Cargando…

Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis

BACKGROUND: Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the we...

Descripción completa

Detalles Bibliográficos
Autores principales: Ayali, Aysa, Bilginaylar, Kani
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414147/
https://www.ncbi.nlm.nih.gov/pubmed/28464946
http://dx.doi.org/10.1186/s13005-017-0139-z
_version_ 1783233306343505920
author Ayali, Aysa
Bilginaylar, Kani
author_facet Ayali, Aysa
Bilginaylar, Kani
author_sort Ayali, Aysa
collection PubMed
description BACKGROUND: Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the weakend mandibular bone decreases the strength of the bone and may lead to fractures either during or after implant placement. The aim of this three dimensional finite element analysis (3D FEA) study was to evaluate the biomechanical effects of implant diameter in case of facial trauma (2000 N) to an edentulous atrophic mandible with two implant supported overdenture. METHODS: Three 3D FEA models were simulated; Model 1 (M1) is edentulous atrophic mandible, Model 2 (M2), 3.5x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible, Model 3 (M3), 4.3x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible. RESULTS: In M1 and M2 highest stress levels were observed in condylar neck, whereas highest stress values in M3 were calculated in symphyseal area. CONCLUSIONS: To reduce the risk of bone fracture and to preserve biomechanical behavior of the atrophic mandible from frontal traumatic loads, implants should be inserted monocortically into spongious bone of lateral incisors area.
format Online
Article
Text
id pubmed-5414147
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54141472017-05-03 Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis Ayali, Aysa Bilginaylar, Kani Head Face Med Research BACKGROUND: Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the weakend mandibular bone decreases the strength of the bone and may lead to fractures either during or after implant placement. The aim of this three dimensional finite element analysis (3D FEA) study was to evaluate the biomechanical effects of implant diameter in case of facial trauma (2000 N) to an edentulous atrophic mandible with two implant supported overdenture. METHODS: Three 3D FEA models were simulated; Model 1 (M1) is edentulous atrophic mandible, Model 2 (M2), 3.5x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible, Model 3 (M3), 4.3x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible. RESULTS: In M1 and M2 highest stress levels were observed in condylar neck, whereas highest stress values in M3 were calculated in symphyseal area. CONCLUSIONS: To reduce the risk of bone fracture and to preserve biomechanical behavior of the atrophic mandible from frontal traumatic loads, implants should be inserted monocortically into spongious bone of lateral incisors area. BioMed Central 2017-05-02 /pmc/articles/PMC5414147/ /pubmed/28464946 http://dx.doi.org/10.1186/s13005-017-0139-z Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ayali, Aysa
Bilginaylar, Kani
Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
title Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
title_full Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
title_fullStr Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
title_full_unstemmed Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
title_short Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
title_sort evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3d finite element analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414147/
https://www.ncbi.nlm.nih.gov/pubmed/28464946
http://dx.doi.org/10.1186/s13005-017-0139-z
work_keys_str_mv AT ayaliaysa evaluatingthebiomechanicaleffectsofimplantdiameterincaseoffacialtraumatoanedentulousatrophicmandiblea3dfiniteelementanalysis
AT bilginaylarkani evaluatingthebiomechanicaleffectsofimplantdiameterincaseoffacialtraumatoanedentulousatrophicmandiblea3dfiniteelementanalysis