failure occurred in 97 hips (17.0%). The ten-year cumulative failure rate was 27.1% (95% confidence interval (CI) 21.6 to 33.7). Primary implantation from 2006 onwards (hazard ratio (HR) 4.30; 95% CI 1.82 to 10.1; p = 0.001) and bilateral MoM hip arthroplasty (HR 1.59; 95% CI 1.03 to 2.46; p = 0.037) predicted failure. The effect of implantation year on failure varied over time. From four years onwards following surgery, hips implanted since 2006 had significantly higher failure rates (eight years 28.3%; 95% CI 23.1 to 34.5) compared with hips implanted before 2006 (eight years 6.3%; 95% CI 2.4 to 15.8) (HR 15.2; 95% CI 2.11 to 110.4; p = 0.007). CONCLUSION: We observed that 36 mm MoM Pinnacle THAs have an unacceptably high ten-year failure rate, especially if implanted from 2006 onwards or in bilateral MoM hip patients. Our findings regarding implantation year and failure support recent concerns about the device manufacturing process. We recommend all patients undergoing implantation since 2006 and those with bilateral MoM hips undergo regular investigation, regardless of symptoms. Cite this article: Bone Joint J 2017;99-B:592–600.
format Online
Article
Text
id pubmed-5413867
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher British Editorial Society of Bone and Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-54138672017-05-12 Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study Matharu, G. S. Nandra, R. S. Berryman, F. Judge, A. Pynsent, P. B. Dunlop, D. J. Bone Joint J Hip AIMS: To determine ten-year failure rates following 36 mm metal-on-metal (MoM) Pinnacle total hip arthroplasty (THA), and identify predictors of failure. PATIENTS AND METHODS: We retrospectively assessed a single-centre cohort of 569 primary 36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012 according to Medicines and Healthcare Products Regulation Agency recommendations. All-cause failure rates (all-cause revision, and non-revised cross-sectional imaging failures) were calculated, with predictors for failure identified using multivariable Cox regression. RESULTS: Failure occurred in 97 hips (17.0%). The ten-year cumulative failure rate was 27.1% (95% confidence interval (CI) 21.6 to 33.7). Primary implantation from 2006 onwards (hazard ratio (HR) 4.30; 95% CI 1.82 to 10.1; p = 0.001) and bilateral MoM hip arthroplasty (HR 1.59; 95% CI 1.03 to 2.46; p = 0.037) predicted failure. The effect of implantation year on failure varied over time. From four years onwards following surgery, hips implanted since 2006 had significantly higher failure rates (eight years 28.3%; 95% CI 23.1 to 34.5) compared with hips implanted before 2006 (eight years 6.3%; 95% CI 2.4 to 15.8) (HR 15.2; 95% CI 2.11 to 110.4; p = 0.007). CONCLUSION: We observed that 36 mm MoM Pinnacle THAs have an unacceptably high ten-year failure rate, especially if implanted from 2006 onwards or in bilateral MoM hip patients. Our findings regarding implantation year and failure support recent concerns about the device manufacturing process. We recommend all patients undergoing implantation since 2006 and those with bilateral MoM hips undergo regular investigation, regardless of symptoms. Cite this article: Bone Joint J 2017;99-B:592–600. British Editorial Society of Bone and Joint Surgery 2017-05-01 /pmc/articles/PMC5413867/ /pubmed/28455467 http://dx.doi.org/10.1302/0301-620X.99B5.BJJ-2016-1232.R1 Text en ©2017 Matharu et al This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Hip
Matharu, G. S.
Nandra, R. S.
Berryman, F.
Judge, A.
Pynsent, P. B.
Dunlop, D. J.
Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
title Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
title_full Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
title_fullStr Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
title_full_unstemmed Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
title_short Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
title_sort risk factors for failure of the 36 mm metal-on-metal pinnacle total hip arthroplasty system: a retrospective single-centre cohort study
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5413867/
https://www.ncbi.nlm.nih.gov/pubmed/28455467
http://dx.doi.org/10.1302/0301-620X.99B5.BJJ-2016-1232.R1
work_keys_str_mv AT matharugs riskfactorsforfailureofthe36mmmetalonmetalpinnacletotalhiparthroplastysystemaretrospectivesinglecentrecohortstudy
AT nandrars riskfactorsforfailureofthe36mmmetalonmetalpinnacletotalhiparthroplastysystemaretrospectivesinglecentrecohortstudy
AT berrymanf riskfactorsforfailureofthe36mmmetalonmetalpinnacletotalhiparthroplastysystemaretrospectivesinglecentrecohortstudy
AT judgea riskfactorsforfailureofthe36mmmetalonmetalpinnacletotalhiparthroplastysystemaretrospectivesinglecentrecohortstudy
AT pynsentpb riskfactorsforfailureofthe36mmmetalonmetalpinnacletotalhiparthroplastysystemaretrospectivesinglecentrecohortstudy
AT dunlopdj riskfactorsforfailureofthe36mmmetalonmetalpinnacletotalhiparthroplastysystemaretrospectivesinglecentrecohortstudy