Cargando…
Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma
BACKGROUND: To investigate the influence of region of interest (ROI) size on tumor apparent diffusion coefficient (ADC) measurements in pancreatic cancer. METHODS: The study population consisted of 64 patients with pathologically proved pancreatic ductal adenocarcinomas (PDACs), who underwent preope...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414294/ https://www.ncbi.nlm.nih.gov/pubmed/28464866 http://dx.doi.org/10.1186/s40644-017-0116-6 |
_version_ | 1783233344786399232 |
---|---|
author | Ma, Chao Guo, Xiaoyu Liu, Li Zhan, Qian Li, Jing Zhu, Chengcheng Wang, Li Zhang, Jing Fang, Xu Qu, Jianxun Chen, Shiyue Shao, Chengwei Lu, Jian-ping |
author_facet | Ma, Chao Guo, Xiaoyu Liu, Li Zhan, Qian Li, Jing Zhu, Chengcheng Wang, Li Zhang, Jing Fang, Xu Qu, Jianxun Chen, Shiyue Shao, Chengwei Lu, Jian-ping |
author_sort | Ma, Chao |
collection | PubMed |
description | BACKGROUND: To investigate the influence of region of interest (ROI) size on tumor apparent diffusion coefficient (ADC) measurements in pancreatic cancer. METHODS: The study population consisted of 64 patients with pathologically proved pancreatic ductal adenocarcinomas (PDACs), who underwent preoperative magnetic resonance imaging (MRI) examinations including diffusion-weighted imaging (DWI). The tumor ADCs were measured by two independent readers using six round ROIs with sizes ranging from 20 to 214 mm(2) (9 to 97 pixels) in both the six separate measurements. The intra- and inter-observer variabilities were analyzed by using the coefficient of variance (CV), the interclass correlation coefficient (ICC) and Bland-Altman analysis. The mean ADCs measured with the 6 different-sized ROIs were compared using one-way repeated analysis of variance. The sample sizes were calculated by using 80% power and a 5% significance level to detect 10 to 25% changes in ADC measurements. RESULTS: The largest ROI (ROI(214)) yielded the best intra-observer repeatability (CV, 6.3%; ICC, 0.93) and inter-observer reproducibility (CV, 10.1%; ICC, 0.84). The mean differences in ADC measurements ± limits of agreement between the two readers were (0.06 ± 0.47) × 10(−3) mm(2) for ROI(20), (0.08 ± 0.46) × 10(−3) mm(2) for ROI(46), (0.05 ± 0.37) × 10(−3) mm(2) for ROI(82), (0.07 ± 0.42) × 10(−3) mm(2) for ROI(115), (0.05 ± 0.43) × 10(−3) mm(2) for ROI(152) and (−0.02 ± 0.29) × 10(−3) mm(2) for ROI(214). CONCLUSIONS: ROI size had a considerable influence on the ADC measurements of PDACs. |
format | Online Article Text |
id | pubmed-5414294 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54142942017-05-03 Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma Ma, Chao Guo, Xiaoyu Liu, Li Zhan, Qian Li, Jing Zhu, Chengcheng Wang, Li Zhang, Jing Fang, Xu Qu, Jianxun Chen, Shiyue Shao, Chengwei Lu, Jian-ping Cancer Imaging Research Article BACKGROUND: To investigate the influence of region of interest (ROI) size on tumor apparent diffusion coefficient (ADC) measurements in pancreatic cancer. METHODS: The study population consisted of 64 patients with pathologically proved pancreatic ductal adenocarcinomas (PDACs), who underwent preoperative magnetic resonance imaging (MRI) examinations including diffusion-weighted imaging (DWI). The tumor ADCs were measured by two independent readers using six round ROIs with sizes ranging from 20 to 214 mm(2) (9 to 97 pixels) in both the six separate measurements. The intra- and inter-observer variabilities were analyzed by using the coefficient of variance (CV), the interclass correlation coefficient (ICC) and Bland-Altman analysis. The mean ADCs measured with the 6 different-sized ROIs were compared using one-way repeated analysis of variance. The sample sizes were calculated by using 80% power and a 5% significance level to detect 10 to 25% changes in ADC measurements. RESULTS: The largest ROI (ROI(214)) yielded the best intra-observer repeatability (CV, 6.3%; ICC, 0.93) and inter-observer reproducibility (CV, 10.1%; ICC, 0.84). The mean differences in ADC measurements ± limits of agreement between the two readers were (0.06 ± 0.47) × 10(−3) mm(2) for ROI(20), (0.08 ± 0.46) × 10(−3) mm(2) for ROI(46), (0.05 ± 0.37) × 10(−3) mm(2) for ROI(82), (0.07 ± 0.42) × 10(−3) mm(2) for ROI(115), (0.05 ± 0.43) × 10(−3) mm(2) for ROI(152) and (−0.02 ± 0.29) × 10(−3) mm(2) for ROI(214). CONCLUSIONS: ROI size had a considerable influence on the ADC measurements of PDACs. BioMed Central 2017-05-02 /pmc/articles/PMC5414294/ /pubmed/28464866 http://dx.doi.org/10.1186/s40644-017-0116-6 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Ma, Chao Guo, Xiaoyu Liu, Li Zhan, Qian Li, Jing Zhu, Chengcheng Wang, Li Zhang, Jing Fang, Xu Qu, Jianxun Chen, Shiyue Shao, Chengwei Lu, Jian-ping Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma |
title | Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma |
title_full | Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma |
title_fullStr | Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma |
title_full_unstemmed | Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma |
title_short | Effect of region of interest size on ADC measurements in pancreatic adenocarcinoma |
title_sort | effect of region of interest size on adc measurements in pancreatic adenocarcinoma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414294/ https://www.ncbi.nlm.nih.gov/pubmed/28464866 http://dx.doi.org/10.1186/s40644-017-0116-6 |
work_keys_str_mv | AT machao effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT guoxiaoyu effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT liuli effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT zhanqian effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT lijing effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT zhuchengcheng effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT wangli effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT zhangjing effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT fangxu effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT qujianxun effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT chenshiyue effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT shaochengwei effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma AT lujianping effectofregionofinterestsizeonadcmeasurementsinpancreaticadenocarcinoma |