Cargando…
Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis
BACKGROUND: Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the we...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414147/ https://www.ncbi.nlm.nih.gov/pubmed/28464946 http://dx.doi.org/10.1186/s13005-017-0139-z |
_version_ | 1783233306343505920 |
---|---|
author | Ayali, Aysa Bilginaylar, Kani |
author_facet | Ayali, Aysa Bilginaylar, Kani |
author_sort | Ayali, Aysa |
collection | PubMed |
description | BACKGROUND: Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the weakend mandibular bone decreases the strength of the bone and may lead to fractures either during or after implant placement. The aim of this three dimensional finite element analysis (3D FEA) study was to evaluate the biomechanical effects of implant diameter in case of facial trauma (2000 N) to an edentulous atrophic mandible with two implant supported overdenture. METHODS: Three 3D FEA models were simulated; Model 1 (M1) is edentulous atrophic mandible, Model 2 (M2), 3.5x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible, Model 3 (M3), 4.3x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible. RESULTS: In M1 and M2 highest stress levels were observed in condylar neck, whereas highest stress values in M3 were calculated in symphyseal area. CONCLUSIONS: To reduce the risk of bone fracture and to preserve biomechanical behavior of the atrophic mandible from frontal traumatic loads, implants should be inserted monocortically into spongious bone of lateral incisors area. |
format | Online Article Text |
id | pubmed-5414147 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54141472017-05-03 Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis Ayali, Aysa Bilginaylar, Kani Head Face Med Research BACKGROUND: Rehabilitation using an implant supported overdenture with two implants inserted in the interforaminal region is the easiest and currently accepted treatment modality to increase prosthetic stabilization and patient satisfaction in edentulous patients. The insertion of implants to the weakend mandibular bone decreases the strength of the bone and may lead to fractures either during or after implant placement. The aim of this three dimensional finite element analysis (3D FEA) study was to evaluate the biomechanical effects of implant diameter in case of facial trauma (2000 N) to an edentulous atrophic mandible with two implant supported overdenture. METHODS: Three 3D FEA models were simulated; Model 1 (M1) is edentulous atrophic mandible, Model 2 (M2), 3.5x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible, Model 3 (M3), 4.3x11.5 mm implants were inserted into lateral incisors area of same edentulous atrophic mandible. RESULTS: In M1 and M2 highest stress levels were observed in condylar neck, whereas highest stress values in M3 were calculated in symphyseal area. CONCLUSIONS: To reduce the risk of bone fracture and to preserve biomechanical behavior of the atrophic mandible from frontal traumatic loads, implants should be inserted monocortically into spongious bone of lateral incisors area. BioMed Central 2017-05-02 /pmc/articles/PMC5414147/ /pubmed/28464946 http://dx.doi.org/10.1186/s13005-017-0139-z Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Ayali, Aysa Bilginaylar, Kani Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis |
title | Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis |
title_full | Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis |
title_fullStr | Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis |
title_full_unstemmed | Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis |
title_short | Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis |
title_sort | evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3d finite element analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414147/ https://www.ncbi.nlm.nih.gov/pubmed/28464946 http://dx.doi.org/10.1186/s13005-017-0139-z |
work_keys_str_mv | AT ayaliaysa evaluatingthebiomechanicaleffectsofimplantdiameterincaseoffacialtraumatoanedentulousatrophicmandiblea3dfiniteelementanalysis AT bilginaylarkani evaluatingthebiomechanicaleffectsofimplantdiameterincaseoffacialtraumatoanedentulousatrophicmandiblea3dfiniteelementanalysis |