Cargando…
Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay
BACKGROUND: The conventional and widely used enzyme-linked immunosorbent assays (ELISA), due to specificity and high-sensitivity, were suitable in vitro diagnosis. But enzymes are vulnerable to the external conditions, and the complex operation steps limit its application. Semiconductor quantum dots...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414212/ https://www.ncbi.nlm.nih.gov/pubmed/28464873 http://dx.doi.org/10.1186/s12951-017-0267-4 |
_version_ | 1783233323268571136 |
---|---|
author | Lv, Yanbing Wu, Ruili Feng, Kunrui Li, Jinjie Mao, Qing Yuan, Hang Shen, Huaibin Chai, Xiangdong Li, Lin Song |
author_facet | Lv, Yanbing Wu, Ruili Feng, Kunrui Li, Jinjie Mao, Qing Yuan, Hang Shen, Huaibin Chai, Xiangdong Li, Lin Song |
author_sort | Lv, Yanbing |
collection | PubMed |
description | BACKGROUND: The conventional and widely used enzyme-linked immunosorbent assays (ELISA), due to specificity and high-sensitivity, were suitable in vitro diagnosis. But enzymes are vulnerable to the external conditions, and the complex operation steps limit its application. Semiconductor quantum dots have been successfully used in biological and medical research due to the high photoluminescence and high resistance to photobleaching. In this study, we have developed a novel quantum dot-labeled immunosorbent assay for rapid disease detection of C-reactive protein (CRP). RESULTS: The assay for the detection of CRP can provide a wide analytical range of 1.56–400 ng/mL with the limit of detection (LOD) = 0.46 ng/mL and the limit of quantification = 1.53 ng/mL. The precision of the assay has been confirmed for low coefficient of variation, less than 10% (intra-assay) and less than 15% (inter-assay). The accuracy of assay meets the requirements with the recoveries of 95.4–105.7%. Furthermore, clinical samples have been collected and used for correlation analysis between this FLISA and gold standard Roche immunoturbidimetry. It shows excellent accurate concordance and the correlation coefficient value (R) is as high as 0.989 (n = 34). CONCLUSIONS: This in vitro quantum dot-based detection method offers a lower LOD and a wide liner detection range than ELISA. The total reaction time is only 50 min, which is much shorter than the commercialization ELISA (about 120 min). All of the results show that a convenient, sensitive, and accurate fluorescence-linked immunosorbent assay method has been well established for the detection of CRP samples. Therefore, this method has immense potential for the development of rapid and cost-effective in vitro diagnostic kits. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12951-017-0267-4) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5414212 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54142122017-05-03 Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay Lv, Yanbing Wu, Ruili Feng, Kunrui Li, Jinjie Mao, Qing Yuan, Hang Shen, Huaibin Chai, Xiangdong Li, Lin Song J Nanobiotechnology Research BACKGROUND: The conventional and widely used enzyme-linked immunosorbent assays (ELISA), due to specificity and high-sensitivity, were suitable in vitro diagnosis. But enzymes are vulnerable to the external conditions, and the complex operation steps limit its application. Semiconductor quantum dots have been successfully used in biological and medical research due to the high photoluminescence and high resistance to photobleaching. In this study, we have developed a novel quantum dot-labeled immunosorbent assay for rapid disease detection of C-reactive protein (CRP). RESULTS: The assay for the detection of CRP can provide a wide analytical range of 1.56–400 ng/mL with the limit of detection (LOD) = 0.46 ng/mL and the limit of quantification = 1.53 ng/mL. The precision of the assay has been confirmed for low coefficient of variation, less than 10% (intra-assay) and less than 15% (inter-assay). The accuracy of assay meets the requirements with the recoveries of 95.4–105.7%. Furthermore, clinical samples have been collected and used for correlation analysis between this FLISA and gold standard Roche immunoturbidimetry. It shows excellent accurate concordance and the correlation coefficient value (R) is as high as 0.989 (n = 34). CONCLUSIONS: This in vitro quantum dot-based detection method offers a lower LOD and a wide liner detection range than ELISA. The total reaction time is only 50 min, which is much shorter than the commercialization ELISA (about 120 min). All of the results show that a convenient, sensitive, and accurate fluorescence-linked immunosorbent assay method has been well established for the detection of CRP samples. Therefore, this method has immense potential for the development of rapid and cost-effective in vitro diagnostic kits. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12951-017-0267-4) contains supplementary material, which is available to authorized users. BioMed Central 2017-05-02 /pmc/articles/PMC5414212/ /pubmed/28464873 http://dx.doi.org/10.1186/s12951-017-0267-4 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Lv, Yanbing Wu, Ruili Feng, Kunrui Li, Jinjie Mao, Qing Yuan, Hang Shen, Huaibin Chai, Xiangdong Li, Lin Song Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay |
title | Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay |
title_full | Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay |
title_fullStr | Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay |
title_full_unstemmed | Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay |
title_short | Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay |
title_sort | highly sensitive and accurate detection of c-reactive protein by cdse/zns quantum dot-based fluorescence-linked immunosorbent assay |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414212/ https://www.ncbi.nlm.nih.gov/pubmed/28464873 http://dx.doi.org/10.1186/s12951-017-0267-4 |
work_keys_str_mv | AT lvyanbing highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT wuruili highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT fengkunrui highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT lijinjie highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT maoqing highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT yuanhang highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT shenhuaibin highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT chaixiangdong highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay AT lilinsong highlysensitiveandaccuratedetectionofcreactiveproteinbycdseznsquantumdotbasedfluorescencelinkedimmunosorbentassay |